www.factorybuysdirect.com
200376-01A
10
Figure 4 - Minimum Clearance for
Combustible to Wall
INSTALLATION
IMPORTANT:
Vent-free heaters add moisture
to the air. Although this is beneficial, installing
heater in rooms without enough ventilation air
may cause mildew to form too much moisture.
See
Air for Combustion and Ventilation
, pages
7 and 8.
Before beginning assembly or operation of the
product, make sure all parts are present. If any
part is missing or damaged, do not attempt to
assemble, install or operate the product. Con-
tact customer service for replacement parts.
Before installing heater, make sure you have
the items listed below:
• Hardware package (provided with heater)
• Electric drill with 3/16" drill bit
• Phillips screwdriver
CHECK GAS TYPE
Be sure your gas supply is right for your heat-
er. Otherwise, call dealer where you bought
the heater for proper type heater.
CLEARANCES TO
COMBUSTIBLES
WARNING: Maintain the
minimum clearances. If possible,
provide greater clearances from
floor, ceiling, and adjoining wall.
Measure from outermost point
of heater.
Minimum Fireplace Clearance To
Combustible Materials
Side Wall 16", Ceiling 42", Front 36"
LOG SIZING REQUIREMENTS
Minimum Firebox Size
Height 20", Depth 14",
Front Width 30", Rear Width 23"
Minimum Clearances For Side
Combustible Material, Side Wall
and Ceiling
A. Clearance from the side of the fireplace
cabinet to any combustible material and
wall should follow diagram in Figure 4.
B. Clearance from the top of the fireplace
opening to the ceiling must not be less
than 42".
Minimum Noncombustible Material
Clearances
If Not Using Mantel
Note: If using a mantel, proceed to If Using
Mantel. If not using a mantel, follow the infor-
mation below.
You must have noncombustible material(s)
above the fireplace opening. Noncombustible
materials (such as slate, marble, tile, etc.)
must be at least 1/2" thick. With sheet metal,
you must have noncombustible material be-
hind it. Noncombustible material must extend
at least 12" up (for all models). See Figure 5
for minimum clearances.
*Minimum 16" from Side Wall
*
Figure 5 - Heat Resistant Material (Slate,
Marble, Tile, etc.) Above Fireplace
Noncombustible
Material Distance
Requirements for Safe Installation
(A) 12" or more:
Noncombustible
material OK.
(A) Between 8" and 12":
Install fireplace hood accessory.
(A) Less than 8":
Noncombustible
material must be extended to at least 8".
See
Between 8" and 12"
, above. If you
cannot extend material, you must operate
heater with flue damper open.