Resistance

Range

Resolution

Accuracy

200Ω

0.1Ω

± (1.0% r 3)

2kΩ

0.001kΩ

20kΩ

0.01kΩ

200kΩ

0.1kΩ

2MΩ

0.001MΩ

20MΩ

0.01MΩ

± (1.2% r 15)

• 

Input protection: 

Maximum DC or AC 

600V RMS

• 

Input protection: Maximum DC or AC 600V RMS.

CLEANING & MAINTENANCE

• 

Clean the outer cabinet of the instrument with a clean, damp cloth and a small 

amount of mild detergent.

• 

Do not use any chemicals, abrasives or solvents that could damage the meter.

Diode

Function

Range

Resolution

Test Environment

Diode test

1V

0.001V

Testing current: about 1mA; open circuit 

voltage: about 2.8V.

The display will show the approximate 

value of the diode forward voltage drop.

Buzzer On/Off

Function

Description

Test Environment

When the built-in buzzer sounds, 

the measured resistance is no 

more than about 50Ω.

Testing current: about 1mA; open 

circuit voltage: about 2.8V.

 

• 

Input protection: Maximum DC or AC 600V RMS.

REPLACING THE BATTERIES

• 

Turn off the power supply and disconnect the probe from the measured circuit.

• 

Loosen the screws used for fixing the battery cover and remove the battery cover.

• 

Remove the old batteries and replace with new ones.

• 

Mount the battery cover and and tighten the screws.

RECYCLING INFORMATION

This symbol indicates that separate collection of Waste Electrical and 

Electronic Equipment (WEEE) or waste batteries is required. Do not dispose 

of these items with general household waste. Separate for the treatment, 

recovery and recycling of the materials used. Waste batteries can be returned 

to any waste battery recycling point which are provided by most battery 

retailers. Contact your local authority for details of the battery and WEEE 

recycling schemes available in your area.

Made in China. PR2 9PP

V 1.0

Summary of Contents for D03127

Page 1: ...1 MODEL D03127 Digital Multimeter Pen Type...

Page 2: ...rview 4 Measurement Operation 5 AC DC Voltage Measurement 5 AC DC Current Measurement 5 Resistance Measurement 6 Diode Measurement 6 Connectivity Test 6 Non contact Voltage Detection 6 General Technic...

Page 3: ...instrument around explosive gas steam or in a wet environment When measuring connect the zero ground line first then connect the live wire When disconnecting ensure you disconnect the live wire first...

Page 4: ...unit is turned the default mode is automatic range on or the function is switched the instrument displays AUTO symbol The operations of entering or quitting manual range are as follows In automatic r...

Page 5: ...screen When measuring DC current the display also shows the voltage polarity of the red probe test point Note If OL is displayed it means that the instrument exceeds the measurement range of the instr...

Page 6: ...50 the buzzer will sound Warning Firstly disconnect the power supply of the circuit to be measured and fully discharge all high voltage capacitors After completing all measurements always disconnect t...

Page 7: ...humidity is no more than 80 DC Voltage Range Resolution Accuracy 200mV 0 1mV 0 5 reading 3 2V 0 001V 20V 0 01V 200V 0 1V 600V 1V 0 8 reading 5 Input impedance 10M Maximum input voltage DC or AC 600V...

Page 8: ...ore than about 50 Testing current about 1mA open circuit voltage about 2 8V Input protection Maximum DC or AC 600V RMS REPLACING THE BATTERIES Turn off the power supply and disconnect the probe from t...

Reviews: