DSE DSE9130 Operator'S Manual Download Page 45

Specifications 

43 

 

3.7  APPLICABLE STANDARDS 

 

BS 4884-1 

This document conforms to BS4884-1 1992 Specification for 
presentation of essential information. 

BS 4884-2 

This document conforms to BS4884-2 1993 Guide to content. 

BS 4884-3 

This document conforms to BS4884-3 1993 Guide to presentation. 

BS EN 60068-2-1 

 (Minimum temperature)

 

-30

°

C (-22

°

F) 

BS EN 60068-2-2 

 (Maximum temperature)

 

+55

°

C (131

°

F) 

BS EN 60950

  

Safety of information technology equipment, including electrical 
business equipment. 

BS EN 61000-6-2

  

EMC Generic Immunity Standard (Industrial). 

BS EN 61000-6-4

  

EMC Generic Emission Standard (Industrial). 

BS EN 60529

  

(Degrees of protection 
provided by enclosures)

 

IP20 
 
Protected against penetration by solid objects with a diameter of more 
than 12 mm. Fingers or similar objects prevented from approach. 
 
No protection against water 

UL508  
NEMA rating

 

Enclosure type 1 
 
Provides a degree of protection against contact with the enclosure 
equipment and against a limited amount of  falling dirt 

UK WEEE 
REGULATIONS 

Producer Registration Number WEE/BE0052TQ 

 
In line with our policy of continual development, Deep Sea Electronics, reserve the right to change specification without notice. 

 

Summary of Contents for DSE9130

Page 1: ...arkets including heavy and light industrial environments ENVIRONMENTAL TESTING STANDARDS ELECTRO MAGNETIC COMPATIBILITY BS EN 61000 6 2 EMC Generic Immunity Standard for the Industrial Environment BS...

Page 2: ...NE 1 815 316 8706 FACSIMILE 1 815 316 8708 EMAIL sales deepseausa com WEBSITE www deepseausa com 055 059 10 10 7 RELATED MATERIALS TITLE PART NO S DSE9000 Series Installation Instructions 053 049 DSE9...

Page 3: ...DSE9000 Series Battery Charger Operator Manual ISSUE 13 DEEP SEA ELECTRONICS PLC DSE9000 SERIES BATTERY CHARGER OPERATOR MANUAL Document Number 057 085 Author Ashley Senior...

Page 4: ...nce to trademarked product names used within this publication is owned by their respective companies Deep Sea Electronics Plc reserves the right to change the contents of this document without prior n...

Page 5: ...6 3 5 12 DSE9481 MKII 12V 5A 28 3 6 DIMENSIONS AND MOUNTING 29 3 6 1 DSE907 12V 10A INDUSTRIAL BATTERY CHARGER 29 3 6 2 DSE908 12V 24V 10A CABINET MOUNTED BATTERY CHARGER 30 3 6 3 DSE9130 12V 5A 31 3...

Page 6: ...6 1 2 PSU MODE 56 6 1 3 CHARGE MODE 56 6 1 4 BOOST MODE 57 6 2 OPERATION OF DSE9400 MKII SERIES 58 6 2 1 PROTECTION 58 6 2 2 DIGITAL INPUT 59 6 2 3 VOLTAGE ADJUSTMENT POTENTIOMETER 59 6 2 4 PSU MODE 5...

Page 7: ...TION INSTRUCTIONS Installation instructions are supplied with the product in the box and are intended as a quick start guide only DSE PART DESCRIPTION 053 049 DSE9200 DSE9400 Series Battery Charger In...

Page 8: ...to them for reference purposes This is not a controlled document You will not be automatically informed of updates Any future updates of this document will be added to the DSE website at www deepseapl...

Page 9: ...chargers This change must be made at the DSE factory Ensure the correct variant and float voltage if applicable is specified on ordering Consult your battery manufacturer for further details of requi...

Page 10: ...ade at the DSE factory Ensure the correct variant and float voltage if applicable is specified on ordering Consult your battery manufacturer for further details of required float voltage Product type...

Page 11: ...tware Part number 9470 001 00 is fixed at 24V 10A Part number 9480 001 00 is fixed at 12V 10A NOTE DSE9400 series battery chargers are customer configurable via the DSE Configuration Suite PC Software...

Page 12: ...attery chargers factory fitted into wall mounted enclosures For details see the section entitled Dimensions and Mounting elsewhere in this document 0907 002 02 INDUSTRIAL BATTERY CHARGER 12V 5A 220 25...

Page 13: ...Hz 64Hz Output Ripple and Noise DSE9100 Series DSE9200 Series DSE9400 Series 1 Vo 2 Vo 1 Vo Load Regulation DSE9100 Series DSE9200 Series DSE9400 Series 1 Vo 2 Vo 1 Vo Line Regulation 0 01 Vo Output V...

