background image

*

*

Network PA System

4

1 Network interface (LAN1/LAN2)

Dual Network design to connect with Network
POE.

2 USB interface (USB Disk)

Insert U disk or mobile hard disk with MP3
program inside to provide MP3player with program.

3 SD card interface (Micro SD)

If the inserted SD card has timing points, host will
play program when terminal is offline.

4 Auxiliary input interface (AUX IN)

To connect with audio source equipment (such as
DVD) to extend program source.

5 EMC prior playing output

Output signal of this interface is controlled by host.

6 100V external audio input

To connect with other standby amplifier.

7 Amplifier output (100V)

Built-in 1×60W digital amplifier with rated power
60W to connect with multiple speakers. Total power
of connected speakers should be no more than 60W.

8

On-demand terminal connection interface

To connect with on-demand terminal by using
8-core Network cable. Connection instruction
please refer to User Manual of on-demand terminal.

9 MIC2 interface

To connect with MIC.

MIC1 sound pickup

Built-in pickup window. Speak to this window to
broadcast.

Auxiliary output interface (AUX OUT)

To connect with other amplifiers to extend power.

12 AC220V power cable

To supply power.

13 Power switch (POWER)

Press “I” to turn on power supply. Press again to
turn off.

14 Heat dissipation

Summary of Contents for MAG6701

Page 1: ...ming Signal 100V Backup Protect VOL VOL Set F1 USB 100V Network Terminal MAG6701 User Manual Thank you for using our DSPPA public address system Please read this User Manual carefully to make better u...

Page 2: ...This page is left blank for the user s notes...

Page 3: ...ctions on use of product and technical specifications of the terminal Please read this User Manual carefully before connection installation and use and operate in accordance with corresponding instruc...

Page 4: ...ase disconnect other equipment from power source before they are connected to this product Please tune volume to its minimum level before the device is powered ON or OFF All terminals on the device ma...

Page 5: ...oduction to remote controller 5 3 Connection Diagram 6 3 1 Application of MAG6701 in Network PA system 6 3 2 MAG6701 connection diagram 6 4 Operation Instruction 8 5 Installation 8 6 Operating Instruc...

Page 6: ...amplifiers to extend power There is also a MIC interface to realize local paging 1 2 Features Dual network redundancy design able to work cross network segment Able to be installed to any place where...

Page 7: ...execute timing function without host control When executing indicator will be turned on 5 Amplifier output level indicator Signal This indicator will be turned on when there is signal output from thi...

Page 8: ...setting mode move right to view set parameters 15 Digital display screen and receiving window of infrared remote Digital display screen will display working status and Network information There is a...

Page 9: ...al audio input To connect with other standby amplifier 7 Amplifier output 100V Built in 1 60W digital amplifier with rated power 60W to connect with multiple speakers Total power of connected speakers...

Page 10: ...der other status press Enter to confirm 8 Next one CH is used to play next program 9 Cancel Under free status press Cancel to adjust output Treble 0 15 adjustable Under other status press Cancel to ca...

Page 11: ...uxiliary output to connect with other audio sources and power amplifiers The customized design can satisfy demands for high power and multiple audio sources The MP3 player and network audio stream can...

Page 12: ...nput cable cannot be tangled together to avoid signal interference Ethernet switch MIC Connect to a 60W speaker LAN2 LAN1 Micro SD USB Disk MIC1 AUX lN AUX OUT MIC2 24V IN IN A B OUT OUT COM MIN MAX M...

Page 13: ...arameters Press VOL or VOL to increase and decrease After changing press Play Pause key to save parameters If you do not press Play Pause key your change will not be saved 3 IP represents IP address S...

Page 14: ...while the IP address of host computer computer should be 192 168 40 XX Note the setting IP can not appear IP conflict phenomenon 2 Input the IP address of the terminal on IE browser after connecting h...

Page 15: ...IP address of the terminal on IE browser to get into the following page and then click Public Address for a further function setting to the terminal as the picture below 1 Off line schedule function E...

Page 16: ...nal function to ensure that there is no switch to 100V state select fixed option for the terminal being fixed for the on demand panel terminal and when select the dynamic option plug in the on demand...

Page 17: ...n the case and repair without permission from a professional personnel to avoid accident or additional damages to the device Please do NOT place any corrosive chemicals near or on the device 2 Matters...

Page 18: ...1 1 set 2 1500MM AV terminal audio cable 1 pc 3 3000MM 8 core network cable 1 pc 4 User Manual 1 copy 5 Warranty card 1 copy 6 Certificate 1 copy 7 7P green plug 3 81MM plug 1 set 8 8P green plug 2 54...

Page 19: ...onic distortion of the built in power amplifier 1 MIC input Input sensitivity 3 5 mV 1mV Frequency response 80Hz 16kHz 3dB Distortion 0 5 Noise 14mV Signal to noise ratio 77 dB USB SD NET Play MP3 Inp...

Page 20: ...remove the cover of the equipment otherwise you may get an electric shock Where necessary repair to the equipment should be conducted by qualified professionals All terminals on the device marked with...