ERROR MESSAGES & TROUBLESHOOTING GUIDE
1.
INPUT LOW:
DC Input Voltage is below 12V. Readjust
DC power supply to 12V or higher. 13V is recommended.
2.
INPUT OVER 17V:
DC input voltage is above 17V.
Readjust DC power supply to below 17V. 13V is
recommended.
3.
CELLS/TYPE ERROR:
Lithium pack balance lead is
not connected. Connect lithium pack balance lead and
retry charge process. Check charge settings and be
sure they match battery specifi cations.
4.
OPEN CIRCUIT:
Main battery charge lead is not
connected. Connect battery to charge.
5.
WRONG +/- OR OPEN:
Battery is connected backwards
to the charger’s output. Reverse the connection and
retry charge process.
6.
OUTPUT NO BAT:
NiCd/NiMH battery became
disconnected during charge process. Reconnect
battery and retry charge.