Stay clear of loads supported by hydraulics. A cylinder, when used as a load lifting 
device, should never be used as a load holding device. After the load has been raised 
or lowered, it must always be supported mechanically 

 

WARNING: 

 

 

The system operating pressure must not exceed the pressure rating of the lowest 
rated component in the system. Install pressure gauges in the system to monitor 
operating pressure. It is your window to what is happening in the system 

 

 

Always wear appropriate personal protective equipment

 

(PPE) when operating 

hydraulic equipment. The operator must take precaution against injury due to failure 
of the tool or work piece(s) 

 

 

Do NOT

 hold or stand directly in line with any hydraulic connections while pressurising 

 

 

Do NOT

 attempt to disconnect hydraulic connections under pressure. Release all line 

pressure before disconnecting hoses

 

 

 

All personnel must be clear before lowering load or depressurising the system

 

 

 

Do NOT

 attempt to lift a load weighing more than the capacity of the cylinder 

 

IMPORTANT: 

 

 

If at any stage, the safety related decals become hard to read, these must be replaced 

 

 

Minimum age of the operator must be 18 years. The operator must have read and 
understood all instructions, safety issues, cautions and warnings before starting to 
operate the equipment. The operator is responsible for this activity towards other 
persons 

 

 

Do NOT

 lift hydraulic equipment by the hoses or couplers. Use the carrying handle or 

other means of safe transport

 

 

 

Hydraulic equipment must only be serviced by a qualified hydraulic technician. For 
repair service, contact the Durapac authorised service centre in your area. To protect 
your warranty, use only high-quality hydraulic oil

 

 

CAUTION: 

 

 

KEEP HYDRAULIC EQUIPMENT AWAY FROM FLAMES AND HEAT.

 Hydraulic fluid can 

ignite and burn. Excessive heat will soften packings and seals, resulting in fluid leaks. 
Heat also weakens hose materials and packings. For optimum performance do not 
expose equipment to temperatures of 65°C (150°F) or higher. Protect all equipment 
from weld spatter 

 

 

No alteration should be made to this device 

3.1

 

Hydraulic Power Units 

 

Do

 use a gauge or other load measuring instrument to verify load 

 

Do NOT

 exceed the rated capacity of the power unit or any equipment in the system. 

Burst hazard exists if connection pressure exceeds rated pressure 

 

Do NOT

 operate the system with bent or damaged couplers or damaged threads 

Summary of Contents for DPA-16

Page 1: ...NT PTY LTD 2 186 Granite Street GEEBUNG QLD 4034 Australia sales absoluteequipment com au Phone 61 7 3865 4006 Maximum Operating Pressure 700 bar Instruction Manual Reciprocating Air Hydraulic Power U...

Page 2: ...n inspection be done by qualified personnel and that any missing or damaged parts decals warning safety labels or signs are replaced with Durapac authorised replacement parts only Any power unit that...

Page 3: ...decals become hard to read these must be replaced Minimum age of the operator must be 18 years The operator must have read and understood all instructions safety issues cautions and warnings before s...

Page 4: ...h your hands The force of escaping hydraulic fluid can inflict injury Do NOT subject the hose to potential hazard such as fire sharp objects extreme heat or cold or heavy impact Do NOT allow the hose...

Page 5: ...ing Air from the System in the Maintenance Section 5 0 Operation IMPORTANT Always monitor pressure load or position using suitable equipment Pressure may be monitored by means of an optional manifold...

Page 6: ...t may require service and maintenance 6 1 Adding Hydraulic Fluid WARNING Always add oil with cylinders fully retracted or extended if pull cylinders or the system will contain more oil than the reserv...

Page 7: ...nd air dryer is installed and SAE grade oil 5W to 30W is used 6 5 Storage 6 5 1 When not in use depressurise and disconnect the hydraulic power unit from the application 6 5 2 Wipe clean thoroughly an...

Page 8: ...g application connection Replace application connection Application responds slower than normal Loose connection or coupler Tighten connection or coupler Restricted hydraulic line or fitting Clean and...

Page 9: ...Hyd Power Unit V1 0 www durapac com Page 9 of 10 8 0 Parts Breakdown Note Not all components of the power unit are replacement items but are illustrated as a convenient reference of location and posi...

Page 10: ...em ZCZ1018 1 63 Air inlet spring ZCZ1063 1 19 HP nozzle o ring ZCZ1019 2 64 Pin ZCZ1064 1 20 Oil drain valve ZCZ1020 1 65 Foot pedal ZCZ1065 1 21 Oil drain valve spool ZCZ1021 1 66 Return spring ZCZ10...

Reviews: