background image

Page 9: DSS-PM8_SpecSheet_V.0920_A

Batt

J1

J2

Gnd

CONNECTION DIAGRAM

CONNECTION DIAGRAM

+

-

www.digitalswitching.com.au

CAN Bus

Device

Switchable

CB 8OA

Circuit

5A

Breaker

Keypad 1

Keypad 2

Keypad 3

KPD_PWR

GND

V+

V-

J2-5

J2-6

J1-2

1

1

J1-3

J1-1

2

2

J1-4

J1-12

3

3

J1-5

J1-11

4

4

J1-6

J1-10

5

5

J2-1

J1-9

6

6

J2-2

J1-8

7

7

J2-3

J1-7

8

8

J2-4

Ohm/V

Ώ

J2-12

A1

Ώ

J2-11

A2

V

J2-10

A5

V

J2-9

A6

Ώ

J2-8

A3

CANL

J2-8

Ώ

J2-7

A4

CANH

J2-9

B

IN

A

R

IN

P

U

TS

P

O

W

ER

 O

U

TP

U

TS

P

O

W

ERA

N

A

LO

G

OPTION

+V

POS

STUD

-V

NEG

STUD

SENSE

STB/STG

O.C.

AMPS

OMNI-BUS

* Illustration Example Only

ANALOG

POWER

POWER OUTPUTS

BINAR

Y

 INPUTS

Summary of Contents for POWERMATE 8

Page 1: ...multitude of applications which allows customisation for distinct digital controlling and monitoring If optimal safety cost reduction and improved adaptability is imperative to you then the POWERMATE...

Page 2: ...ach switched to Battery ONLY 8 Digital Sense Inputs 5 30V DC 4 Resistive Analog Inputs 300 5K ohms 2 Voltage Analog Inputs 0 30V DC Over current Protection on All Outputs Software Settable Soft Start...

Page 3: ...Mate 8 is a digital switching solution developed for the transportation market It provides in one package state of the art digital switching technology and an easy to understand user interface for des...

Page 4: ...nput 6 J1 8 Binput 7 Binput 7 J1 7 Binput 8 Binput 8 DEUTSCH Function ANALOG INPUT Circuit NAME Sense J2 12 Analog 1 Analog 1 300R 5K J2 11 Analog 2 Analog 2 300R 5K J2 8 Analog 3 Analog 3 300R 5K J2...

Page 5: ...Inputs PowerMate 8 has one RS 485 channel It can communicate with other PowerMate Series Digital Switching modules and Keypads within the system network using the OmniBus Interface OMNIBUS INTERFACE...

Page 6: ...and secure with the nut and washer provided Take care to never reverse the terminal connections or reverse the order of connection Do NOT exceed recommended torque ratings as advertised of 12 3 in lb...

Page 7: ...F13 12P 2x Studs 1x Battery 1x Ground Deutsch 2 x DT06 12S 1x A 1xB MECHANICAL ENVIRONMENTAL MECHANICAL ENVIRONMENTAL DIMENSIONS DIMENSIONS 145 00 164 59 145 00 88 40 146 60 119 40 R 5 0 0 14 00 6 00...

Page 8: ...e circuit will automatically turn OFF Toggle Dimmer The first press turns the pin ON Holding the button down on the second press will decrease voltage on pin until zero power is reached Pressing the b...

Page 9: ...V J2 5 J2 6 J1 2 1 1 J1 3 J1 1 2 2 J1 4 J1 12 3 3 J1 5 J1 11 4 4 J1 6 J1 10 5 5 J2 1 J1 9 6 6 J2 2 J1 8 7 7 J2 3 J1 7 8 8 J2 4 Ohm V J2 12 A1 J2 11 A2 V J2 10 A5 V J2 9 A6 J2 8 A3 CANL J2 8 J2 7 A4 C...

Page 10: ...too low for Device 1 Verify Output Device is working properly 2 Check for Short Circuit in Wiring Harness 3 Verify Circuit Breaker value is sufficient for System INDICATOR LED S FLICKER ON AND OFF 1 F...

Reviews: