background image

 

 

 

 

 

 

 

A.2 Wall bracket installation 

 

The expansion cabinet is included with a wall bracket 

extension that is secured to the base system’s bracket. 

 

1.

 

Align the expansion bracket to the base bracket and 

secure with the mounting hardware provided. 

 

2.

 

IMPORTANT! Secure the bracket to the wall 

using a minimum of four 5/16” lag bolts in 

atleast two wall studs. 

A.3 Mounting the cabinet to the wall  

 

1.

 

Remove the cabinet coupling end plate from the lower right side of the base battery cabinet and install it on the lower right port hole of 

the expansion cabinet. 

2.

 

Follow the cabinet installation instructions in section 4 to secure the cabinet to the wall. 

A.4 Battery module assembly 

 

1.

 

 Follow the assembly instructions in section 5.2 through 5.4. 

2.

 

See section 5.5 (figure 12) – remove the lower DC- cable (referenced A3) from the DC- terminal, and replace with the cable 

referenced A5 in figure 25 below. 

A.5 Battery module wiring 

 

1.

 

Connect the internal power and communication jumper 

cables  as shown in sections 5.5.1 and 5.5.2.  Note the 

relative position of batteries 5 thru 8 as they mirror 

batteries 1 thru 4. 

2.

 

Route the DC power cables, referenced A4 and B4, 

through the coupling port and terminate  them at battery 

#8. 

3.

 

Remove the DC+ breaker assembly. 

4.

 

Remove the DC+ cable referenced B3 (section 5.6, figure 

12) and replace with the cable referenced B5 (shown 

right).  Torque to 15 in-lbs. 

5.

 

Mount the DC+ breaker assembly.  

6.

 

Route the BMS jumper cable referenced C3 through the 

cabinet coupling port and terminate at the link port 

terminals at battery #4 and #5. 

 

 

 

Ref  P/N 

Description 

Pylon p/n 

A4 

#3801 

DC- jumper cable BLK 

1100 mm 

WI0CUS300008 

A5 

#3802 

DC- terminal cable 

BLK 1200 mm 

WI0CUS300006 

B4 

#3800 

DC+ jumper cable 

RED 1100 mm 

WI0CUS300007 

B5 

#3799 

DC+ breaker cable 

RED 1200 mm 

WI0CUS300005 

C3 

#3795 

BMS jumper cable 

1500 mm 

WI0SRJ45815M 

base 

expansion 

Figure 28: Expansion cabinet battery power and communication wiring. 

Figure 27: Expansion wall bracket installation.

 