12
Operation
Starting the Engine
1. Unplug all loads from the generator.
2. Turn the Fuel valve to the ON position.
3. Move the choke lever to the CHOKE position.
NOTE: If engine has been operating and
is being restarted leave the choke lever in the
RUN position.
4. Turn the switch on the control panel to ON.
a. The generator unit is electric.
start and can be started by
turning the switch around to
the START position. In order
to extend the service life of
the battery, do not turn the
switch for more than 3
seconds and the interval
between two attempts should
be at least 10 seconds apart.
b. For the manual start generator by pulling the
recoil starting grip until the engine runs. NOTE:
Do not allow the grip to snap back after starting;
return it gently to its original place. Allow the
engine to run for 10-20 seconds, then move the
choke lever to the RUN position.
5. To operate electrical equipment, turn the
circuit breaker ON. Please note that when using
several appliances at the same time, do not add
the next one unless the generator and other
items are running normally. The total power of
the loads should not exceed the rated power of
the unit.
c. For remote start generator,the farthest distance
between remote control and generator is 50m.
Push the "START" button on the remote control
and the generator will start automatic
al
ly.
START
STOP
START
STOP
REMOTE