SPECIFICATIONS
MODEL
PPS1000-1050-120-01
BATTERY
Chemistry Li-Ion
Maximum Capacity
1050Wh ([email protected])
Lifecycles
500 Cycles to 80% capacity
Storage Requirement
Recharge every 3-6 months
Protection Systems*
Over & Under Temperature Protection,
Short Circuit Protection, Overload Protection,
Battery Over Charge and Over Discharge
Protection, DC Input Reverse
Polarity Protection.
PORTS
2x USB-A Port (Output)
5V @ 2.4A per port
2x USB-A Fast Charge Port (Output)
5V@3A, 9V@ 2A, [email protected] 18W Max per port
USB-C Port (Input/Output)
100W Maximum
USB-C Port (Output)
27W
3x 120V AC Port (Output, Pure Sine Wave)
120V, 60Hz (1000W continuous, 2000W Peak)
13V Cigarette Lighter Port (Output)
13V up to 10A
2x DC Port (Output)
13V up to 5A per port
DC Charging Port (Input)
12-30V @6.5A (195W Maximum) DC F6530
connector
Solar Charger Anderson Port
12-30V @ 6.5A (195Wp Maximum)
CHARGE TIME
Wall Charger (120W Charger)
10-11Hrs
Solar Panels
12-13Hrs
Car Charger
21-24Hrs(12V) 10-12Hrs(24V)
Type C 100W PD charging
12-13Hrs
Wall Charger (120W Charger) + Type C 100W
5-6Hrs
GENERAL
Dimensions
13.38*9.29*8.11in (34*23.6*20.6cm)
Weight
24.6lbs (11.15Kg)
Operating Temperature
32-104˚F (0-40˚C)
Storage Temperature
42-85˚F (6-29˚C)
Certifications FCC/DOE/CEC/ETL/RoHS
Warranty
24 Months
The Unit will have the following protection alarms:
Beeps 2 times: Overload protection, shuts down the port.
Beeps 5 times: Over temperature protection, shuts down AC port.
Beeps 7 times: Battery UVP (Once at 5% SOC and again at 0% SOC).
Beeps 8 times: Short circuit protection, shuts down the port.
Beeps 9 times: No load shutdown, Unit shutdown normally.
Beeps 10 times: Abnormal communication between the master controller of the Unit and Inverter, AC icon will
blink and the AC port will shut down.
Beeps 11 Times: Battery related faults. Unit shuts down any charge and discharge.
*
Summary of Contents for POWER 1000
Page 1: ...POWER 1000 USER MANUAL...