Precautions 

 

SPRAY CANS MUST BE INSTALLED AS LAST, JUST BEFORE THE COVER CLOSING AND AFTER REALIZING ALL 
THE REQUIRED CONNECTIONS, PROVIDED POWER AND ELECTRICAL SIGNALS FROM CONTROL PANEL AND 
DETECTORS. 
IF NOT PEPEROSSO SHOULD ACCIDENTALLY ACTIVATE THE NEBULISATION. 

 

USING THE DEVICE ACCORDING TO THESE INSTRUCTIONS IS LEGAL. 
IT IS SUGGESTED TO SIGNALIZE ITS PRESENCE WITH SPECIAL SIGNS EASILY VISIBLE TO ALERT THE RISK OF 
IRRITATING SPRAY 

 

ALL THE INSTALLING OPERATIONS MUST BE DONE WITHOUT THE SPRAY CANS INSIDE THE DEVICE! 

 

TO ALLOW THE GAS  IS RELEASED  CORRECTLY  INTO THE ENVIRONMENT AND AVOID  SPOTS,  AVOID THE 
PRESENCE OF ITEMS THAT MEETS THE NOZZLES OF CANS WITHIN 2 METRES. 

 

PEPEROSSO  IS  ACTIVATED  AT  CONTROL  PANEL  ARMING  (COMMAND  CONNECTED  TO  INPUT  IN1):  USE 
ONLY TOTAL ARMING COMMAND. 
DO NOT ACTIVATE PEPEROSSO WHEN IN PARTIAL ARMING BECAUSE IS NOT GUARANTEED THE COMPLETE 
ABSENCE OF PEOPLE IN PROTECTED AREA 

 

DO  NOT  INSTALL  THE  DEVICE  WHEN  IN  PRESENCE  OF  NOT  PACKAGED  FOOD  OR  ENVIRONMENT 
INCOMPATIBLE WITH GAS NEBULISATION. 

 

ATTENTION: PEPEROSSO IS PROTECTED AGAINST WIRE CUTTING: IF PROPER SIGNALS ARE MISSING ON 
MONITORING  INPUTS  (EXAMPLE:  WIRE  CUT,  BLACKOUT  OR  CONTROL  PANEL  BATTERY  TEST  OR  ITS 
FAILURE), GAS NEBULISATION CAN STARTS. 

 

After nebulisation 

The gas nebulized is not harmful to health although it is very irritating. 
The active principle decay after about 36 hours. 
After the area has been saturated with the gas, it is necessary to proceed with an accurate decontamination 
as the residual chilli pepper fine dust may react again after depositing on surfaces. 
Furniture and home furnishings are not damaged. 

 

ensure proper ventilation 

 

irritation subsides in about 30 minutes 

 

contamination of clothes can prolong the action 

 

be careful to not touch your eyes and wash your hands thoroughly 

 

to avoid unpleasant irritation is recommended the use of masks during cleaning 

 

 

Summary of Contents for PEPEROSSO

Page 1: ...Installation and use manual Made in Italy PEPEROSSO Dissuader with nebulization irritating gas 14 09 M1 2 1 H1 0 F 1 0 ENG ...

Page 2: ...NS OF THIS MANUAL AND THE LAW REGARDING ELECTRICAL SYSTEMS Legal notes THE ACTIVE PRINCIPLE USED BY PEPEROSSO IS A NATURAL ESSENCE OF CHILLI PEPPER CALLED OLEORESIN CAPSICUM OC WITH A CONCENTRATION OF 10 THE IMPORTANCE OF THE NATURAL ESSENCE IS THAT IT IS LEGAL AND SAFE FEW ILLEGAL PRODUCTS EXIST IN FACT WITH ACTIVE PRINCIPLES OF CHEMICAL DERIVATION THAT IN ITALY ARE CONSIDERED CHEMICAL AGGRESSIVE...

Page 3: ...tion 5 Precautions 6 After nebulisation 6 Installation 7 Installation 9 Connections 11 Technical 13 TERMINALS 14 JUMPERS 15 BUTTONS 15 LEDS 15 Tamper 15 Battery substitution 16 Substitution of spray cans 17 After a nebulisation 17 Substitution for maintenance 17 Test 18 Stand alone mode 19 ...

Page 4: ...ning sensation persuading the intruder to leave immediately the area Gas is emitted by three disposable sprays of 20 ml located inside Peperosso Peperosso can be connected by wire to an alarm control panel Gas diffusion occurs only after the activation of the three different wired inputs control panel activated alarm start and additional sensor confirmation close to nebulizer avoiding any gas nebu...

Page 5: ...E OF ALARM NEBULISATION IS READY When the system is in alarm the control panel signals it to Peperosso input IN2 that prepares nebulisation the gas is not yet emitted depends on input IN3 state AN INTRUDER CAUSE NEBULISATION TO START Peperosso verify if the confirm input input IN3 signals a detection it s the confirm an intruder is near and thus gas nebulisation can start It s possible to connect ...

Page 6: ...BECAUSE IS NOT GUARANTEED THE COMPLETE ABSENCE OF PEOPLE IN PROTECTED AREA DO NOT INSTALL THE DEVICE WHEN IN PRESENCE OF NOT PACKAGED FOOD OR ENVIRONMENT INCOMPATIBLE WITH GAS NEBULISATION ATTENTION PEPEROSSO IS PROTECTED AGAINST WIRE CUTTING IF PROPER SIGNALS ARE MISSING ON MONITORING INPUTS EXAMPLE WIRE CUT BLACKOUT OR CONTROL PANEL BATTERY TEST OR ITS FAILURE GAS NEBULISATION CAN STARTS After n...

Page 7: ... windows Motor base Screw for motor base Anti opening tamper Screw for motor base CN1 connector removable Space for spray cans Anti removing tamper Battery compartment Electronic board Anti opening tamper Wall mounting hole Wall mounting hole Wall mounting hole Cable path Screw for motor base Fig 1 Fig 2 Fig 3 Fig 4 ...

Page 8: ...8 Fig 6 Fig 5 ...

Page 9: ...luded set the battery and lock it with the appropriate metal plate 4 Plug the end line CN7 and motor CN2 connectors 5 Connect the battery ATTENTION By connecting the battery the motor move forward the plunger leave it go completely forward 6 Screw the three screws of the motor base 7 Cable the CN1 connector according to the functioning mode will be used instantaneous or driven by IN3 see schemes a...

Page 10: ...ing the test spray can containing water see Test paragraph At the end of test block Peperosso using IN1 provide a positive 12 V 13 Peperosso must stay at rest with the plunger completely back and settled Only in this position is possible to fix the spray cans with the straps fig 6 In this phase to avoid unwanted nebulisations caused by error on wiring or moved on CN1 remove the CN2 motor connector...

Page 11: ...11 Connections Driven mode confirm from IN3 input ...

Page 12: ...12 Instantaneous mode immediate nebulisation in case of alarm Control panel connection with remote activation surveillance ...

Page 13: ... control interface Confirmation is monitored up to 8 minutes after the end of NEBULISATION READY signal Outputs 1 output for power supply 12 V 500 mA 2 A for 100 ms MAX 1 output for failure of Peperosso 1 output for nebulisation occurred Functioning Gas nebulisation can occur only when system is armed IN1 unlocked and after activation of IN2 input alarm and confirm of IN3 input local detector remo...

Page 14: ...tches to GND in case of failure on motor power supply circuit If the main supply voltage or the battery voltage are lower than 10 5 V the OUT D output switches to GND signalling the failure inadequate voltage The voltage check is made when IN1 BLOCK is at GND that is with Peperosso unlocked If OUT D is at GND it is necessary to check the power voltages are correct between 12 and 13 8 V if power vo...

Page 15: ...Tamper deactivate JP2 Anti removal Tamper active Anti removal Tamper deactivate BUTTONS K1 Plunger return button after nebulisation Allow to after nebulisation occurred rearm the device LEDS OFF ON LED Normal functioning Battery poles inverted Tamper In case of cover removing the tamper line through T1 T2 terminals is opened ...

Page 16: ...and end line connectors 10 Plug in the battery connector the motor moves the plunger forward 11 Screw the three screws the motor base 12 Plug in the CN1 connector already cabled 13 Enable Peperosso removing the positive 12 V from IN1 from control panel 14 Press K1 button to bring the plunger to rest 15 At this point make a functioning test using the test spray can containing water see Test paragra...

Page 17: ...eperosso removing the positive 12 V from IN1 3 Press the K1 button to bring the plunger to rest 4 Block Peperosso giving the positive 12 V to IN1 5 Unplug the CN2 connector which power the motor in this way the plunger is mechanically blocked 6 Substitute the spray cans 7 Plug in the CN2 motor connector 8 Close the cover Substitution for maintenance 1 Deactivate the control panel IN1 and IN2 to 12...

Page 18: ...perosso is connected in Instantaneous mode the nebulisation of spray with water starts immediately o if is connected in Driven mode provoke the confirm detector connected to IN3 Peperosso will nebulize the spray can with water Verify the detection area of the confirm detector is properly covered and adjusted to avoid false detections at the end of test change the test spray can with the chili pepp...

Page 19: ...in stand alone mode no control panel required Note it s necessary to connect the detector as in scheme on page 11 Peperosso Must be powered with 12 V Detector Connect to Peperosso on IN3 as confirm Hardware key Close IN1 and IN2 towards 12 V disabling Peperosso ...

Reviews: