DSM VF-150 OEM User Manual Download Page 5

 
 
 
 

 

 

 

Hard

ware Version V

131028

 

4

 

205 Williamson Square

 

Franklin, TN  37064

 

Tel: 615/595

-

6665

 

Fax: 615/595

-

6610

 

114 Southeast Parkway Ct. 

Ste 160

 

Franklin, TN  37064

 

Tel: 615/595

-

6665

 

Fax: 615/595

-

6610

 

Instructions for Use

 

 

Start

-

Up / Shut

-

Down Procedure

:

 

D

SM recommends that the unit

 

be connected to a load (capacitive, such as a piezoelectric device 

of the appropriate rating) during 

start

-

up and while the unit

 

is running; operating without a load 

can be damaging to the unit

’s circuitry.

 

 

Attach a standard load (i.e., a piezoelectric actuator with two lead wires for 

power

 

and ground) to 

the 

VF

-

150

 

OEM

.  Typically, the piezoelectric material manufac

turer will designate the “live”,

 

“hot” 

or “positive” 

electrode with red lead wi

re and/or a visible mark on the piezo material to 

distinguish this electrode from the ground electrode.

 

 

  

CAUTION:  When the 

VF

-

150

 

OEM

 

is powered, 

pins

 

can have

 

voltages

 

up to 

200

 

V

 

(depend

ing

 

on power supply used)

.

 

 

VF

-

150 OEM

 

Mounting and Connection Diagram

:

 

 

(

top side of 

customer supplied

 

board pictured

)

 

 

 

Connections

:

 

 

CN201

 

(20 pin connector)

 

PN 

FCI 

10106813

-

021112LF

 

1, 2

 

 

A

nalog I

nput

 

3, 4

 

 

A

nalog Ground

 

5, 6

 

 

Amplifier

 

TX

 

 

7, 8

 

 

Amplifier

 

RX

 

9, 10

 

 

DAC CS

 

11, 12

 

 

DAC MOSI

 

13, 14

 

 

DAC CLK

 

15 thru 18

 

 

D

igital Ground

 

19, 20 

 

 

5VDC 1A 

 

*L

ogic inputs are 3.3 and 5

 

V tolerant.

 

*Outputs are 5

 

V logic level

 

Reviews: