APT3100 Smart Pressure Transmitter
Operation Manual M3100-E01B
43 DUON System Co., Ltd.
Appendix I
LCS DISPLAY CODE of APT3100
No. CODE
Contents
1
e-rd
. Read Analog EEPROM for MCU EEPROM
2
-00-
. Finish to read Analog EEPROM for MCU EEPROM
3
r-22
. LCD stat Message (Transmitter Version “r-22”)
4
S-FL
. Sensor Fail
5
s-op
. Sensor Input Over Pressure
6
e-tt
. Write MCU EEPROM for Analog EEPROM
7
end
. Finish to write MCU EEPROM for Analog EEPROM
8
2ero
. Initial message in using Zero button
9
Span
. Initial message in using Span button
10
2-tr
. Initial message of Sensor Zero Trim in using button
11
-tr-
. Good job of Sensor Zero Trim in using button
12
2ter
. Over 10% of Sensor Zero Trim limit in using button
13
-2e-
. Finish Zero configurations in using Zero button
14
-sp-
. Finish Span configurations in using Span button
15
Sete
. Fail EEPROM-write in using button
16
Sper
. Min/Max span Over in using Zreo/Span Button
17
Beri
. Wrong button in using button
18
a-cl
. Clear all MCU EEPROM
19
Cp-0
. Verify Data Message
20
-cp-
. EEPROM SETTING UP TERMINATION MESSAGE
21
e-fa
. MCU data set error
22
----
. Clear MCU EEPROM in User area
23