background image

-4-

Due to high temperatures, this appliance should be installed and used only in an approved 

fireplace or firebox away from flammable objects (curtains, clothing, rugs, furniture, etc.).  

Flammable objects should not come into contact with the appliance or the flames.  Keep them 

at least three feet away.  Never place any objects on the appliance or inside the burner.

The appliance becomes very hot when in operation.  Keep children and adults (and pets) away 

from flames and hot surfaces to avoid burns or clothing ignition.  The appliance will remain hot 

for a time after shutdown.  Allow the appliance to cool for at least 30 minutes before touching 

it.  Carefully follow instructions for refueling while appliance is in use.

Never leave children unattended and carefully supervise young children when they are in the 

room where this appliance is in use.

When installed in a fireplace, you must operate this appliance with a fireplace screen in place.  

Make sure the fireplace screen is closed while running the appliance.

Keep the appliance area clear and free from combustible materials, gasoline, and other 

flammable vapors and liquids.

This appliance is for decorative purposes only and should not be used as a heater.
Do not store the duraflame illuma-fuel

®

 canisters near the appliance.  Store illuma-fuel tightly closed in 

its original canister in a dry, cool place, out of direct sunlight and away from heat sources, flammable 

objects and open fires, and out of the reach of children.  If swallowed, seek medical attention immediately.  

In case of contact with eyes, flush immediately with cool water for 15 minutes and seek medical 

attention.  For contact with skin, rinse well with cool water.  If irritation develops, see your doctor.
Do not remove a duraflame illuma-fuel canister from the appliance until the canister is completely empty.
WHAT TO DO IN THE EVENT OF A FUEL SPILL OR FUEL LEAK: DO NOT light the burner.  

Extinguish any open flame near the spill.  Wipe up the spill, and wait at least 5 minutes for the 

residue to evaporate.  In addition to the potential for fire, spilled duraflame illuma-fuel can damage 

some surfaces like wood and leather.  Wipe up any spills immediately.
Install this appliance in compliance with the laws of your local jurisdiction.  This appliance shall 

not be installed in a bedroom or bathroom, unless installed as a vented appliance inside a vented 

fireplace.  Do not install this appliance in trailers, boats or vehicles.
If a gas line has been run to your fireplace, all gas connections must be disconnected by a 

qualified service technician prior to installing this appliance.
The appliance must be set on a level surface in your fireplace firebox or table.
This appliance has not been tested for use with fireplace glass doors.  To reduce the risk of fire 

or injury, do not install or use glass doors with this appliance when installed in a fireplace.  If the 

fireplace has glass doors, never operate the appliance with the glass doors closed. Heat buildup 

within the fireplace could cause the glass doors to break or burst, or cause the release of harmful 

combustion products into the living area.
If the fireplace has vents at the bottom, the vents must be opened before running the appliance.  
This appliance is designed to be smokeless.  If the unit emits smoke, extinguish the appliance (by 

turning the knob on the side – see Section VIII. OPERATION), wait for the appliance to cool down 

for at least 30 minutes, and check for any debris that may be causing the smoke.  Note: During 

initial operation, slight smoking might occur due to the burning off of manufacturing residues.  This 

is a normal condition.
Do not use cleaning materials or agents such as furniture polish, wax, carpet cleaner, or similar 

products in the room where the appliance is located while the appliance is in use.  If heated, 

Summary of Contents for illuma 64000

Page 1: ...tallation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual for correct installation and operational procedures WARNING This appliance is designed for installation only in a solid fuel burning masonry fireplace a UL127 factory built fireplace or in an ANSI Z21 91 ventless firebox or on a table or cabinet There are no other standards for this type...

Page 2: ...up 5 III Minimum Firebox Dimensions 7 IV Clearances 7 V Installing Damper Stop 7 VI Installation 7 VII Installing the Fuel Canister 10 VIII Operation 10 IX Refueling 12 X Adjustments 13 XI Maintenance 13 XII Troubleshooting 15 XIII Parts List 16 Warranty 17 ...

Page 3: ...is placed away from curtains clothing or any other combustible material c When placed inside a fireplace make sure it is installed per instructions in this manual Never move this appliance while it is in operation or when there is still a flame in the burner no matter how small the flame is Moving the appliance while burning may cause spilling of fuel inside or outside the appliance which could re...

Page 4: ...ster is completely empty WHAT TO DO IN THE EVENT OF A FUEL SPILL OR FUEL LEAK DO NOT light the burner Extinguish any open flame near the spill Wipe up the spill and wait at least 5 minutes for the residue to evaporate In addition to the potential for fire spilled duraflame illuma fuel can damage some surfaces like wood and leather Wipe up any spills immediately Install this appliance in compliance...

Page 5: ...afely away from the device while igniting and while the appliance is in use Do not leave the appliance burning unattended Extinguish the flames before you leave the house go to bed or leave the room for an extended period of time Never leave children unattended near the appliance while it is in use Extinguish the flames by rotating the knob on the side this will close the burner cover and extingui...

Page 6: ...ng codes In the absence of local codes use the latest edition of The National Fuel Gas Code ANSZ223 1 also known as NFPA54 available from American National Standards Institute National Fire Protection Association Inc 25 West 43rd Street 4th floor OR 1 Batterymarch Park New York NY 10036 Quincy Massachusetts USA 02169 7471 This appliance is designed to burn with very low emissions so that it requir...

Page 7: ...ireplace and burner function as a system If the fireplace is spilling combustion gases into the room check draft with a match candle or smoke stick reposition the damper clamp to open the damper wider until a positive draft i e all combustion emissions go up the chimney is obtained VI INSTALLATION 1 Carefully remove the contents of the carton You should find The burner base Figure 1 Four 4 tempere...

Page 8: ... option you can place loose decorative glass or small rocks in the areas between the front glass or back glass or both and the burner Make sure the top level of the loose material is not higher could be lower than the top of the burner The material has to be larger than 3 16 in size and smaller than 1 in size for each piece These materials could be purchased from your supplier or at the store you ...

Page 9: ... 9 Figure 4 Placement of right glass panel Figure 3 Placement of rear glass panel Figure 6 Placement of front glass panel Figure 5 Placement of left glass panel ...

Page 10: ...he fuel is about to run out You can refuel the appliance at this time see Section IX or let the flame die down VIII OPERATION WARNING If you do not follow these instructions exactly a fire may result causing property damage personal injury or loss of life NOTE During initial operation of the new appliance and at the beginning of each burn season the appliance may emit a slight odor This is normal ...

Page 11: ...may not ignite using the sparker because the fuel is evaporating at a higher rate than usual and creates and oxygen free environment around the sparker If that happens either wait for a while for the fuel to cool down or ignite the fuel in the burner using a long match or a butane igniter In case you use a match or igniter when the fuel is hot be carefull not to have your face near the burner beca...

Page 12: ... acts as a flame shield Please note that even though the area indicated in Figure 11 is cool areas of the door closer to the flame may be hot 2 Check the fuel canister and make sure IT IS EMPTY 3 Grasp the empty canister by the notches provided in the canister body see Figure 11 Pull it up and tip it so that it clears the bracket make sure the back side of the canister is tipped so it is lower tha...

Page 13: ...eed more frequent cleaning due to excessive lint from carpeting bedding material pet hair etc The only maintenance needed for the continued good performance of this appliance is periodic cleaning at least once per year or more depending on frequency of use and checking for leaks Note that after some time heat might cause the stainless steel burner to discolor slightly This is natural To clean the ...

Page 14: ...alled properly see Figure 12 The top surface of the piercer should be level If it is higher on the back end or on one side then turn it around and place it back in place again 6 Check for leaks by installing a fuel canister into the appliance and letting it sit for five minutes Check for leaks in the areas shown in Figure 10 before igniting the fuel Figure 12 How to install piercer ...

Page 15: ...ng the burner to the fuel reservoir might be clogged Starting at the tube opening in the bottom of the burner run a thin flexible wire through the length of the tube to remove the obstruction The battery in the igniter may be dead Replace it with a new battery The sparker tip may be out of position The tip of the sparker should be about above the level of the sparking point Carefully bend the wire...

Page 16: ... 16 XIII PARTS LIST Part Numbers 64001 Small Glass 64002 Large Glass 61002 Igniter 61007 Canister Tray Piercer 61010 Masonry Screws 61011 Sparker 64003 Hold Downs ...

Page 17: ...duct and or Duraflame Inc which will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Correction in the manner provided above shall constitute a fulfillment of all liabilities of Duraflame Inc with respect to the quality of the product The product MUST be installed by a person capable of following all instructions in accordance with a...

Page 18: ... the above limitation on implied warranties or exclusion or limitation on damages may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state For information about this warranty write to Attn Consumer Affairs Duraflame Inc 2894 Monte Diablo Ave Stockton CA 95203 www duraflame com ...

Reviews: