SIP Intercom System
6
/ 47
1.
Confirm the connection
Confirm whether the equipment of the power cord, network cable, electric lock control line
connection and the boot-up is normal. (Check the network state of light)
1)
Power, Electric Lock, Indoor switch port
Door phone the power supply ways: 12v/DC or POE.
CN7
1
2
3
4
5
6
7
+12V
VSS
NC
COM
NO
S_IN
S_OUT
12V 1A/DC
Electric-lock switch
Indoor switch
2)
Driving mode of electric-lock(Default in active mode)
【
Note
】
When the device is in active mode, it can drive 12V/700mA switch output maximum, to which a
standard electric-lock or another compatible electrical appliance can be connected.
When using the active mode, it is 12V DC in output.
When using the passive mode, output is short control (normally open mode or normally close mode).
3)
Wiring instructions
NO: Normally Open Contact.
COM: Common Contact.
NC: Normally Close Contact.
Driving Mode
Electric lock
Jumper port
Connections
Active Passive
No
electricity
when open
When the
power to open
Jumper in passive mode
Jumper in active mode