background image

 

 

PARTS LOCATION

 

5

 

3

 

ASSEMBLE SIDE 

PANELS

 

1

 

LAY FOUNDATION

 

2

 

ASSEMBLE DOOR

 

QUICK OVERVIEW

 

Top Plate Back

 

Side Wall Sheets

 

Barge Flashing

 

Spouting

 

Roof Sheets 

 

3  1Pan Sheet

 

Top Plate Side

 

Top Plate Front

 

Bottom Plate Front

 

Bottom Plate Side

 

Back Wall Sheets

 

3  1Pan Sheet

 

Front Wall Sheets

 

Door Jambs

 

Front 1Pan Wall Sheet

 

Door Sheets

 

Door Side Flashing

 

Hinge

 

Door Brace

 

Door Top/Bottom 

 

Ridge Flashing

 

5

 

ASSEMBLE FRONT 

PANEL

 

6

 

ASSEMBLE WALLS

 

7

 

ASSEMBLE ROOF

 

8

 

SECURE SHED

 

4

 

ASSEMBLE BACK 

PANEL

 

Padbolt Support 

 

Summary of Contents for GS63

Page 1: ...ASSEMBLY INSTRUCTIONS GS63 BASE SIZE 1 690m x 1 020m...

Page 2: ......

Page 3: ...ocess needs to be adhered to to qualify for the steel warranty of your Duratuf Guardian shed Wash all surfaces annually using a hose and soft nylon brush Within 2 km of coast wash every 3 months as ab...

Page 4: ...nt Wall 1 890m 1 Back Wall 1 950m 3 Back Wall 1 Pan 1 950m 1 Side Wall Angle 1 905m 2 Side Wall Angle 1 935m 2 Roof 1 110m 3 Roof 1 Pan 1 110m 1 Door Sheet Narrow 1 850m 2 Door Sides 1 850m 2 Door Jam...

Page 5: ...MBER DESCRIPTION QTY DIAGRAM CHECKED Front Back Bottom Plates H4 Green 1 690 m 2 Front Back Top Plate H1 Red 1 690 m 2 Side Wall Bottom Plates H4 Green 1 020 m 2 Side Wall Top Plates H1 Red 1 022m 2 R...

Page 6: ...heets 1Pan Sheet Top Plate Side Top Plate Front Bottom Plate Front Bottom Plate Side Back Wall Sheets 3 Sheets 1Pan Sheet Front Wall Sheets Door Jambs Front 1Pan Wall Sheet Door Sheets Door Side Flash...

Page 7: ...hrough from underneath During construction you may raise the bottom timber plate to allow the wall cladding to protrude 20mm below the bottom plate This will stop water flowing between the bottom plat...

Page 8: ...emble door as shown ensuring narrow face of flashing is on the front as per fig 1 STEP 4 On the back of the door place door braces in posi tion as shown in fig 4 Ensure that the top and bottom ends of...

Page 9: ...Rivet sheets together on overlaps as shown STEP 3 Nail wall sheets to the Top Plate at each end making sure that the top of the sheets are flush with the top of the Top Plate and the sides of the wal...

Page 10: ...her on overlaps as shown STEP 3 Nail the wall sheets to the Top Plate at each end making sure that the top of the sheets are flush with the top of the Top Plate and that the sides of the wall sheets o...

Page 11: ...IMBER BASE PLATE READ THE FOLLOWING For sheds with Raised Base Plate option only see page 6 deduct 30mm from measurement shown between Top and Bottom Plates on all wall panels so cladding protrudes 20...

Page 12: ...h the second Side Panel ensuring that the Side Panel overlaps the Back Wall Panel STEP 3 Stand up the Front Wall Panel Ensure that the Front Wall Sheets overlap the Side Wall Sheets Using 8 x 40mm scr...

Page 13: ...Using 4 x 50mm Clouts predrill and nail the Roof Sheets to the Top Plates through the ribs at each corner ensuring ribs on the Roof Sheets line up with ribs on the Wall Sheets fig 2 STEP 3 Ensure the...

Page 14: ...onry drill bit is required FITTING A GUARDIAN FLOOR KIT OPTIONAL Position the Floor Joists centrally between the side Base Plates and skew nail each end with two 75mm nails Check that the shed is sitt...

Page 15: ......

Page 16: ...less than 200g m2 as published by Branz Warranty certificate being returned to manufacturer within 21 days of purchase together with proof of purchase This warranty does not cover the following Faste...

Reviews: