11
4 – Lrn Master
•
Follow the same steps as for
Lrn Gate
.
---------------------------------------------------------------------------------------------------
Remote Programming using Master Remote
(Gate must be in the close position)
•
Press the master remote button, buzzer will emit a continuous beep for 5 seconds.
•
During that 5 seconds, press the new remote button. Continuous beep changes to rapid
beeps for 5 seconds.
•
During that 5 seconds, press the same remote button again to validate the remote.
•
Successful programming will be acknowledged by 2 or 3 beeps.
•
If 3 x 100ms beeps are emitted on the pressing of the master remote, gate is not in the
close position.
•
If 1 x 2 second beep emits on pressing the remote button, RX memory is full. (Max. 500)
•
If 4 x 100ms beeps are emitted on pressing the remote button, remote is already in
memory.
•
If new remote validation failed, rapid beeping will stop without the acknowledged 2 or 3
beeps being emitted.
---------------------------------------------------------------------------------------------------
5 – Delete
•
Once you have pressed the ENT button.
•
Press the transmitter button that you want to delete.
•
The transmitter location will appear next to LOC=, EG LOC=4.
•
Press the ENT button and that remote will show as delete.
•
If the transmitter is not available but the number is known.
•
Scroll down to LOC= and press ENT button.
•
An arrow will appear next to LOC=.
•
Use the UP or Down buttons to select the required transmitter button.
•
Press the ENT button and scroll up to DELETE.
•
Press the ENT button and that transmitter number will be indicated as deleted.
•
Press ENT on MENU BACK to exit.
6 – Delete All
(Master erase)
•
Once you have pressed the ENT button.
•
Scroll to select YES or NO and press the ENT button.
•
If No was selected, the display will go back to Main Menu.
•
If YES was selected, the system will delete ALL possible 500 transmitters.
------------------------------------------------------------------------------------------------------
From TEST MODE, scroll down to
RUN STATUS
and press ENT. Screen will display:-
TR (Triggered by EG. transmitter.)
LS (Open or Close limit switch)
MAINS ON or OFF
BATT (Whatever the battery voltage is, EG 12.2V)
Press ENT to exit.
-------------------------------------------------------------------------------------------------------
From TEST MODE, scroll down to
GEN STATUS
and press ENT. Screen will display:-
ER (Flashing Error number and Description of error)
OP (Number of Operations)
OL (Number of Overloads)
PU (Number of times unit was powered up)
Press ENT to exit.