DTS DRIVENET 1664 User Manual Download Page 21

 

 
User Manual 

Ver. 1.00 

19 di 43 

 

 

 

DRIVENET 

 

 

 

COMMAND NUMBER 

DESCRIPTION 

152 

Query Content DTR 

153 

Query Device Type 

160 

Query Actual Level 

161 

Query Max Level 

162 

Query Min Level 

163 

Query Power On Level 

164 

Query System Failure Level 

165 

Query Fade Time / Fade Rate 

176-191 

Query Scene level 

192 

Query Groups [0-7] 

193 

Query Groups [8-15] 

194 

Query Random Address High 

195 

Query Random Address Middle 

196 

Query Random Address Low 

 

SUPPORTED SPECIAL COMMANDS: 

COMMAND NUMBER 

DESCRIPTION 

256 

Terminate 

257 

Store Data to DTR 

258 

Initialize 

259 

Randomize 

260 

Compare 

261 

Withdraw 

264 

Search Address High 

265 

Search Address Middle 

266 

Search Address Low 

267 

Program Short Address 

268 

Verify Short Address 

269 

Query Short Address 

270 

Physical Selection 

 
DALI DEFAULT SETTINGS: 

NAME 

DEFAULT VALUE 

Power On Level 

254 [100%] 

System Failure Level 

254 [100%] 

Min Level 

1 [0.1%] 

Max Level 

254 [100%] 

Fade Rate 

7 [45 Step/s] 

Fade Time 

0 [0s] 

Short Address 

rnd 

Group Low [0-7] 

Group High [8-15] 

Scene [1-16] 

0xFF 

 
DALI FIXED SETTINGS: 

NAME 

VALUE 

Dali Version 

Device Type 

6 (LED) 

Physical Min Level 

1 [0.1%] 

 

DALI controllers identify each DRIVENET 28 EZ as 8 DALI gears and automatically assign 8 addresses of the 
64 available for each controller. 
The first gear is assigned at the first DALI address available while the other addresses are assigned 
consecutively. By using a DALI controller it is possible to change the sequence of addresses. 

Summary of Contents for DRIVENET 1664

Page 1: ......

Page 2: ......

Page 3: ...0 1 di 43 DRIVENET Release 1 0 For more information Language EN Art Net Designed by and Copyright Artistic Licence Holdings Ltd All other trademarks both marked and not marked are the property of thei...

Page 4: ...application of the products or circuits described herein FRA Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute respo...

Page 5: ...EZ 18 10 1 DALI Functions 18 11 Display Functions 20 11 1 LCD Display functions 20 11 2 Display Functions for DRIVENET 28 EZ 25 12 DMX Protocol 27 12 1 DMX Personality 1 27 12 1 1 DMX Personality 1 f...

Page 6: ...User Manual Ver 1 00 4 di 43 DRIVENET 14 1 Fans and Air Passages 41 14 2 Electrical Components 41 15 Troubleshooting 42 NOTES 43...

Page 7: ...row with regular waste 2 General Warning Carefully read the instruction contained in this User Manual as they give important information regarding your safety and others during installation use and ma...

Page 8: ...WER 832 832 24 Vdc 832 POWER 832 POWER 24Vdc 1664 1664 24Vdc Use only AC supplies 100 240 V 50 60 Hz for DRIVENET 28 EZ 416 416 POWER 832 832 24Vdc 832 POWER 24Vdc 1664 24Vdc 180 240 V 50 60 Hz for DR...

Page 9: ...ed area lacking sufficient air flow T 40 C a The ambient temperature should not exceed 40 C and should not be lower than 10 C If the product has been subjected to drastic temperature variances for exa...

Page 10: ...ENET 416 POWER DRIVENET 832 DRIVENET 832 24Vdc DRIVENET 3U RACK DRIVENET 832 POWER DRIVENET 832 POWER 24Vdc DRIVENET 1664 DRIVENET 1664 24Vdc A B C Model mm in mm in mm in DRIVENET 28EZ 87 3 4 111 8 4...

Page 11: ...24Vdc OUTPUT CHANNELS Channel x group 8 4chx2 16 4chx4 32 4chx8 64 4chx16 MAX INPUT 250 W 600 W 1200 W 1200 W 600 W 2400 W 1200 W 2200 W 1100 W INPUT VOLTAGE FREQUENCY RANGE 100 240Vac 50 60 Hz 180 24...

Page 12: ...hat presents any operational defect DRIVENET 28 EZ can be installed on a wall or on a truss thanks to the two mounting brackets included For wall mounting installation brackets can be mounted on short...

Page 13: ...User Manual Ver 1 00 11 di 43 DRIVENET Wall mounting with two brackets on long sides Truss mounting installation...

Page 14: ...User Manual Ver 1 00 12 di 43 DRIVENET 8 Connection Panel DRIVENET 28 EZ DRIVENET 416 and 416 POWER...

Page 15: ...User Manual Ver 1 00 13 di 43 DRIVENET DRIVENET 832 and 832 24Vdc DRIVENET 832 POWER and 832 POWER 24Vd DIVENET 1664 and 1664 24Vdc...

Page 16: ...other Do not connect the cable ground to the XLR chassis The plug housing must be isolated Connect the mixer signal to the DMX IN of the DRIVENET plug and connect it to the next unit by connecting the...

Page 17: ...t add 8 to the former DMX address Device 3 A017 A Device 6 A041 DRIVENET 416 and 416 POWER can be used in eight different DMX modes 16 ch default 32 ch 10 ch 14 ch 40 ch 56 ch 24 ch or 1 ch mode If yo...

Page 18: ...24Vdc 832 POWER 832 POWER 24Vdc 1664 1664 24Vdc in 10 channels mode select the Z1 type 8 bit 10ch mode from the DMX MODE menu under DMX SETUP and set the following addresses on the mixer Device 1 A001...

Page 19: ...IFIC PIDs NO_DMX_ACTION To set the desired fixture s behavior in case DMX signal is missing or not available 1 Black out 2 All channels 60 3 All channels 100 4 CUSTOM RED NO DMX 0 250 Default 0 GREEN...

Page 20: ...eport commands are accepted also if DMX signal is enabled DRIVENET 28 EZ accepts the following DALI commands COMMAND NUMBER DESCRIPTION 0 OFF 1 Up Fade Rate 2 Down Fade Rate 3 Step Up Increment Arc Po...

Page 21: ...rch Address Middle 266 Search Address Low 267 Program Short Address 268 Verify Short Address 269 Query Short Address 270 Physical Selection DALI DEFAULT SETTINGS NAME DEFAULT VALUE Power On Level 254...

Page 22: ...rm any changes UP DOWN To navigate the menus structure To scroll between any value FIRMWARE RELEASE 1 19 DRIVENET 416 1664 1 13 DRIVENET 416 POWER 832 832 24Vdc 1664 24Vdc RDM Device Model ID 0x0D21 2...

Page 23: ...6 224 DMX ch mode same as Z1 type 16 bit 14 ch but each output with independent DMX control Output 1 DMX 1 Output 2 DMX 15 Output 3 DMX 29 Z1 SHORT FULL 8 BIT 6x4 24 CH 6x8 48 CH 6x16 96 CH Z1 short f...

Page 24: ...AX DEFAULT 100 GREEN MAX BLUE MAX AMBER WHITE MAX SMOOTH OFF 20 Allows to select the value of delay in ms for RGBW RGBA and Dimmer channels reaction to DMX or program variation OFF Instant response 4...

Page 25: ...DMX controller DRIVENET is forced to Z1 Type 8 bit 10 ch mode In REC MODE via DMX the unit will need 13 channels to be correctly programmed DMX ch 11 CHPR1 0 24 no function 25 255 it is possible to se...

Page 26: ...ure monitoring MEASURES Status of the connected units Allows to check the status current and voltage of the connected units TIME Shows the total unit life time and the RGBW RGBA life time SOFTWARE DIS...

Page 27: ...lay Functions for DRIVENET 28 EZ The DRIVENET 28 EZ display panel shows all the available control menus By selecting the available functions on these menus you will be able to change the fixture s set...

Page 28: ...s to select CUSTOM mode 8channels with independent DMX address LED SMOOTH OFF 20 Allows to select the value of delay in ms for Dimmer channel reaction to DMX or program variation OFF Instant response...

Page 29: ...ue 2 8 White 2 9 Red 3 10 Green 3 11 Blue 3 12 White 3 13 Red 4 14 Green 4 15 Blue 4 16 White 4 12 1 2 DMX Personality 1 for DRIVENET 832 832 POWER for DRIVENET 832 832 24Vdc 832 POWER 832 POWER 24Vdc...

Page 30: ...44 White 11 45 Red 12 46 Green 12 47 Blue 12 48 White 12 49 Red 13 50 Green 13 51 Blue 13 52 White 13 53 Red 14 54 Green 14 55 Blue 14 56 White 14 57 Red 15 58 Green 15 59 Blue 15 60 White 15 61 Red...

Page 31: ...n 000 255 Proportional color from min to max 11 BLUE 3 DMX value Function 000 255 Proportional color from min to max 12 WHITE 3 DMX value Function 000 255 Proportional color from min to max 13 RED 4 D...

Page 32: ...min to max 25 RED 7 DMX value Function 000 255 Proportional color from min to max 26 GREEN 7 DMX value Function 000 255 Proportional color from min to max 27 BLUE 7 DMX value Function 000 255 Proport...

Page 33: ...to max 40 WHITE 10 DMX value Function 000 255 Proportional color from min to max 41 RED 11 DMX value Function 000 255 Proportional color from min to max 42 GREEN 11 DMX value Function 000 255 Proport...

Page 34: ...in to max 55 BLUE 14 DMX value Function 000 255 Proportional color from min to max 56 WHITE 14 DMX value Function 000 255 Proportional color from min to max 57 RED 15 DMX value Function 000 255 Propor...

Page 35: ...o 120ms 180 204 Random strobe Master and RGBW active 205 229 Random strobe Full 230 255 Open 2 DIMMER DMX value Function 000 255 Proportional dimmer 3 RED DMX value Function 000 255 Proportional color...

Page 36: ...only for DRIVENET 416 0 2000K 128 5500K 255 7200K If channel 7 White NO FUNCTION DMX range value 0 43 000 255 Smooth RGB linear Hue correction 9 MACRO DMX value Function 000 014 No Function 015 029 M...

Page 37: ...strobe 205 229 Random strobe Full 230 234 Channel sequence CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 230 100 ms for channel 231 200 ms for channel 232 300 ms for channel 233 400 ms for channel 234 500 ms for ch...

Page 38: ...6 7 Output Channel 7 8 Output Channel 8 1 OUTPUT CHANNEL 1 DMX value Function 000 255 Proportional dimmer from min to max 2 OUTPUT CHANNEL 2 DMX value Function 000 255 Proportional dimmer from min to...

Page 39: ...255 Proportional dimmer from min to max 12 6 DMX Personality 4 for DRIVENET 28 EZ DMX Personality 4 2 CHANNELS mode 2 DMX channels 1 Output Channel 1 Output Channel 2 Output Channel 3 Output Channel 4...

Page 40: ...Proportional dimmer from min to max 3 OUTPUT CHANNEL 2 DMX value Function 000 255 Proportional dimmer from min to max 4 OUTPUT CHANNEL 3 DMX value Function 000 255 Proportional dimmer from min to max...

Page 41: ...mer from min to max 4 OUTPUT CHANNEL 5 OUTPUT CHANNEL 6 DMX value Function 000 255 Proportional dimmer from min to max 5 OUTPUT CHANNEL 7 OUTPUT CHANNEL 8 DMX value Function 000 255 Proportional dimme...

Page 42: ...m min to max 2 OUTPUT CHANNEL 2 DMX value Function 000 255 Proportional dimmer from min to max 3 OUTPUT CHANNEL 3 DMX value Function 000 255 Proportional dimmer from min to max 4 OUTPUT CHANNEL 4 DMX...

Page 43: ...NOT use aggressive chemicals solvents or abrasive detergents to clean the product If the product does not work the way it is meant to please contact the nearest authorized support center or refer dir...

Page 44: ...ly remove the dust The LEDs intensity of the connected projectors to DRIVENET is too low Too many devices connected or wrong setup Make sure the DRIVENET is not overloaded by having too many devices c...

Page 45: ...User Manual Ver 1 00 43 di 43 DRIVENET NOTES...

Page 46: ......

Page 47: ......

Reviews: