ELECTRICAL SPECIFICATION

• 

Accuracy is given ± (% of r number of least significant digits) for one year, 

at 23°C ± 5°C RH<75%.

DC VOLTAGE

Range

Resolution

Accuracy

200mV

0.1mV

± (0.5% + 3 digits)

2V

1mV

± (0.8% + 2 digits)

20V

10mV

200V

0.1V

600V

1V

± (1.0% + 2 digits)

•  Input impedance: 10MΩ.

AC VOLTAGE

Range

Resolution

Accuracy

2V

1mV

± (0.8% + 3 digits)

20V

10mV

200V

0.1V

600V

1V

± (1.2% + 3 digits)

•  Input impedance: 10MΩ.

•  Frequency range: 40 ~ 400Hz.

DC CURRENT

Range

Resolution

Accuracy

2mA

1µA

± (1.8% + 2 digits)

20mA

10µA

± (1.8% + 2 digits)

200mA

0.1mA

± (2.0% + 2 digits)

10A

10mA

± (2.0% + 10 digits)

•  Measuring voltage drop: 200mV.

AC CURRENT

Range

Resolution

Accuracy

2mA

1µA

± (2.0% + 3 digits)

20mA

10µA

± (2.0% + 3 digits)

200mA

0.1mA

± (2.0% + 5 digits)

10A

10mA

± (2.5% + 10 digits)

•  Measuring voltage drop: 200mV.

•  Frequency range: 40 ~ 400Hz.

TEMPERATURE

Range

Resolution

Accuracy

-40°C ~ 400°C

1°C

± (1.0% + 4)

400°C ~ 1000°C

± (1.5% + 15)

•  With K-type thermocouple.