Page 14: ...ection between a PC and the DSE9400 series battery charger Using the DSE Configuration Suite Software the operator is then configure and monitor the state of the battery charger To connect a DSE9400 s...

Page 15: ...2 MODBUS RTU RS485 is used for point to point cable connection of more than one device maximum 32 devices and allows for connection to PCs PLCs and Building Management Systems to name just a few devi...

Page 16: ...bled Brainboxes VX 023 ExpressCard 1 Port RS422 485 for laptops and nettop PCs Brainboxes UC320 PCI Velocity RS485 card for desktop PCs Set to Half Duplex Autogating with CTS True set to enabled Brain...

Page 17: ...0V Specify float voltage on ordering Output Charging Current A 0A 5A 5 5A Current limit threshold A 5A 5 3A 5 5A Recovery from current limit A 5A Full load AC input current A 1 5A With output at 13 7...

Page 18: ...Current limit threshold A 10A 11A Recovery from current limit A 10A 11A Full load AC input current A 3 1A At Vin 85V Vo 13 7V Io 10Amp Full load AC input current A 1 3A At Vin 230V Vo 13 7V Io 10Amp...

Page 19: ...Output Voltage 12 V DC Battery 12 5V 13 7V 13 7V Float voltage not adjustable Output Charging Current A 0A 2A 2 5A Current limit threshold A 2A 2 3A 2 5A Recovery from current limit A 2A Full load AC...

Page 20: ...ltage 12 V DC Battery 12 5V 13 7V 13 7V Float voltage not adjustable Output Charging Current A 0A 3A 3 5A Current limit threshold A 3A 3 2A 3 5A Recovery from current limit A 3A Full load AC input cur...

Page 21: ...8 0V 34 3V 34 5 Output Charging Current A 0A 2 2A 3A Current limit threshold A 2A 2 2A 3A Recovery from current limit A 2A Full load AC input current A 2A AC Input Inrush 10ms current A 30A 0 78 0 8 0...

Page 22: ...DC Battery 25 0V 27 4V 30 0V Specify float voltage on ordering Output Charging Current A 0A 3 7A 4A Current limit threshold A 3 6A 3 75A 4A Recovery from current limit A 3 6A Full load AC input curre...

Page 23: ...voltage on ordering Output Charging Current A 0A 5A Current limit threshold A 5A 5 3A 6A Recovery from current limit A 5A 5 2A Full load AC input current A 0 65A 2 7A With output at 27 6V DC AC Input...

Page 24: ...t limit threshold A 10A 11A Recovery from current limit A 9 5A 10A 11A Full load AC input current A 2 2A At Vin 230V Vo 27 6V Io 10Amp Full load AC input current A 5 8A At Vin 85V Vo 27 6V Io 10Amp AC...

Page 25: ...Current A 2A 10A 11A Current limit threshold A 10A 11A Recovery from current limit A 10A 11A Full load AC input current A 2 3A At Vin 230V Vo 28 8V Io 10Amp Full load AC input current A 4A At Vin 110V...

Page 26: ...Specifications 24 0 0 1 0 2 0 3 0 4 0 5 0 6 0 30 20 10 0 10 20 30 40 50 60 70 80 90 100 Output Current A Ambient Temperature C DSE9470 Smart Charger De rating Curve 95V Vin 110V...

Page 27: ...it A 5A 5 5A Full load AC input current A 1 2A At Vin 230V Vo 28 8V Io 5Amp Full load AC input current A 2 2A At Vin 110V Vo 28 8V Io 5Amp AC Input Inrush 10ms current A 60A For 10ms 89 90 90 91 91 92...

Page 28: ...harging Current A 2A 10A 11A Current limit threshold A 10A 11A Recovery from current limit A 10A 11A Full load AC input current A 1 2A At Vin 230V Vo 14 4V Io 10Amp Full load AC input current A 2 2A A...

Page 29: ...Specifications 27 0 0 1 0 2 0 3 0 4 0 5 0 6 0 30 20 10 0 10 20 30 40 50 60 70 80 90 100 Output Current A Ambient Temperature C DSE9470 Smart Charger De rating Curve 95V Vin 110V...

Page 30: ...mit A 5A Full load AC input current A 0 5A At Vin 230V Vo 14 4V Io 5Amp Full load AC input current A 1 1A At Vin 110V Vo 14 4V Io 5Amp AC Input Inrush 10ms current A 60A For 10ms 89 89 90 90 91 91 92...

Page 31: ...l bracket add 20mm 0 79 to the depth of the enclosure Mounting holes Diameter 5mm 0 2 130mm 5 1 centres Input voltage nominal 110V 277V Input voltage absolute range 90V 305V Charge failure relay ratin...

Page 32: ...outside in textured RAL 7035 Protection category IP20 NEMA 1 Weight 15kg Mounting type Wall mounting Can be mounted by customer drilled holes or by using Rittal mounting brackets suitable for Rittal...

Page 33: ...with the terminal strips at the bottom Parameter Comment Overall size 136 48mm x 140 41mm x 63 40mm 5 37 x 5 53 x 2 5 Weight 0 5kg Mounting type DIN rail or chassis mounting Din rail type EN 50022 35m...

Page 34: ...signed to be mounted with the base to a vertical surface with the terminal strips at the bottom Parameter Comment Overall size 108 03mm x 101 10mm x 48 6mm 4 25 x 3 98 x 1 91 Weight 0 16kg Mounting ty...

Page 35: ...gned to be mounted with the base to a vertical surface with the terminal strips at the bottom Parameter Comment Overall size 108 03mm x 101 10mm x 48 6mm 4 25 x 3 98 x 1 91 Weight 0 16kg Mounting type...

Page 36: ...nting type DIN rail or chassis mounting Din rail type EN 50022 35mm type only Mounting holes Suitable for M4 Mounting hole centres 142mm x 128mm 5 59 x 5 0 30mm 1 18 from top and bottom edges 5mm 1 97...

Page 37: ...with the terminal strips at the bottom Parameter Comment Overall size 136 48mm x 140 41mm x 63 40mm 5 37 x 5 53 x 2 5 Weight 0 5kg Mounting type DIN rail or chassis mounting Din rail type EN 50022 35m...

Page 38: ...nted with the base to a vertical surface with the terminal strips at the bottom Parameter Comment Overall size 136 48mm x 140 41mm x 63 40mm 5 37 x 5 53 x 2 5 Weight 0 5kg Mounting type DIN rail or ch...

Page 39: ...with the terminal strips at the bottom Parameter Comment Overall size 136 48mm x 140 41mm x 63 40mm 5 37 x 5 53 x 2 5 Weight 0 5kg Mounting type DIN rail or chassis mounting Din rail type EN 50022 35m...

Page 40: ...mm 6 0 x 7 4 x 2 44 Weight 0 85kg Mounting type DIN rail or chassis mounting Din rail type EN 50022 35mm type only Mounting holes Suitable for M4 Mounting hole centres 142mm x 128mm 5 59 x 5 0 Input v...

Page 41: ...05mm x 135mm x 80mm 8 0 x 5 3 x 3 1 Weight 0 78kg Mounting type DIN rail or chassis mounting Din rail type EN 50022 35mm type only Mounting holes Suitable for M4 Mounting hole centres 190mm x 120mm 7...

Page 42: ...05mm x 135mm x 80mm 8 0 x 5 3 x 3 1 Weight 0 7kg Mounting type DIN rail or chassis mounting Din rail type EN 50022 35mm type only Mounting holes Suitable for M4 Mounting hole centres 190mm x 120mm 7 5...

Page 43: ...05mm x 135mm x 80mm 8 0 x 5 3 x 3 1 Weight 0 7kg Mounting type DIN rail or chassis mounting Din rail type EN 50022 35mm type only Mounting holes Suitable for M4 Mounting hole centres 190mm x 120mm 7 5...

Page 44: ...05mm x 135mm x 80mm 8 0 x 5 3 x 3 1 Weight 0 7kg Mounting type DIN rail or chassis mounting Din rail type EN 50022 35mm type only Mounting holes Suitable for M4 Mounting hole centres 190mm x 120mm 7 5...

Page 45: ...EN 61000 6 2 EMC Generic Immunity Standard Industrial BS EN 61000 6 4 EMC Generic Emission Standard Industrial BS EN 60529 Degrees of protection provided by enclosures IP20 Protected against penetrati...

Page 46: ...of the correct technology to suit the setting of the charger For details of other supported battery types and float voltages see the section entitled Specifications Part Numbering elsewhere in this d...

Page 47: ...ON Ensure Earth Terminal is connected to Battery negative for negative earth systems or Battery positive for positive earth systems Where no system earth exists Earth Terminal must be connected to bat...

Page 48: ...A 0 5 mm AWG 22 CF Charge failure relay 0 5 mm AWG 22 Closes under charge fail conditions CF Charge failure relay 0 5 mm AWG 22 Connector B Terminal Function Recommended Size Earth 1mm AWG 16 N AC Ne...

