23
ENGLISH
12) Operation modes
Introduction
The electronic unit contains a micro-processor to control the gate’s operation modes. These are the four main operation phases :
Phase preceding the gate’s motion
Gate’s fast motion phase
Gate’s slow motion phase
Gate’s pause phase (open gate)
The unit can function in three modes :
Step by step –
This mode is enabled by setting the dip switches 1=OFF 2=OFF
Automatic –
This mode is enabled by setting the dip switches 1=OFF 2=ON
Condominium –
This mode is enabled by setting the dip switches 1=ON 2=
No effect
The
Condominium
mode is the priority operation mode. If more than one modes are selected the priority mode will be enabled.
Notice:
The operation logic setting (dip switch
)
, the work time programming and the pause time programming must be carried out only if the cycle is
concluded or before it starts (with closed gate).
The operating cycle is enabled by a
Opening
Start
or
Closing Start
control.
“
Step-by-step” mode
When the gate is closed, the opening start command determines an opening cycle. At the end of the work time, the gate stops. The operating cycle is
completed (blinker off) and the system waits for a closing start command to determine the closing cycle. If a opening start or closing start command is
supplied when the end of travel has not been reached yet the gate stops.
“Automatic” mode
When the gate is closed, the opening start command determines an opening cycle. At the end of the work time, the gate stops. The pause period
starts (blinker off). At the end of the pause period the gate closes automatically. The operating cycle is complete only when the closing motion has
ended. If a opening start or closing start command is supplied before the end of travel is reached the gate stops. If a opening start or closing start
command is supplied during the pause period the operating cycle is interrupted and the gate does not close automatically.
“Condominium” mode
When the gate is closed, the opening start command determines an opening cycle. At the end of the work time, the gate stops. The pause period
starts (blinker off). At the end of the pause period the gate closes automatically. The operating cycle is complete only when the closing motion has
ended. If a opening start or closing start command is supplied while the gate opens, the command will have no effect. During the closing phase the
opening start command operates whereas the closing start command not operates. If a opening start command is supplied while the gate closes, the
gate will stop and reverse its motion after approx. 2 sec. If a opening start or closing start command is supplied during the pause period, the period will
be reset and the automatic closure will start later.
Important :
If the gate opening is controlled by a clock the “condominium” mode must be enabled.
Note : The opening start and closing start commands can be supplied by the two push-buttons of radio-command.