background image

8

 

Manual settings

 

To enter the manual settings (virtual dip-switches) 
proceed as follows: 
1.

 

With  the  control  panel  disarmed,  press  the 
PRT  button  (12)  for  3  seconds  to  enter  the 
settings 

2.

 

The control panel emits 3 beeps and positions 
itself  on  the  first  function  indicated  by  the 
flashing LED (1) 

3.

 

The LED ring (6) indicates the setting of the 
selected function with a different color 

GREEN = function enabled 
RED = function disabled 

4.

 

To  change  the  function  setting,  briefly  press 
the central button (5) 

5.

 

To advance to the next function, briefly  press 
the PRT button (12) and the next LED will flash 

 

Function 

Description 

Function 1 
 
Led 1 
 
Web access 
without 
password 

Enabled (GREEN LED) 

access with APP requires only 
the username, without 
password. 
INSTALLER access is always 
enabled. 

Disabled (RED LED) 

access with APP requires both 
username and password. 
INSTALLER access is enabled 
and disabled by an 
Administrator user.

 

Function 2 
 
Led 2 
 
Wi-Fi Access 
Point Mode 

Enabled (GREEN LED) 

The Wi-Fi is set in Access Point 
mode, i.e. it is possible to 
connect with a PC, tablet or 
phone directly to the Wi-Fi 
integrated in the control panel. 
The control panel automatically 
assigns an IP to the device that 
connects in DHCP. 
 
Wi-Fi name = EzyLan_<serial> 
Password = 12345678 
Security = WPA2 / WPA1 / PSK 
 

Disabled (RED LED) 

The Wi-Fi is set to connect to a 
Wi-Fi router. The parameters 
for the connection must be set 
by software.

 

 
6.

 

To  exit  the  settings  and  save  the  changes, 
press and hold the PRT button (12) until a long 
beep is heard. 

7.

 

To  exit  the  settings  without  saving  the 
changes, do not press any button for 10 sec, 
the  control  panel  will  automatically  exit  the 
settings with a long beep. 

 

9

 

Programming of the control panel

 

The  control  panel  can  be  programmed  using  the 
dedicated application "DUEVI Connect", available 
for Windows, IOS and Android systems. 
Once  the  software  has  been  installed  on  the 
device, the graphical interfaces must be updated 
on first run. 

 

If  there  is  a  local  network,  you  can  connect  the 
control panel with a network cable and connect to 
the  same  network  with  the  device  on  which  the 
DUEVI Connect app is installed. 

 

If there is no local network or it is not possible to 
connect  a  network  cable,  simply  connect  the 
device  on  which  the  DUEVI  Connect  app  is 
installed  directly  to  the  WIFi  of  the  control  panel 
(which is by factory in Access Point mode). 

 

Access Point factory settings: 
 
Name= EzyLan_<serial> 
Password= 12345678 

 

Once  you  have  made  one  of  the  previous 
connections,  you  can  add  the  control  unit  to  the 
list  of  devices  to  be  managed,  by  entering 
SETTINGS -> MANAGE DEVICES: 

 

SEARCH FOR LOCAL DEVICES - 
automatically searches for control panels 
present on the local network. In some cases, 
the modem / router or the device itself may 
block this type of request, so it will be 
necessary to proceed with the manual 
addition. 

 

ADD WITH SERIAL / QR CODE - enter the 
serial number by hand / scan the QR code of 
the label 

 
Press  the  "Back"  button  to  return  to  the  Home 
Page of the App, where you will find your control 
panel with the factory name "Mainboard". 
Click  on  the  name  of  the  control  panel  to  reach 
the login page (LOGIN). 

10

 

Homepage (INFO)

 

Access the control panel as USER INSTALLER  

 

User name = installer 
Password = admin (by default is disabled) 

 

As  soon  as  you  log  in,  the  main  screen 
(homepage) will open, which displays a series of 
information about the control panel: 

 

System

 

– Summary of the main programmed 

elements 

 

Connections

 

– Indication of the status of the 

various  connections.  By  pressing  the  icon 

 

(info), more details are displayed 

Summary of Contents for EZY-LAN HW 3B

Page 1: ...i removal tamper function is available starting from the HW 4B version 13 holes for wall plugs 14 control panel supports 15 hole for magnet optional To mount proceed as follows 1 Use the bracket as a...

Page 2: ...EST mode 4 Power supply and battery The control panel is powered by an external 12Vdc 2Ampere power supply to be connected to the appropriate jack input 11 Power must be supplied from a Limited Power...

Page 3: ...g beep 9 Programming of the control panel The control panel can be programmed using the dedicated application DUEVI Connect available for Windows IOS and Android systems Once the software has been ins...

Page 4: ...e zone Daylight savings time System Settings Login with password Reset to factory default Reboot of the panel 11 2 Connections PRIORITY OF CONNECTIONS Ethernet is the primary channel that is used if a...

Page 5: ...E NOTE The keyfob is not considered a device but must be added within the individual user 12 1 1Wireless devices It is possible to add new wireless devices in several ways wireless transmission of the...

Page 6: ...presence control Associated sectors indicates for which sectors the siren will be active Visual and sound signals for Alarm L1 Panic alarm Arming Disarming System status 12 1 2IP Devices Shelly It is...

Page 7: ...door management etc The SECTORS page contains the list of all created sectors two sectors are already present by default Perimetrali and Volumetrici Pressing the icon info expands the display of the z...

Page 8: ...with extended privileges can enable installer can modify notifications etc Normal user with reduced privileges Police user limited to the telephone number to call in case of alarm Associated sectors i...

Page 9: ...g every day only some days of the week once a month The PROGRAMS page contains the list of all time programs created Pressing the icon trash can deletes the program Pressing the icon gear you enter t...

Page 10: ...s properties Logic name is the name with which the logic is identified in all menus notifications events etc Triggering event represents the event that triggers the execution of the defined operations...

Page 11: ...ol panel switches to test mode and the RGB LEDs of the control unit flash blue The homepage continues to display panel information 13 1 TEST Menu The test menu accessible by pressing the icon double r...

Page 12: ...urning off 2 With the control panel off long press the PWR button 8 the led ring starts flashing white and violet 3 Continue to hold down the PWR button 8 and at the same time press briefly the centra...

Reviews: