7.1 Error Codes
Display
Description
Remark
Edge monitoring
Monitoring failure of safety edge if this function is activated. Check
or adjust safety edge.
Run time
Door is stopped on run time control.
Service
Service counter decremented to 0.
Reset for new countdown.
Photo
Failure in photo circuit.
(Test cycle after last stop failed, Press stop to start new test)
Safety edge
Failure in edge circuit.
(Test cycle after last stop failed, Press stop to start new test)
Encoder
Door started, but the position is not changing.
Door is stopped after delay time and E:09 failure is shown about 1
sec (see parameter 81).
Both limits shall be founded again by hold
-
to
-
run steps or both limits
must be relearned.
EEPROM
EEPROM failure of powerup.
Try factory clear or change processor.