16- PERIODIC CLEANING
16.1- Lenses and reflectors
Even a fine layer of dust can substantially reduce the luminous output . Regularly clean all lenses
and the reflector using a soft cotton cloth, dampened with a specialist lens cleaning solution.
16.2- Fans and air passages
The fans and air passages must be cleaned approximately every 6 weeks. This periodic cleaning
will depend of course, on the conditions in which the projector is operating. Suitable instruments
for performing this type of maintenance are a brush and a common vacuum cleaner or an air
compressor. If necessary, clean the fans and air passages more frequently.
17- PERIODIC CONTROLS
Lamp
The lamp should be replaced if there is any visible damage or deformation due to heat. This will
help to avoid the danger of the lamp exploding.
Mechanical parts
Periodically check all mechanical parts, gears, guides, belts, etc. for wear and tear, replacing them
if necessary. Periodically check the lubrication of all components, particularly the parts subject to
high temperatures. If necessary, lubricate with suitable lubricant, available from your D.T.S.
distributor. Check the tension of the belts and adjust it if necessary.
Electrical components
Check all electrical components for correct earthing and proper connection of all connectors;
refasten them if necessary.
Fuse replacement
Locate the fuse, which protects the lamp and electronics, in the base of the XR8.
Using a multimeter, test the condition of the fuse, replacing it with one of equivalent type if
necessary.
Attention
Disconnect mains power prior to removing the projector housing.
18