5.2

 

Power Unit Operation 

5.2.1

 

Plug in power unit. 

5.2.2

 

Press ON switch to run the motor and to A

dvance

 the cylinder.  

5.2.3

 

Release ON switch to stop the motor and automatically R

etract

 the cylinder. 

Note – the cylinder retraction will occur after a slight pause because this power 
unit is fitted with a pressure valve rather than a solenoid valve. 

5.3

 

Relief Valve Adjustment 

All power units contain a factory set internal relief valve to prevent over-pressurisation 
of the system. A deck mounted adjustable pressure relief valve is also included and can 
be set to lower working pressures (see Item 5, shown in Section 8.1 – High Level 
Description of Parts). 

Turn the adjusting screw a few turns (counter-clockwise) to decrease the pressure 
setting to the desired level. Clockwise rotation of the adjusting screw will increase 
pressure. 

6.0

 

Maintenance 

 

IMPORTANT: 

 

 

Disconnect power supply before disassembly or repair 

 

 

Check oil level regularly 

 

 

Use only good quality hydraulic fluid. 

Do NOT

 use brake fluid, transmission fluid, 

turbine oil, motor oil, alcohol, glycerine etc. Use of anything other than good quality 
hydraulic oil will void warranty and damage the power unit, hose, and application. We 
recommend Durapac Hydraulic Oil or equivalent 

 

 

Equipment must only be serviced by a qualified hydraulic technician. For repair service, 
contact your local Durapac authorised service centre 

 

 

Damage to hydraulic hoses may not be detected during visual inspections. For this 
reason, Durapac recommends that hydraulic hoses be replaced on a regular basis 

 

 

Tighten connections as needed. Use non-hardening pipe thread compound when 
servicing connections 

Dirt, sand, etc. will quickly ruin any hydraulic system.  Ensure that couplings are clean and 
free of foreign matter. After each use, clean couplings and attach dust caps. 

Maintenance is required when wear or leakage is noticed. Periodically inspect all 
components to detect any problem that may require service and maintenance.  

6.1

 

Adding Hydraulic Fluid 

 

WARNING: Always add oil with cylinders fully retracted (or extended, if pull cylinders) or 
the system will contain more oil than the reservoir can hold 

6.1.1

 

Depressurise and disconnect hydraulic hose from application/cylinder. 

Summary of Contents for SPES3502AR

Page 1: ...86 Granite Street GEEBUNG QLD 4034 Australia sales absoluteequipment com au Phone 61 7 3865 4006 Fax 61 7 3102 6288 Maximum Operating Pressure 700 bar Instruction Manual 035 Series Auto 2 Speed Compact Electric Power Unit SPES3502AR ...

Page 2: ...laced with Durapac authorised replacement parts only Any power unit that appears to be damaged in any way is worn leaking or operates abnormally should be removed from service immediately until such time as repairs can be made Any power unit that has been or suspected to have been subject to a shock load should be removed from service immediately until inspected by a Durapac authorised service cen...

Page 3: ... cautions and warnings before starting to operate the equipment The operator is responsible for this activity towards other persons Do NOT lift hydraulic equipment by the hoses or couplers Use the carrying handle or other means of safe transport Hydraulic equipment must only be serviced by a qualified hydraulic technician For repair service contact the Durapac authorised service centre in your are...

Page 4: ...d flow within the hose is blocked or reduced Periodically inspect the hose for wear Hose material and coupler seals must be compatible with the hydraulic fluid used Hoses also must not come in contact with corrosive materials such as battery acid creosote impregnated objects and wet paint Never paint a coupler or hose FAILURE TO HEED THESE WARNINGS MAY RESULT IN PERSONAL INJURY AS WELL AS PROPERTY...

Page 5: ...rom the System in the Maintenance Section 5 0 Operation IMPORTANT Always monitor pressure load or position using suitable equipment Pressure may be monitored by means of an optional manifold and gauge Correct application position can only be determined by the operator of the equipment Never set the relief valve to a higher pressure than the maximum rated pressure of the power unit Higher settings ...

Page 6: ...aulic fluid Do NOT use brake fluid transmission fluid turbine oil motor oil alcohol glycerine etc Use of anything other than good quality hydraulic oil will void warranty and damage the power unit hose and application We recommend Durapac Hydraulic Oil or equivalent Equipment must only be serviced by a qualified hydraulic technician For repair service contact your local Durapac authorised service ...

Page 7: ...r level than the power unit reservoir 6 2 4 Using the pendant extend and retract the cylinder several times without putting a load on the system Air should be released from the system 6 2 5 If oil still cannot be delivered to develop pressure place the power unit horizontally as shown below and push the rubber lining through the 8mm diameter hole on the tank cover end with a round ended rod 30mm o...

Page 8: ...ically Fig 3 Carbon Brush Replacement 6 4 1 Remove rubber caps x 2 6 4 2 Use a screw driver to loosen and remove inside fitting screws so that carbon brushes can be taken out 6 4 3 Replace with new carbon brushes fix the screws and rubber caps 6 5 Storage 6 5 1 When not in use depressurise and disconnect the power unit from the application 6 5 2 Wipe clean thoroughly and store in a clean dry envir...

Page 9: ...l is over heating Oil viscosity is too high Refer to 6 3 Changing Hydraulic Fluid Refill with a good quality hydraulic oil High pressure leakage on upper pressure plate Tighten plug Low fluid level in power unit reservoir Refer to 6 1 Adding Hydraulic Fluid Fill and bleed the system Power unit runs but will not pump oil Power unit is not primed Run power unit a few minutes tipping from side to sid...

Page 10: ... Low fluid level in power unit reservoir Secure load by other means Depressurise power unit and hose remove application then fill and bleed the system Application responds to pressurised fluid but system does not maintain pressure Leaky connection Clean reseal with thread sealant and tighten connection Leaking cylinder seals Replace worn seals Look for excessive contamination or wear Replace conta...

Page 11: ...ac com Page 11 of 12 Item Description 1 Handle 2 Electric motor 3 Carbon brush 4 Tank cover 5 Relief valve 6 Power cable 7 Operation cord 8 Oil plug 9 Delivery port 3 8 NPTF 10 Pendant switch 2 4m 8 0 Parts Breakdown List 8 1 High Level Description of Parts ...