background image

3

OPERATING PRECAUTIONS

Make sure the AC supply voltage is correct, it means the AC supply voltage must be as the
same as that printed on the rear panel of the amplifier.

Damage caused by connecting the

amplifier to improper AC supply voltage is not covered by the three-year warranty.

Make sure the power switch is off before making any input or output connections.

To prevent speaker damage, it is always a good idea to turn the attenuator to minimum
before turn-on the amplifier if there is a high level signal at its input terminal.

The protection light on while operation means faults (e.g. overload or short-circuit) happening.
The power should be cut off immediately and should not be turn on before correcting the
faults.

Before turn on the device, using OUTPUT VOLTAGE SWITCH to set up the output voltage
value which matches the rated voltage of connecting speakers. The switch cannot be moved
during the operation.

ADDRESS SETTING

In the MAG system, you can connect a total of 32 units of this equipment, equipment set-based link

address is to be distinguished from each device, the address in binary using 8 way jumper settings, as
shown below: Each jumper has three needle, with the jumper's two pins to take the above link is expressed
as a binary "1"; with the jumper to take the under two-pin connecting expressed as a binary "0." The first
device address code is 00001001, which means jumper settings shown in Figure 2; second address code is
00001010, the method of jumper settings shown in Figure 3; other equipment jumper setting method refer
to the first and second set way, and so on, the corresponding address code please refer to the attached pages
(Equipment & Address code corresponding Table).

Input Connections

Audio

input connections are made

via either the

3-pinXLR

-type

connectors (Figure 1) or

6.35mm

sockets on

the rear panel.

Signal (Hot)

Ground (Ring)

Figure1 3-pin XLR-type

1

2

3

1

0

Fig.1

0 0 0 0

0 0

1

1

Fig.3

0 0

0

0

1

0 0

1

Fig.2

Summary of Contents for MAG1306II

Page 1: ...y FEATURES Dual channel amplifier individual volume and tone control for each channel 200V 100V 70V rated power output Clear LED display of operation status multifunctional protection With priority input available in short circuit 3 wire mode output simple wiring system Exchange control signal and status information with MAG Host choose and buy ...

Page 2: ...l AAudio Input TRA 3 Channel B Output R Terminal 13 Channel A EMC In Terminal Available In 4 Channel A Output Common COM Short Circuit 5 Channel A Output HOT HOT 14 Output Voltage Switch 6 Channel A Output R Terminal 15 Intelligent communication interface option 7 Outtake 16 Address jumper 8 Channel B EMC IN Terminal 17 Intelligent communication link interface option Available In Short Circuit 18 ...

Page 3: ... The switch cannot be moved during the operation ADDRESS SETTING In the MAG system you can connect a total of 32 units of this equipment equipment set based link address is to be distinguished from each device the address in binary using 8 way jumper settings as shown below Each jumper has three needle with the jumper s two pins to take the above link is expressed as a binary 1 with the jumper to ...

Page 4: ... should be connected with COM and HOT terminals directly using broadcast line Speakers with volume controller should be connected with this amplifier s COM terminal and volume controller s SP terminal Volume controller s SP terminal R terminal and HOT terminal should be connected with the same terminals on this amplifier Please refer to Rear Panel and Connections diagram The connecting speakers sh...

Page 5: ...rature DC voltage Output Circuit Shorting Power Requirement AC220 240V 50 60Hz Power Consumption 100W 200W 400W 600W Outer Packing Size mm L W H 535 525 195 Unit Size mm L W H 483 443 88 Gross Weight 18 1kg 20 6kg 24 6kg 26 7kg Net Weight 15 6kg 18kg 22kg 24 2kg Specifications are subject to change without notice CAUTION When the Power switcher is off please pull out the power cord from the socket...

Page 6: ... 00011100 5 0xd 00001101 21 0x1d 00011101 6 0xe 00001110 22 0x1e 00011110 7 0xf 00001111 23 0x1f 00011111 8 0x10 00010000 24 0x20 00100000 9 0x11 00010001 25 0x21 00100001 10 0x12 00010010 26 0x22 00100010 11 0x13 00010011 27 0x23 00100011 12 0x14 00010100 28 0x24 00100100 13 0x15 00010101 29 0x25 00100101 14 0x16 00010110 30 0x26 00100110 15 0x17 00010111 31 0x27 00100111 16 0x18 00011000 32 0x28...

Reviews: