18
Trouble Shooting Guide
Fault
Cause
Action
The unit can not
start
No fuel
Fill the oil tank with gasoline
The Fuel valve is not turned
on
Turn the fuel valve to ON
The Fuel valve is blocked
Clean the fuel bowl (refer to page 16)
No engine oil or the engine
oil level is low
Add oil
The engine switch is turned
off
Turn the switch to the “on” position
The spark plug fails
Clean or replace the spark plug (refer to
page 17)
There is no power
output
The circuit breaker is in the
off position
Turn the circuit breaker to the “on”
position
The plug is poorly contacted Remove and refit the plug.
The unit shudders
during operation
The choke lever position
is incorrect
Move the choke lever to the “open”
position during operation
The unit emits
white smoke
The temperature of the engine
is too high, maybe overloaded
Let the engine run without load for more
than 10 minutes
The fuel is contaminated
Use fresh clean fuel
The unit emits
black smoke
The air filter is dirty
Clean the filter element of the air filter
The load is too heavy
Reduce load to the rated limit
The unit emits blue
smoke
The engine oil is overfilled
Drain oil to correct level
The engine oil type is
incorrect
Choose appropriate engine oil model (refer
to page 11)
The power
decreases
The spark plug fails
Clean or replace the spark plug (refer to
page 17)
The valve clearance are out
of adjustment
Adjust the valve clearance (refer to page
17)
The environmental condition required to operate the generator:
·Suitable temperature: -15
℃
-40
℃
.
·Suitable humidity: lower than 95%.
·Suitable altitude: under 1,000 meters (The power load should be reduced where the generator is
used at altitudes greater than 1000 meters.)
The generator unit can only be loaded to the rated power under the specified environment
conditions. If the environment conditions are inconsistent with the above standards, or if the
cooling conditions of the engine and generator unit are poor; for example, when operating
in enclosed areas, it is necessary to reduce the power load. It is also necessary to reduce the
power load when the temperature, altitude or relative humidity exceed the standards.
If
t
he generator does not
w
ork properly in optimal conditions, please take to the nearby
dealer or after-sales service center for inspection.