The first press of the button turns circuit on, and the next press turns 

circuit off.

KEYPAD FUNCTIONS

KEYPAD FUNCTIONS

Toggle:

The circuit is on while the button is held down.

Momentary:

Momentary Interlock:

The circuit is on while the button is held down but will not turn on while 

an interlock circuit is on.

Constant/Always ON:

The circuit is always on.

Countdown:

The circuit is turned on with the first press of button, and then after a 

predetermined time in seconds the circuit will automatically turn OFF.

Toggle/Dimmer:

The first press turns the pin ON. Holding the button down on the second 

press will decrease voltage on pin until zero power is reached. Pressing 

the button a third time will turn pin OFF.

One-hot Scroll:

One press of the button turns on one circuit, and then each additional 

press turns on a different circuit. Only one circuit is activated at a time. 

The last press turns off all circuits.

Reverse Inclusive Scroll:

With the first press of a button, all circuits are turned on. Each press 

thereafter turns off one circuit. The last press turns off all circuits.

Page 8: DSS-PM8_SpecSheet_V.0920_A

www.digitalswitching.com.au

Summary of Contents for POWERMATE 8

Page 1: ...multitude of applications which allows customisation for distinct digital controlling and monitoring If optimal safety cost reduction and improved adaptability is imperative to you then the POWERMATE...

Page 2: ...ach switched to Battery ONLY 8 Digital Sense Inputs 5 30V DC 4 Resistive Analog Inputs 300 5K ohms 2 Voltage Analog Inputs 0 30V DC Over current Protection on All Outputs Software Settable Soft Start...

Page 3: ...Mate 8 is a digital switching solution developed for the transportation market It provides in one package state of the art digital switching technology and an easy to understand user interface for des...

Page 4: ...nput 6 J1 8 Binput 7 Binput 7 J1 7 Binput 8 Binput 8 DEUTSCH Function ANALOG INPUT Circuit NAME Sense J2 12 Analog 1 Analog 1 300R 5K J2 11 Analog 2 Analog 2 300R 5K J2 8 Analog 3 Analog 3 300R 5K J2...

Page 5: ...Inputs PowerMate 8 has one RS 485 channel It can communicate with other PowerMate Series Digital Switching modules and Keypads within the system network using the OmniBus Interface OMNIBUS INTERFACE...

Page 6: ...and secure with the nut and washer provided Take care to never reverse the terminal connections or reverse the order of connection Do NOT exceed recommended torque ratings as advertised of 12 3 in lb...

Page 7: ...F13 12P 2x Studs 1x Battery 1x Ground Deutsch 2 x DT06 12S 1x A 1xB MECHANICAL ENVIRONMENTAL MECHANICAL ENVIRONMENTAL DIMENSIONS DIMENSIONS 145 00 164 59 145 00 88 40 146 60 119 40 R 5 0 0 14 00 6 00...

Page 8: ...e circuit will automatically turn OFF Toggle Dimmer The first press turns the pin ON Holding the button down on the second press will decrease voltage on pin until zero power is reached Pressing the b...

Page 9: ...V J2 5 J2 6 J1 2 1 1 J1 3 J1 1 2 2 J1 4 J1 12 3 3 J1 5 J1 11 4 4 J1 6 J1 10 5 5 J2 1 J1 9 6 6 J2 2 J1 8 7 7 J2 3 J1 7 8 8 J2 4 Ohm V J2 12 A1 J2 11 A2 V J2 10 A5 V J2 9 A6 J2 8 A3 CANL J2 8 J2 7 A4 C...

Page 10: ...too low for Device 1 Verify Output Device is working properly 2 Check for Short Circuit in Wiring Harness 3 Verify Circuit Breaker value is sufficient for System INDICATOR LED S FLICKER ON AND OFF 1 F...