Dupla pH-Control Pro User Instructions Download Page 11

11

When the pH Set Point Programming is finished, 

 is flashing .

If you want to activate the CO

2

-night off function and don´t wish to supply CO

2

 during the night, press 

 . Conti-

nue making your settings with item 5 .2 .2 of this instructions .

If you want to keep the manufacturers presetting of the CO

2

-night off function and wish to supply CO

2

 during the 

night, skip the menu item 5 .2 .2 . To do that press – during 

 is flashing - the 

 key until   flashes, acknow-

ledge with 

 Taste and continue with programming the pH Alarm with item 5 .2 .3 of this instructions .

5.2.2 CO

2

-night function

After you have acknowledged flashing 

 with 

 is flashing and 

pH

 is displayed in first line, 

 

is displayed in the third line . Now use the 

 and 

 buttons to change 

 into 

 and acknowledge with 

 .

Please note:

 In case flashing 

 is acknowledged with 

, you directly access pH Alarm programming, 

indicated by flashing  .

When 

 is flashing, press 

 to confirm .

 in the third line is displayed and the hour digits   (or your last programmed value) will flash .

Use the 

 and 

 buttons to set the start hours for not supplying CO

2

 in the night between 0 and 23 .

Press the 

 button, the minutes digits   will flash .

Use the 

 and 

 buttons to set minutes between 0 and 59 and acknowledge with 

 .

Attention:

 

Here 

 is the time when the stop of CO

2

 supply should beginn, for example at 21.00 when your 

lighting is switched off

.

 in the third line is displayed and the hour digits   (or your last programmed value) will flash .

Use the 

 and 

 buttons to set the off time hours for CO

2

 supply stop in the night .

Press the 

 button, the minutes digits   will flash .

Use the 

 and 

 buttons to set minutes between 0 and 59 and acknowledge with 

 .

Attention:

 Here 

 is the time when the stop of CO

2

 supply should end, for example at 9.00 when your 

lighting is switched on.

Please note:

 When the night off beginning time is reached the display shows a measured but not regulated 

pH value in the first line. In the third line for the set value a 

 is displayed.

When the night off function programming is finished,   is flashing and you can go on with pH Alarm programming .

Summary of Contents for pH-Control Pro

Page 1: ...a com Dohse Aquaristik GmbH Co KG Dohse Aquaristik GmbH Co KG www dohse aquaristik com Item no 80286 Status 03 2013 Version 1 1 Using instruction pH Control Pro Using instruction pH Control Using inst...

Page 2: ...imer programming 7 3 3 1 Setting the timer control mode 7 3 3 2 Programming turn on and turn off times 7 3 3 3 Programming interval control 7 3 4 Manual activation deactivation 7 3 5 Display light 7 4...

Page 3: ...ol unit and connection strip Connection strip LED Slot 1 for pH value programming Slot 2 for programming the timer function Connecting cable Fastening rail Set of screws for fastening rail Cable tie C...

Page 4: ...is designed exclusively for use in enclosed rooms All electronic components of the device must only be operated whilst they are free from defects Should the mains supply be damaged please please retu...

Page 5: ...is fitted with LEDs In operating mode this indicates the active control of the external device 2 2 Safety shutdown during programming When entering into the programming mode both slots are deactivated...

Page 6: ...surement and therefore the control circuit the Dupla pH Control Pro provides an optional six week calibration memory function Caution If no pH electrode is connected to the Dupla pH Control Pro so tha...

Page 7: ...between external device at slot 2 is permanently activated automatic modus and interval mode 3 3 2 Programme turn on and turn off times If Automatic Mode is selected up to 8 turn on turn off times can...

Page 8: ...ttons you can scroll through the menu items Short pressing of acknowledges the selection which sub menu item to access As well in the sub menu structure you can scroll through the menu items with the...

Page 9: ...0 and 23 Press the button the minutes digits flash Use the or button to set the minutes between 0 and 59 Press the button the seconds digits flash Use the or button to set the seconds between 0 and 5...

Page 10: ...button again until flashes and confirm by pressing the button Proceed making your settings with item 5 2 4 of the instructions If you want to calibrate your pH Electrode press the button to select CA...

Page 11: ...isplayed and the hour digits or your last programmed value will flash Use the and buttons to set the start hours for not supplying CO2 in the night between 0 and 23 Press the button the minutes digits...

Page 12: ...s finished flashes 5 2 4 Deactivation activation of the audible pH alarm pH pH pH When flashes press to de activate the audible alarm When flashes acknowledge with to deactivate the pH alarm Alternati...

Page 13: ...ge with To calibrate the pH Electrode for saltwater aquaria use the or button until flashes dip the electrode into the pH 9 solution for saltwater and acknowledge with 7 A measured running value is di...

Page 14: ...ible pH alarm is deactivated the audible calibration reminder alarm is deactivated as well The optical alarm is not affected from that 5 3 Timer programming 5 3 1 Setting the timer control mode pH pH...

Page 15: ...urn off time flash Use the or button to set the hours between 0 and 23 Press the turn off time minute digits will flash Use the or button to set the minutes between 0 and 59 Press the turn off time se...

Page 16: ...l OFF time use the or button to set the hours between 0 and 96 Please note 24 means every day 48 every two days 72 every three days 96 every four days Press the minutes will flash Use the or button to...

Page 17: ...the programme mode for slot 2 is reactivated The display shows your set values again If slot 2 is time controlled and not temperature controlled or on the second line together with on the third line i...

Page 18: ...ion memory function On Night function CO2 supply during the night On not permanent on but regulated corresponding to day programmation Timer mode means automatic 8 Sources of faults In the case of a p...

Page 19: ...the difference between the on and off switching point 0 1 pH alarm window 0 1 4 0 pH calibration memory Six week BNC Adaptor cable length 20 cm Timer mode automatic switching Max 8 On Off Timer mode...

Page 20: ...Dohse Aquaristik GmbH Co KG Otto Hahn Str 9 D 53501 Gelsdorf Telefon 49 0 22 25 94 15 0 E Mail info dohse aquaristik de Internet www dupla com HOBBY Aquaristik Hobby Terraristik Dupla DuplaMarin...

Reviews: