6
Electrical Block Diagram – Internal
The following table / diagram defines the internal electrical wiring of the DURACELL POWER CENTER 5 kW, including the base and two
additional expansion battery cabinets. The diagram is for illustrative purposes, and does not reflect the actual physical orientation of the
battery modules within the cabinets.
Note:
DC power cables marked by an asterisk (*) in the table above indicate required modifications to the cable set used in the base battery
cabinet. Only one set of “home run” DC power cables is used per complete system. For example: adding one expansion battery cabinet
requires the replacement of [A3] / [B3] with [A5] / [B5] “home run” cables, and the addition of [A4] / [B4] “daisy chain” jumper cables.
Note: Battery module ground cables are one per battery, with a “home run” to the cabinet chassis ground terminal.
Ref
P/N
Description
Ref
P/N
Description
A1
#3790
DC- module jumper BLK 180 mm
B1
#3789
DC+ module jumper RED 180 mm
A2
#3793
DC- module jumper BLK 400 mm
B2
#3796
DC+ breaker cable RED 400 mm
A3
#3798
DC- terminal jumper BLK 400 mm
A3*
#3798
DC- terminal jumper BLK 400 mm
B3*
#3797
DC+ breaker cable RED 780 mm
A4*
#3801
DC- jumper cable BLK 1100 mm
B4*
#3800
DC+ jumper cable RED 1100 mm
A5*
#3802
DC- terminal cable BLK 1200 mm
B5*
#3799
DC+ breaker cable RED 1200 mm
A6*
TBD
B6*
TBD
C1
#3792
BMS jumper short 210 mm
D1
#3810
PCS-BMS “Y” CAN/Console 3000C
C2
#3794
BMS jumper long 700 mm
P-
#2925
PCS DC- power cable
C3
#3795
BMS jumper cable 1500 mm
P+
#2923
PCS DC+ power cable
Figure 29: DURACELL POWER CENTER 5kW electrical block diagram of internal system components.