11
the function, select "Enable "option and press the" Submit "button; instead, select" Disable "option.
2. 100V constant voltage backup function: a. Without network; if chose “Enable” before, when the network
play is abnormal or the terminal drops, it will switch to 100V audio signal automatically; if chose
“Disable” before, when the network is abnormal, it will not switch to 100V audio signal. b. Without Power;
whether chose “Enable” or “Disable” before, it will switch to 100V audio signal automatically.
3. On-demand panel terminal function: to ensure that there is no switch to 100V state, select "fixed" option
for the terminal being fixed for the on-demand panel terminal, and when select the "dynamic" option, plug
in the on-demand panel for the on-demand panel terminal; not inserted for the ordinary playback terminal.
4. Local network preference: Three priority modes. to ensure that there is no switch to 100V state, when the
"local" option is selected, the local source is output first, and the "network" option is the same. When
"mixed" is selected, both local and network are output at the same time.
5. Microphone type selection: According to their own needs to select the condenser or dynamic type to ensure
that there is no switch to 100V state.