PRODUCT FICHE

 - Ref Delegated regulation (EU) n° 1253/2014

(English)

1

0

1

1

Manual control

Clock control

Central demand control

Local demand control

(no DCV)

(no DCV)

(+ 1 sensor)

(+ min 2 sensors)

cold

-30,5

-

-40,7

-54,1

average

-14,1

-

-19,8

-27,0

warm

-4,8

-

-7,7

-11,5

cold

B

-

A

A+

average

E

-

E

B

warm

F

-

F

E

Unidirectional

-

Unidirectional

Unidirectional

Variable speed

-

Variable speed

Variable speed

None

-

None

None

Not applicable

-

Not applicable

Not applicable

400

-

400

400

72,42

-

72,42

72,42

45

-

45

45

0,08

-

0,08

0,08

50

-

50

50

0,10

-

0,10

0,10

1

-

0,85

0,65

Manual control

-

Central demand control

Local demand control

Not applicable

-

Not applicable

Not applicable

2,23%

-

2,23%

2,23%

Not applicable

-

Not applicable

Not applicable

Not applicable

-

Not applicable

Not applicable

Not applicable

-

Not applicable

Not applicable

Not applicable

-

Not applicable

Not applicable

120,2

-

86,8

50,8

cold

3355

-

4290

5536

average

1715

-

2193

2830

warm

776

-

992

1280

Specific energy consumption 

(SEC) in (kWh/(m².an))

SEC class

Trade mark

Duco

Model reference

0000-4215 / 0000-4225 / 0000-4229 / 0000-4232 / 0000-4233 / 0000-4237 / 0000-4238 / 0000-4304 / 0000-4305 / 

0000-4438 / 0000-4490 / 0000-4501 / 0000-4607

DucoBox Silent

Indoor/outdoor air tightness in (m³/h)

Annual electricity consumption (AEC) in (kWh 

electricity/a)

Annual heating saved (AHS) 

in (kWh primary energy/a)

DucoBox Silent

Declared maximum external leakage

rates in (%)

Mixing rate in (%)

Position and description of visual filter 

warning

Instructions to install regulated 

supply/exhaust grilles

Pre-/dis-assembly instructions

Airflow sensitivity to pressure variations at + 

20 Pa / -20Pa

Sound power level Lwa at reference flow rate 

in dB(A))

Reference flow rate in (m³/s)

Reference pressure difference in (Pa)

SPI en (W/m³/h)

Declared maximum internal leakage

rates in (%)

Typology

Type of motor

Type of heat recovery

Thermal efficiency of heat recovery in (%)

Maximum flow rate in (m³/h)

Electric fanpower input at maximum flow rate 

in (W)

Control factor and control typology

Instructions according to legislative regulations area of application

www.duco.eu

 Ecodesign Delegated regulation (EU) n° 1253/2014 (Duco V20200701)

4

ENGLISH 

L2000651 Installation guide for DucoBox Silent (Revision N | 13.07.2020)

02

Product sheet

Summary of Contents for DucoBox Silent 0000-4215

Page 1: ...Installation guide ENGLISH DucoBox Silent Product version 17xxxx and above Step by step instructions duco tv L2000651 Revision N 13 07 2020...

Page 2: ...ng type of home 10 06 E Pairing components 11 06 F Removing replacing components 11 06 H Tips 12 07 Air calibration 12 07 A Air calibration procedure for DucoBox Silent 12 07 B Checking 14 08 Maintena...

Page 3: ...extractor fan that exhausts stale air with excessive CO2 content or humidity On the other it is the system master or brain of the system It receives and interprets signals from slave components measu...

Page 4: ...reference 0000 4215 0000 4225 0000 4229 0000 4232 0000 4233 0000 4237 0000 4238 0000 4304 0000 4305 0000 4438 0000 4490 0000 4501 0000 4607 DucoBox Silent Indoor outdoor air tightness in m h Annual el...

Page 5: ...ergy consumption SEC in kWh m an SEC class Trade mark Duco Model reference 0000 5127 DucoBox Silent 325 Indoor outdoor air tightness in m h Annual electricity consumption AEC in kWh electricity a Annu...

Page 6: ...rgy consumption SEC in kWh m an SEC class Trade mark Duco Model reference 0000 5126 DucoBox Silent 225 Indoor outdoor air tightness in m h Annual electricity consumption AEC in kWh electricity a Annua...

Page 7: ...25 mm upward from 30 m h 100 mm less than 30 m h Or an equivalent based on a specific duct calculation p e for ducts placed in floor screed Make sure that the total counter pressure in the ducts is as...

Page 8: ...e refer to information sheet RF communication L8000018 at www duco eu for further information DUCO RF Power supply 230 VAC Wiring 1 5 mm Frequency 868 Mhz Maximum distance 350 m free field less throug...

Page 9: ...also enables problems in the system to be pinpointed The Duco Network Tool is issued to every installer after attending a free training course at the Duco Academy Please refer to our website or your D...

Page 10: ...ITE or OFF Normal BLUE Component is displayed if changes are being put through via the master ORANGE The system is not working correctly because the DucoBox has not been calibrated Restart the DucoBox...

Page 11: ...replacing is only possible within 30 minutes after the component is paired in or is restarted Restarting can be done by disconnecting the power for a moment After a time span of 30 minutes remove and...

Page 12: ...o eu for information about determining ventilation flow rates 07 A Air calibration procedure for DucoBox Silent The air calibration procedure must be carried out on a calm day no more than wind force...

Page 13: ...rate is obtained This can be done in two ways Using the lower and higher buttons on a paired User controller or CO2 Humidity Sensor Using the DOWN and UP buttons on the DucoBox This requires the cover...

Page 14: ...fter 15 minutes 08 Maintenance service Please refer to the maintenance instructions at www duco eu and view the videos on duco tv for more information For service problems as a user Please contact you...

Page 15: ...15 ENGLISH L2000651 Installation guide for DucoBox Silent Revision N 13 07 2020...

Page 16: ...Installed by L2000651 Document last modified on 13 07 2020 revision N...

Reviews: