-12-
Figure 10
Check for leaks on the floor of the fireplace under the areas indicated.
IX. REFUELING
This appliance is designed so that one canister of illuma-fuel
®
(1 Liter) will provide a continuous
supply of fuel to the burner for about two hours and thirty minutes*. To allow for uninterrupted
burning beyond this time, the burner has been designed so that a few minutes before the fuel is
completely exhausted, the flame will start to shift to the right side of the burner. At this point, you can
replace the empty canister with a full one. This can be done while the appliance is burning—there is
no need to extinguish the flames.
To change the canisters :
1. Open the door on the left side of the appliance. The open door acts as a flame shield. Please note that
even though the area indicated in Figure 11 is cool, areas of the door closer to the flame may be hot.
2. Check the fuel canister and make sure IT IS EMPTY.
3. Grasp the empty canister by the notches provided in the canister body (see Figure 11). Pull it
up and tip it so that it clears the bracket (make sure the back side of the canister is tipped so it
is lower than the frontside) and then lift it straight up to remove it. Keep the canister away from
the flames. Keep canister tilted down on the left side while removing it. This will ensure that
any small amount of fuel that may still be in the canister does not spill out. DO NOT ALLOW
THE CANISTER TO GET CLOSE TO THE FLAMES.
4. Install a new, foil-sealed canister as described above (see INSTALLING THE FUEL CANISTER,
Steps 2 and 3).
5. After the canister has been installed, close the door. The appliance is now ready for continued use.