www.factorybuysdirect.com
200376-01A
18
INSTALLATION
PRESSURE TESTING HEATER GAS CONNECTIONS
1. Open equipment shutoff valve (see Figure
15, page 17).
2. Open main gas valve located on or near
gas meter for natural gas or open pro-
pane/LP supply tank valve.
3. Make sure control knob of heater is in the
OFF position.
4. Check all joints from equipment shutoff
valve to control valve (see Figure 16 or
17, page 17). Apply a noncorrosive leak
detection fluid to all joints. Bubbles form-
ing show a leak.
5. Correct all leaks at once.
6. Light heater (see
Lighting Instructions
on
page 21). Check all other internal joints
for leaks.
7. Turn off heater (see
To Turn Off Gas Ap-
pliance
, page 22).
INSTALLING LOGS
See Log Assembly Instructions included with your log set for proper log installation.
BATTERY INSTRUCTIONS
CAUTION: Do not dispose of
batteries in fire, batteries may
explode or leak.
• Battery is included.
• Remove battery when depleted.
• Be sure to observe proper polarity (+/-)
when installing or replacing the battey.
Damage due to improper battery installation
may void the warranty on the product.
• For long periods of non-operation, remove
batteries from all components for safety.
Figure 19 - Installing Battery in Ignitor
AAA
Battery
Positive
UP
Ember Material
Burner
Figure 18 - Placing Ember Material
(heater may vary from image shown)
PLACING EMBER MATERIAL
Separate the ember material into light pieces
smaller than the size of a dime. Place the
pieces around the round gas ports starting in
the front of the burner and working your way
toward the back of the burner. Do not place
ember material on the burner ports or the
carry over ports leading to the left and right
rear burner slots.
WARNING: Use only ember
material provided with log set.
Do not add additional ember
material.
Place ember material on front
burner port only. DO NOT PLACE
EMBER MATERIAL ON PORTING
BEYOND THE GRATE, OVER THE
MIDDLE OR BACK BURNERS.