9
D)
Alarm Mode
Scroll down one level and select by pressing the ENT button ALARM OFF,
CONTINUOUS, TIMED MODE or PULSE MODE.
1)
Alarm OFF
The alarm facility connected to the PCB relay output will not be active.
2)
Continuous
The alarm facility connected to the PCB relay output will give a continuous
alarm/siren output when the alarm is triggered.
3)
Timed mode
The alarm facility connected to the PCB relay output will give a 3 minute
alarm/siren output when the alarm is triggered.
4)
Pulse mode
The alarm facility connected to the PCB relay output will give a 1 second pulse
alarm/siren output when the alarm is triggered.
On all the above, scroll down to MENU EXIT and press ENT to exit.
---------------------------------------------------------------------------------------
From TEST MODE, scroll down to
PROFILES
and press ENT. Screen will display:-
CUSTOMS, HI ACCESS or DOMESTIC & 100-400Kg or 400-700Kg or 700-1000Kg.
1 – Customs,
press ENT button.
Scroll and select either, SPEED Mmin, Acc/Dec mm, LOAD=, COLL=, SBEAM and press
ENT button.
a)
SPEED
•
Press ENT and start to select the following:-
•
OPEN=, press ENT and an arrow will appear next to OPEN=.
•
Select speed from Min. 8 M/min. to Max. 28 M/min with UP & Down buttons.
•
Press ENT button on desired speed.
•
Scroll down to CLOSE=, press ENT and select desired speed as above
(Close Min. speed cannot be greater than Open Min. speed)
•
Press ENT button on desired speed.
•
Scroll down to CREEP=, press ENT button and an arrow will appear next to CREEP=.
•
Select creep speed from Min. 1.5M/min to Max. 4M/min.
•
Press ENT button on desired speed.
•
Scroll down to CAL and press ENT button, an arrow will appear next to CAL.
•
Select calibrating speed from Min. 5 M/min to Max. 8M/min.
•
Press ENT button on desired speed.
•
Scroll down to MENU BACK and press ENT three times to exit.
b)
Acc/Dec
•
Press ENT and start to select the following:-
•
ACC= (Accelerating distance in mm) press ENT and an arrow will appear next to ACC=.
•
Select the distance from Min. 50MM to Max. 500mm
•
Press ENT button on desired distance.
•
Scroll down to DEC= and press ENT and an arrow will appear next to DEC=.
•
Select with UP or Down buttons the required distance from Min. 300MM to Max. 990mm.
•
Press ENT button on desired distance.
•
Scroll down to NORM CLOSE or POS CLOSE (Presently not in use), press ENT to select
the required CLOSE.
(Select at present only NORM CLOSE)
a)
Norm Close, Gate must not bump in close or open position. (+- 15 – 20 mm Gap)