22
7 Installation Details
7.1 Wrench torque sheet for
installation
Outside diameter
Torque
Additional tightening
torque
Ф6.35mm
1/4in
1500N.cm(153kgf.cm)
1600N.cm(163kgf.cm)
Ф9.52mm
3/8in
2500N.cm(255kgf.cm)
2600N.cm(265kgf.cm)
Ф12.7mm
1/2in
3500N.cm(357kgf.cm)
3600N.cm(367kgf.cm)
Ф15.9mm
5/8in
4500N.cm(459kgf.cm)
4700N.cm(479kgf.cm)
Ф19mm
3/4in
6500N.cm(663kgf.cm)
6700N.cm(683kgf.cm)
7.2 Connecting the cables
The power cord should be selected according
to the following specifications sheet.
Appliance Amps
AWG Wire Size
15
14
20
12
30
10
The cable size and the current of the fuse or
switch are determined by the maximum
current indicated on the nameplate which
located on the side panel of the unit. Please
refer to the nameplate before selecting the
cable, fuse and switch.
7.3 Pipe length and the elevation
Models
Pipe size
Gas
Liquid
DA1215-H1
3/8in
(Ф9.52mm)
1/4in
(Ф6.35mm)
DA1815-H2
1/2in
(Ф12.7mm)
1/4in
(Ф6.35mm)
DA2415-H2
5/8in
(Ф15.9mm)
3/8in
(Ф9.52mm)
Models
Standard
length
Max.
Elevatio
n
Max.
Length
A
Additional
refrigerant
DA1215-H1-O
DA1215-H1-I
7.5m
(24.6ft)
10m
(32.8ft)
25m
(82.0ft)
15g/m
(0.53oz/3.3ft)
DA1815-H2-O
DA1815-H2-I
7.5m
(24.6ft)
20m
(65.6ft)
30m
(98.4ft)
15g/m
(0.53oz/3.3ft)
DA2415-H2-O
DA2415-H2-I
7.5m
(24.6ft)
25m
(82.0ft)
50m
(164ft)
30g/m
(1.07oz/3.3ft)
Summary of Contents for DA1215-H1
Page 7: ...5 2 2 Part names of Indoor Outdoor units ...
Page 13: ...11 ...
Page 16: ...14 6 Wiring Diagram 6 1 Indoor Unit 12000 BTU 115 VOLT 18000 BTU 220 VOLT 24000 BTU 220 VOLT ...
Page 17: ...15 ...
Page 18: ...16 6 2 Outdoor Unit DA1215 H1 O ...
Page 19: ...17 DA1815 H2 O ...
Page 20: ...18 DA2415 H2 O ...
Page 21: ...19 For DA1215 H1 O ...
Page 22: ...20 For DA1815 H2 O For DA2415 H2 O ...
Page 23: ...21 ...
Page 54: ...52 P U P V ...
Page 55: ...53 P W P N ...