background image

ADD-ONS

Comparison of equipment with address

Equip.

MAG host

Coding

Equip.

MAG host

Coding

1

0x09

00001001

17

0x19

00011001

2

0xa

00001010

18

0x1a

00011010

3

0xb

00001011

19

0x1b

00011011

4

0xc

00001100

20

0x1c

00011100

5

0xd

00001101

21

0x1d

00011101

6

0xe

00001110

22

0x1e

00011110

7

0xf

00001111

23

0x1f

00011111

8

0x10

00010000

24

0x20

00100000

9

0x11

00010001

25

0x21

00100001

10

0x12

00010010

26

0x22

00100010

11

0x13

00010011

27

0x23

00100011

12

0x14

00010100

28

0x24

00100100

13

0x15

00010101

29

0x25

00100101

14

0x16

00010110

30

0x26

00100110

15

0x17

00010111

31

0x27

00100111

16

0x18

00011000

32

0x28

00101000

Summary of Contents for MAG1306II

Page 1: ...y FEATURES Dual channel amplifier individual volume and tone control for each channel 200V 100V 70V rated power output Clear LED display of operation status multifunctional protection With priority input available in short circuit 3 wire mode output simple wiring system Exchange control signal and status information with MAG Host choose and buy ...

Page 2: ...l AAudio Input TRA 3 Channel B Output R Terminal 13 Channel A EMC In Terminal Available In 4 Channel A Output Common COM Short Circuit 5 Channel A Output HOT HOT 14 Output Voltage Switch 6 Channel A Output R Terminal 15 Intelligent communication interface option 7 Outtake 16 Address jumper 8 Channel B EMC IN Terminal 17 Intelligent communication link interface option Available In Short Circuit 18 ...

Page 3: ... The switch cannot be moved during the operation ADDRESS SETTING In the MAG system you can connect a total of 32 units of this equipment equipment set based link address is to be distinguished from each device the address in binary using 8 way jumper settings as shown below Each jumper has three needle with the jumper s two pins to take the above link is expressed as a binary 1 with the jumper to ...

Page 4: ... should be connected with COM and HOT terminals directly using broadcast line Speakers with volume controller should be connected with this amplifier s COM terminal and volume controller s SP terminal Volume controller s SP terminal R terminal and HOT terminal should be connected with the same terminals on this amplifier Please refer to Rear Panel and Connections diagram The connecting speakers sh...

Page 5: ...rature DC voltage Output Circuit Shorting Power Requirement AC220 240V 50 60Hz Power Consumption 100W 200W 400W 600W Outer Packing Size mm L W H 535 525 195 Unit Size mm L W H 483 443 88 Gross Weight 18 1kg 20 6kg 24 6kg 26 7kg Net Weight 15 6kg 18kg 22kg 24 2kg Specifications are subject to change without notice CAUTION When the Power switcher is off please pull out the power cord from the socket...

Page 6: ... 00011100 5 0xd 00001101 21 0x1d 00011101 6 0xe 00001110 22 0x1e 00011110 7 0xf 00001111 23 0x1f 00011111 8 0x10 00010000 24 0x20 00100000 9 0x11 00010001 25 0x21 00100001 10 0x12 00010010 26 0x22 00100010 11 0x13 00010011 27 0x23 00100011 12 0x14 00010100 28 0x24 00100100 13 0x15 00010101 29 0x25 00100101 14 0x16 00010110 30 0x26 00100110 15 0x17 00010111 31 0x27 00100111 16 0x18 00011000 32 0x28...

Reviews: