83
Communication settings
Communication command table (continue)
Hitachi Command
Function
Operation
Header Data (7 bytes)
Command Data (6 bytes)
Description
Header
Code
Packet Data Size
CRC
Action
Type
Setting
Code
Setup
Gateway
1st octect
Get
BE EF
03
06 00
93 05
02 00
19 29
00 00
Gateway
2nd octect
Get
BE EF
03
06 00
D7 05
02 00
1A 29
00 00
Gateway
3rd octect
Get
BE EF
03
06 00
2B 04
02 00
1B 29
00 00
Gateway
4th octect
Get
BE EF
03
06 00
5F 05
02 00
1C 29
00 00
DNS
1st octect
Get
BE EF
03
06 00
F3 08
02 00
21 29
00 00
DNS
2nd octect
Get
BE EF
03
06 00
B7 08
02 00
22 29
00 00
DNS
3rd octect
Get
BE EF
03
06 00
4B 09
02 00
23 29
00 00
DNS
4th octect
Get
BE EF
03
06 00
3F 08
02 00
24 29
00 00
MAC 1st
Byte
Get
BE EF
03
06 00
0F 17
02 00
40 29
00 00
MAC 2nd
Byte
Get
BE EF
03
06 00
F3 16
02 00
41 29
00 00
MAC 3rd
Byte
Get
BE EF
03
06 00
B7 16
02 00
42 29
00 00
MAC 4th
Byte
Get
BE EF
03
06 00
4B 17
02 00
43 29
00 00
MAC 5th
Byte
Get
BE EF
03
06 00
3F 16
02 00
44 29
00 00
MAC 6th
Byte
Get
BE EF
03
06 00
C3 17
02 00
45 29
00 00
Memu
Position
Set
Top left
BE EF
03
06 00
57 D5
01 00
1D 30
00 00
Top right
BE EF
03
06 00
C7 D4
01 00
1D 30
01 00
Bottom left
BE EF
03
06 00
37 D4
01 00
1D 30
02 00
Bottom right
BE EF
03
06 00
A7 D5
01 00
1D 30
03 00
center
BE EF
03
06 00
97 D7
01 00
1D 30
04 00
Get
BE EF
03
06 00
64 D5
02 00
1D 30
00 00
OSD Time
Out
Set
Always On
BE EF
03
06 00
16 58
01 00
8E 22
00 00
10 Seconds
BE EF
03
06 00
B6 5E
01 00
8E 22
0A 00
30 Seconds
BE EF
03
06 00
B6 51
01 00
8E 22
1E 00
60 Seconds
BE EF
03
06 00
16 49
01 00
8E 22
3C 00
Get
BE EF
03
06 00
25 58
02 00
8E 22
00 00
Message
Box
Set
Off
BE EF
03
06 00
EA 59
01 00
8F 22
00 00
On
BE EF
03
06 00
7A 58
01 00
8F 22
01 00
Get
BE EF
03
06 00
D9 59
02 00
8F 22
00 00
Infrared
Remote
Set
Off
BE EF
03
06 00
17 96
01 00
16 24
02 00
On
BE EF
03
06 00
E7 96
01 00
16 24
01 00
Get
BE EF
03
06 00
44 97
02 00
16 24
00 00
Summary of Contents for 9080WUSS