Page 49: ...ogether to activate the input The Factory Setting for the digital input provides a selection of 12V 24V operation Customer configurable using DSE Configuration Suite PC Software NOTE Digital Input Not...

Page 50: ...0 RS485 approved cable NTC PT1000 connection terminals 0 5mm AWG20 Use only PT1000 NTC 0 5mm AWG20 Connector C Terminal Function Recommended Size Earth 1mm AWG 16 N AC Neutral 1mm AWG 16 L AC Live 1mm...

Page 51: ...ommended AC fuse 230V AC Input 110V AC Input DSE9150 12V 2A charger see Note below DSE9150 12V 3A charger 1 0A anti surge 1 5A anti surge 1 5A anti surge 2 0A anti surge NOTE DSE9150 12V 2A is no long...

Page 52: ...r DSE9140 12V 10A charger DSE9155 30V 2A charger DSE9250 24V 3 7A charger DSE9260 24V 10A charger DSE9255 24V 5A charger 1 0A anti surge 2 0A anti surge 1 0A anti surge 1 0A anti surge 3 5 A anti surg...

Page 53: ...d 9480 001 00 contact DSE Technical Support for connection details Recommended AC fuse DSE9470 24V 12V 10A DSE9480 12V 24V 10A DSE9481 12V 24V 5A DSE9472 24V 12V 5A 230V AC Input 3 5A antisurge 3 5A a...

Page 54: ...nated RED when AC power is connected and the POWER switch is in the 1 position Charge Ammeter Scaled 0A to 10A to show charge current Max 5A charge 5 2 DSE908 Function Action Power indication Illumina...

Page 55: ...E9150 12V 3A LED Indications Function Colour Action Charger Status Red Off when AC supply is not present or output volts are too low Steady during normal operation with AC supply above minimum operati...

Page 56: ...l operation with AC supply above minimum operating voltage Flashing when connected to an operating charging alternator Short circuit and reverse polarity indication Green Off when AC supply is not pre...

Page 57: ...has been disconnected from the battery Off Red Constant Red Constant 5 5 2 CHARGE MODE Mode LED DESIGNATION OPE Bulk Charge in progress Yellow Constant Absorption Charge in progress Yellow Flashing F...

Page 58: ...arity protection Charger automatically restarts operation after the fault is removed 6 1 2 PSU MODE If no battery is connected to the output terminals the DSE9100 DSE9200 series battery charger will o...

Page 59: ...ed Typically a battery will charge from flat to 80 capacity in 16hrs when when charged at C 10 For example charging a 50Ah battery for 16hrs at 5A will charge the battery to 80 of its full capacity Re...

Page 60: ...into two categories Factory Configured non ajustable alarms User Configurable Alarms adjustable by DSE Configuration Suite PC Software 6 2 1 1 FACTORY CONFIGURED ALARMS Under the following conditions...

Page 61: ...e potentiometer adjusts the boost voltage byup to 1 7V This is subject to an absolute maximum of 29 5V The table below shows the effect of the potentiometer on the boost voltage in the various chargin...

Page 62: ...tant level boost voltage to allow the battery to charge while the load does not exceed the maximum rating of the charger If the load on the battery charger battery charge demand standing load exceeds...

Page 63: ...harge the battery until it is fully charged Typically a battery will charge from flat to 80 capacity in 16hrs when when charged at C 10 For example charging a 50Ah battery for 16hrs at 5A will charge...

Page 64: ...is document Charge fail relay continuously operated Check the connected load of the charger is not reverse connected or short circuit Batteries fail to charge Check the batteries using the battery man...

Page 65: ...ct treat recycle and dispose of WEEE separately from your other waste 10 2 ROHS RESTRICTION OF HAZARDOUS SUBSTANCES Directive 2002 95 EC 2006 To remove specified hazardous substances Lead Mercury Hexa...

Page 66: ...This page is intentionally left blank...

Page 67: ...9130 9150 9155 9255 COMPACT BATTERY CHARGERS 2 AMP 5 AMP OPTIONS ISSUE 5 CHARGE OUTPUT AC POWER SUPPLY 7 OTHER DSE9000 CHARGE BOOST INPUT N C VOLT FREE CHARGE FAIL OUTPUT 1 1 COMPATIBLE WITH ALL DSE M...

Page 68: ...ection needed Boost mode is operated by connecting the BOOST terminals together for instance with an external switch or timer circuit This will raise the battery charger floating voltage by 0 8V DC Ca...

Page 69: ...E9260 24V 10A 0 75kg 0 85kg Mounting type DIN rail or chassis mounting Din rail type EN 50022 35mm type only Mounting holes Suitable for M4 Mounting hole centres 142mm x 128mm 5 59 x 5 0 Input voltage...

Reviews: