background image

t: 

01905 797989

e: 

[email protected]

 | w: 

www.duomo.co.uk

1

GS300M 

3 Channel Gas Detection Controller

FEATURES

 

Three channel protection

 

230VAC supply

 

Wall or panel mounted

 

Positive safety option

 

Detection of Toxic 0-300ppm / Explosive Gas(es) 

0-20%LEL 

 

4-20mA signal sensor input

 

3 alarm stages - 1

st

 & 2

nd

 pre-alarm and main alarm

 

IP44 protective rating

 

CE certified and approved to EN 61010-1, EN 50270, 

 

EN 50271, EN 45544-3, EN 60079-29-1

 

2 year guarantee - 3 year by registering at duomo.co.uk

OVERVIEW

The GS300M is a 230V three channel and sensor wall or panel 

mounted gas detection controller. It can be connected to toxic and 

explosive sensors. An LED display indicates sensor status and 

faults. 

If the remote sensor senses the presence of gas, it sends a 

proportional  4-20mA  signal  back  to  the  GS300M.  When  the  first 

alarm level is reached the pre-alarm relay is activated (See Alarm 

Settings). If the level continues to rise the main alarm relay will be 

energised.

For explosive or toxic gases, the electrical supply to the safety shut 

off  valve  is  broken  when  the  main  alarm  threshold  is  reached. A 

general alarm is sounded. 

Should the controller enter fault condition the safety shut off valve 

closes to fail safe. A self-diagnostic feature looks for return sensor 

voltage and ensures correct functionality.

The GS300M controller is compatible with all the Duomo 

conventional sensors.

SPECIFICATION

Power

Power Supply

230VAC 50Hz ± 10%

Secondary Battery

12VDC ± 10% Max 2.2Ah

Battery Charger

Charger Capacity 2.2Ah

Power Consumption

11W Maximum @ 13.8V

Relay Contact Range

10A resistive

Alarm Settings

Pre-Alarm No.1

8% LEL / 120ppm

Pre-Alarm No.2

13% LEL / 200ppm

Main Alarm

Fixed at 20% LEL / 300ppm

Sensor Fault

Short circuit, interruption, sensor deterioration

Technical Specification

Dimensions

Width 144mm 

|

 Height 144mm 

|

 Depth 110mm

Display

N/A

Mounting

Wall or panel mounted

Input Signal

4-20mA

Device Precision

1% FS

Reaction Time

<10 seconds

Working Temperature

-10°C to 40°C

Start-up Self-Diagnostic Delay

90 seconds

Protective Rating

IP44

Configuration

Positive Safety

Yes (ON/OFF)

Main Alarm Relay Actuation

Yes (Latching/Temporary Alarm)

Gas Type Selection

Yes (Toxic/Explosive)

Timed Sensor Test Facility

No

Emergency Stop Connections

No

O

2

 Compatibility as Standard

No

Perhipheral Specification

No. of Remote Sensors 

1-3 

Maximum Sensor Distance

100m

Cable Diameter for Sensors

1mm

2

 CSA 

(Screened and earthed at the controller end)

Compatibility

Sensor Compatibility

All Duomo Sensors

Approvals, Certifications and Guarantee

Approvals

EN 61010-1, EN 50270, EN 50271, EN 45544-3, 

EN 60079-29-1

Guarantee

2 year as standard 

3 year by registering at www.duomo.co.uk

3

Channel 

Conventional

4-20mA

IP44

Positive

Safety

Summary of Contents for GS300M

Page 1: ...ure looks for return sensor voltage and ensures correct functionality The GS300M controller is compatible with all the Duomo conventional sensors SPECIFICATION Power Power Supply 230VAC 50Hz 10 Secondary Battery 12VDC 10 Max 2 2Ah Battery Charger Charger Capacity 2 2Ah Power Consumption 11W Maximum 13 8V Relay Contact Range 10A resistive Alarm Settings Pre Alarm No 1 8 LEL 120ppm Pre Alarm No 2 13...

Page 2: ...rough a BMS The relay driving techonogy de energized when triggered will ensure a prompt indication even in case of mains power failure The GS300M has two plug in terminal blocks One is for the incoming mains supply and alarm circuit wiring and the second is for connecting the sensor wiring This reduces the chance of incorrect site wiring The front panel has two overload lights which indicate when...

Page 3: ...r fault condition 9 TEST When pressed checks the sequence and function of GS300M Press and hold to initiate a full function test release once controller is in alarm state required Will eventually activate all relays and their associated outputs 10 1st PRE ALARM Illuminates at 8 LEL Explosive or 120ppm Toxic gas concentration LED illuminates and the Pre Alarm relay 1 is actuated 11 2nd PRE ALARM Il...

Page 4: ... the 1st 3 double DIP switches Toxic or explosive levels These are labelled as GAS or CO on PCB The symbols on the front fascia of the detector are EN standard symbols and refer to any explosive or toxic gas If toxic gas e g carbon monoxide is to be sensed on a given zone move the switch to the CO position If explosive e g natural gas LPG hydrogen etc move the switch to the GAS position Example sh...

Page 5: ...ring should be performed by a qualified person in accordance with current regulations The plug in terminal rail makes installation easy and quick Do not mount close to any heat source or in an area where moisture is likely to effect operation The IP rating of this unit is IP44 Sensors should be positioned as shown below If you require any guidance on this please call Duomo technical support on 44 ...

Page 6: ...nge 0 300ppm Working Temperature 10 C to 60 C Autosetting Yes Protective Rating IP55 Approvals EN50270 EN45544 1 3 Compliant Technical Specification Gas es Detected Carbon Monoxide Dimensions Width 100mm Height 100mm Depth 60mm Display N A Sensor Technology Electrochemical Settings Preset to TWA and STEL Standards Output Signal 4 20mA Sensor range 0 300ppm Working Temperature 15 C to 40 C Autosett...

Page 7: ...iance Technical Specification Gas es Detected Oxygen Dimensions Width 100mm Height 100mm Depth 60mm Sensor Technology Optical Fluorescence based Settings 19 5 or 18 5 of O2 depletion 22 5 23 5 excess Output Signal 4 20mA Sensor range 0 25 Working Temperature 30 C to 60 C Autosetting Yes Protective Rating IP64 Approvals EN50104 and EN50270 Compliant Technical Specification Gas es Detected Methane o...

Page 8: ... ALARM outputs listed in step a are all deactivated Relay LED and Terminal connections Pre Alarm no 2 relay actuated 2nd ALARM LED illuminates and Terminal 8 and 9 will be connected c At 20 LEL 300ppm reading The Main Alarm relay is actuated MAIN ALARM LED illuminates and Terminal 10 and 11 will be connected and terminals 10 and 12 will be broken and the audible alarm will continue to sound With P...

Page 9: ...in the open position The function of the alarm relays both the Pre Alarm and the Main Alarm can be checked by pressing the TEST button on the detector fascia Check that the main alarm action is configured for a latching alarm Switch 2 on 5th DIP switch See Configuring the GS300M There is no supply to the solenoid valve The Main Alarm relay is a volt free contact therfore you must connect the live ...

Page 10: ...cessful A Duomo Commissioning Certificate is provided A certificate from the original maufacturer ensures that the commisioning or servicing carried out is at a high professional standard by a competent and qualified service engineer It is prudent to make electrical connection to the detector terminal plus when withdrawn and leave the plug off the detector so that the Duomo Engineer is the first t...

Page 11: ...t 01905 797989 e sales duomo co uk w www duomo co uk 11 Notes ...

Page 12: ...cestershire WR9 9AH GAS SAFETY CONTROLS DuomoUK linkedin com company duomo uk GS300M 20072021 rev4 This document is protected by copyright No changes by others are permitted without prior authorisation by Duomo UK Ltd Duomo UK Ltd reserve the right to modify and revise this datasheet without notification ...

Reviews: