![Dungs MPA 5111 Manual Download Page 64](http://html1.mh-extra.com/html/dungs/mpa-5111/mpa-5111_manual_2539651064.webp)
63 … 68
62 … 68
Printed in German
y • Edition 02.14 • Nr
. 254 722
15 Time diagram
MPA51xx
by m
ea
ns o
f a
n e
xt
en
de
d m
od
ul
e
Ge
ne
ra
l v
ers
io
n
Vi
es
sm
an
n v
er
si
on
Er
ro
r
W
ai
tin
g f
or h
ea
t r
eq
ue
st
W
ai
tin
g f
or p
ar
am
et
er r
ec
or
d s
tic
k a
dj
us
tm
en
t
Id
le s
ta
te c
on
tr
ol
: F
an
/s
te
pp
ed m
ot
or
Id
le s
ta
te c
on
tr
ol L
DW (
ai
r p
re
ss
ur
e s
w
itc
h)
W
at
ch
do
g l
oa
di
ng p
ha
se
St
ar
tu
p p
ha
se
: F
an
/s
te
pp
ed m
ot
or
W
ai
tin
g f
or a
ir p
re
ss
ur
e
VP
S A
: D
ec
is
io
n
VP
S A : E
m
pt
yi
ng t
he a
re
a b
et
w
ee
n t
he v
al
ve
s
VP
S A
: T
es
t t
im
e V
1
VP
S A
: F
ill
in
g t
he a
re
a b
et
w
ee
n t
he v
al
ve
s
VP
A A
: G
as p
re
ss
ur
e d
et
ec
tio
n
VP
S A
: T
es
t t
im
e V
2
Pr
e-
ae
ra
tion
A
Parameter
P40
P42
P43
P44
P45
P60
Time
0.
..
0.
..
m
ax
. 3
m
in
m
ax
. 2
m
in
m
ax
. 2
m
in
3 s
m
ax
. 2
m
in
m
ax
. 3
0 s
0.1
s
1.
..3
s
1.
..2
40
s
1.
..3
s
0.1
s
1.
..2
40
s
0.
..1
h
State number
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Safety chain
Watchdog
Alarm
Temperature controller
Additional valve *4
Y1
Y3
V1
Y2
Y1
V2
Y3
Y2
Ignition
Fan relay
PWM1 (fan)
*2a
*2b
PWM2 (for ex. analogue 0...10 V)
●
*2a
*2b
PWM3 (for ex. analogue 4... 20 mA)
●
*2a
*2b
Stepped motor
●
*2a
*2b
Flame (ionisation)
LDW *1
GDW min.
GDW VPS *5
Parameter record stick active
●
Parameter VPS Startup
Parameter VPS Regular switch-off
Pr
e-
ae
ra
tion
B
Ig
ni
tion
p
os
iti
on
G
as
d
et
ec
tio
n
G
DW
VP
S
Pr
e-
ig
ni
tion
SZ
A i
gn
iti
on
SZ
A - F
la
m
e d
et
ec
tio
n
St
ab
ili
sa
tio
n fl
am
e A
St
ab
ili
sa
tio
n fl
am
e B
C
ha
ng
eo
ve
r t
o t
he s
ta
nd
ar
d m
od
e
St
an
da
rd m
od
e
C
ha
ng
eo
ve
r a
fte
r r
eg
ul
ar s
w
itc
h-
off
VP
S B
: D
ec
is
io
n
VP
S B : E
m
pt
yi
ng t
he a
re
a b
et
w
ee
n t
he v
al
ve
s
VP
S B
: T
es
t t
im
e V
1
VP
S B
: F
ill
in
g t
he a
re
a b
et
w
ee
n t
he v
al
ve
s
VP
A B
: G
as p
re
ss
ur
e d
et
ec
tio
n
VP
S B
: T
es
t t
im
e V
2
Fo
llo
w
-up
ti
m
e
Pos
t-a
er
at
ion
Re
st
ar
t pro
te
ct
io
n
W
ai
tin
g f
or h
ea
t r
eq
ue
st
La
ck o
f g
as G
DW
M
IN
W
ai
tin
g
pro
gr
am
P61
P62
P63
P64
P65
P66
P70
P80
P41
P42
P43
P44
P45
P82
P83
P84
*3
0.
..1
h
m
ax
. 2
m
in
0.
..1
h
0.
..1 m
in
.
0.
5.
..9
, 4 s
0.
5 s
1.
..2
00
s
1.
..2
00
s
m
ax
. 2
m
in
.
0.
..
1.
..3
0 s
0.1
s
1.
..3
s
1.
..2
40
s
1.
..3
s
0.1
s
1.
..2
40
s
1.
..6
0 s
0.
..1
h
0.
..1
h
0.
..
0.
..
x m
in
.
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
1
35
36
*2c
*2d
*2e
*2f
*2g
*2h
*2i
*2j
*2a
*2c
*2d
*2e
*2f
*2g
*2h
*2i
*2j
*2a
*2c
*2d
*2e
*2f
*2g
*2h
*2i
*2j
*2a
*2c
*2d
*2e
*2f
*2g
*2h
*2i
*2j
*2a
goes to the fault switch-off. The waiting pro-
gram state is triggered by a lack of gas or an
open safety chain.
*4) The start help valve can be switched on
and off at any time (parameter). However it
must be activated with the beginning of the
state "Waiting for gas pressure" at the earli-
est and during the valve test after a regular
switch-off at the latest.
*5) The GDW VPS is monitored during the
valve test. Additionally, the parameter P46
can define whether the minimum pressure
monitoring via GDWVPS during operation
between state 17 and state 25 is active or not.
*6) The flame is detected here and must be
generated in this state at the latest.
*6