1.8
Lateral setting of straight stitches on throat plate needle hole edges,
arresting of zigzag stitch setting mechanism
Regulation
If the sewing equipment allows using the maximum zigzag stitch width,
which is characteristic of the particular machine type, the position of
the border straight stitches should be adjusted so that it aligns with the
zigzag stitch border. If the throat plate needle hole is narrower than the
maximum zigzag stitch width of the particular sewing machine type, the
lever for the position setting of the border stitch must be fixed in the
central position.
–
Loosen the screw (1) and turn the lever (2) in the position, in which
the needle will perform no lateral motion when turning the lever (3).
–
Locate the stop (4) to the lever (2) and fix it with the screw (1).
–
Loosen the screw (5) and turn the lever (2) to the position, in which
the needle performs no side motion when moving the lever (3).
–
Locate the stop (6) to the lever (2) and fix it with the screw (5).
–
Adjust the arresting lever (7) in this position.Tighten the arresting
nut (8-invisible), loosen the screw (9), turn the lever (7) to 1 mm
space from the casing (10) and tighten the screw (9).
–
If the sewing equipment does not allow using the maximum zigzag
stitch width, screw the regulating screw (11) into the lever (2) and
fix it in the central position.
11
GB
2
4
1
3
2
11
5
6
8
9
3
7
10