background image

PG9984(P)/PG8984(P)/PG4984(P)

PowerG Wireless Dual Technology Mirror 

PIR Motion Detector Installation 

Instructions

Overview

The PG9984(P)/PG8984(P)/PG4984(P) are 2-way wireless
PIR/ Pet immune motion detectors utilizing Target Specific
Imaging™ to distinguish between human beings and pets
weighing up to 18 kg (40lb) while reduces false alarms by using
True Motion Recognition™. Built-in link quality indicators
reduce installation time by eliminating the need for the installer
to physically approach the control panel. The detectors also
have combined Fresnel and cylindrical optics that reach up to
15 meters (49 ft) and are equipped with wall creep zone protec-
tion.

Note:

 Pet immunity feature has not been evaluated to UL 639

or ULC-S306-03 due to the feature not being addressed in
either standard.

Device Setup 

Caution!

 To be installed by service persons in indoor, non-haz-

ardous locations only. Risk of explosion if battery is replaced
by an incorrect type. Observe polarity when installing batteries.
Dispose of used batteries according to the manufacturer's
instructions and according to local rules and regulations. Bat-
teries are to be replaced by service persons only.

Note: 

To ensure the continued operation of all wireless devices

after performing a system default, a global upload of all wire-
less programming via DLS is recommended before defaulting
the system. After completing the system default, download the
wireless programming. 

Legend

A. Screw Cover
B. LED
C. PIR Optical window
D. Enroll button (use a screwdriver to press the recessed but-

ton)

E. Battery
F.

Tamper switch

G. Horizontal view of coverage area
H. Vertical view of coverage area
I.

Microwave coverage

Note:

 Back tamper switch is required for UL commercial bur-

glary installations.

Install the battery

1. On the indicated location, lift the screw cover upward using

your thumb.

2. Loosen the screw and open the cover in the direction shown

by the arrow.

3. Insert a screwdriver into the slot shown and then push down-

ward to separate the base from the cover.

4. Insert battery while observing polarity.

Note: 

When manually programming wireless devices, if a

device has been powered up for more than 48 hours it cannot be
enrolled into the system until the device has been tampered and
restored. When programming the panel using the Quick Enroll
procedure follow the steps detailed in Enroll the Device into the
System.

Note: 

After restoring a low battery trouble the system may take

up to 5 minutes to clear the trouble.

Enroll the Device into the System

To quick enroll:
1. On a keypad press [*] [8] [Installer Code] [804] [000].
2. Press and hold the device enroll button until the LED lights

steady and then release the enroll button while the LED is
still lit. A confirmation message then appears on the keypad.

3. Press [*] key to confirm ID.
4. Enter [3 digit zone #].
5. Enter [3 digit zone type].
6. Enter [1 digit partition #] for all desired partitions and press

[#]. If using a menu based configuration you can scroll to the
desired partitions and press [*] to toggle the partition.

7. On an LCD keypad enter the label by using word library.
To pre-enroll:
1. Remotely configure the unique ID number into the system.

For more information see the HS2MHOST manual.

2. When on-site, press the device enroll button.

Note: 

If the wireless device has been powered for more then 48

hours without being enrolled, tamper and restore the device to
enroll it.

Perform a placement test

Note:

 Perform walktest at least once a year. 

Before permanently mounting any wireless device, temporarily
mount the device and perform a Placement test.
1.

Tamper the 
device by 
opening the 
cover.

2.

Restore the 
tamper. The 
device now 
enters 
Placement 
test mode 
for 15 min-
utes.

3.

Trip the 
device and 
the red LED 
blinks once 
to identify 
that a signal 
is being sent to the receiver and then blinks three times to 
identify the signal strength. To perform a walk test, walk 
across the far end of coverage pattern in both directions. 
The following table indicates received signal strength indi-
cation. 

IMPORTANT! 

Only GOOD or STRONG signal strengths are

acceptable. If you receive a POOR signal from the device, re-
locate it and re-test until a GOOD or STRONG signal is
received. 

Note:

 For UL/ULC installations, only STRONG signal levels

are acceptable. After installation verify the product functional-
ity in conjunction with the compatible receivers HSM2HOST9,
HS2LCDRF(P)9, HS2ICNRF(P)9 and PG9920.

Note:

 For detailed placement instructions refer to the control

panel Reference Guide.

Mount the Device

The PowerG Series wireless PIR Motion detectors shall be
installed and used within an environment that provides the pol-
lution degree max 2 and overvoltages category II. 

• Keep away from heat sources.
• Do not expose to air drafts.
• Do not install outdoors.
• Avoid direct sunshine.
• Keep wiring away from power cables.
• Do not install behind partitions.
• Mount on solid stable surface.

Installation Notes:

 Do not obscure the detector field of view

with large objects, such as furniture. Install in position such that
expected intruder motion is perpendicular to the zones of detec-
tion. Mount further than 5ft. from fluorescent light fixture
employing two fluorescent tubes minimum rated 40 W.

Important!

 The PGx984 detector is immune to activity below

1 m (3ft) from 38 kg (85 lb) animals. Above the 1 m (3 ft)
height limit, the detector is immune to 19 kg (42 lb) animals.
Pet immunity  decreases as the animal gets closer to the detec-
tor. Select a mounting location that minimizes potential close
proximity of animals. 

Note:

 Pet immunity feature has not been verified by UL/ULC.

WARNING!

 To comply with FCC and IC RF exposure compli-

ance requirements, the PIR detector should be located at a dis-
tance of at least 20 cm from all persons during normal
operation. The antennas used for this product must not be co-
located or operated in conjunction with any other antenna or
transmitter.
To Mount the Device
Identify your mounting height and desired detector range.
Using the table below determine if you are to use mounting
holes x or y. 

Note:

 Mounting flat or in a corner requires using different

mounting holes. Mount using the supplied screws.

Configuration

To enter the wireless configuration section enter [804][Zone
Number].

Device Toggles

Selections

LED Operation

Specifications

GENERAL

Detector Type: 

Dual element low-noise pyroelectric sensor

Lens Data

No. of Beam Elements:

 18x3=54 far parabolic mirror seg-

ments

No. of Curtain Elements:

 18

MW Coverage

Maximum:

 15 m (49 ft) / 90°

Medium:

 10 m (33 ft) / 90°

Minimum:

 5 m (16 ft) / 90°

Note: 

For UL/ULC listed installations the following settings 

are required: 

MW coverage:

 Maximum

Event counter:

 High Sensitivity

Pet Immunity (PGx984P):

 Up to 18 kg (40 lb)

ELECTRICAL

Sensor Type:

 K Band Doppler module: 24 GHz 

Internal Battery:

 3V Lithium battery, type CR-123A con-

sumer grade, UL or equivalent listed, RoHS compliant. Dispose 
of used batteries according to local regulations.

Note:

 For UL installations use Panasonic, Sanyo, GP or Varta 

only. 

Nominal Battery Capacity:

1450 mA/h

Battery Life (for typical use):

 minimum one year, typical 5-8 

years (not verified by UL/ULC)

Low Battery Threshold: 

2.5 V

FUNCTIONAL

True Motion Event Verification: 

2 remote selections - 1 

(OFF) or 2 (ON) motion events

Verification Alarm Period: 

2 seconds

WIRELESS

Frequency Band (MHz): 

CE Listed PG4984: 433MHz; CE/

EN listed PG8984: 868MHz; FCC/IC/UL/ULC listed PG9984: 
912-919 MHz

Communication Protocol: 

PowerG

Supervision: 

Signaling at 4-min. intervals

Tamper Alert: 

Reported when a tamper event occurs and in 

any subsequent message, until the tamper switch is restored

MOUNTING

Height:

 1.8 – 3.0 m (6 - 10 ft)

Installation Options - 

Surface or corner

ACCESSORIES

PGBRACKET-1: Surface mounted swivel bracket, adjustable 
30° down and 45° left/45° right.
PGBRACKET-2: PGBRACKET-1 with a corner adapter

PGBRACKET-3: PGBRACKET-1 with a ceiling adapter

Note:

 UL did not evaluate the product with the use of brackets.

ENVIRONMENTAL

RFI Protection:

 > - 20 V/m up to 2000 MHz, excluding inband 

frequencies

Temperature range:

 -10ºC to +55ºC (UL/ULC only verified the 

range 0ºC-49ºC)

Relative Humidity:

 up to max. 93%RH, non-condensing

PHYSICAL

Size (H x W x D):

 115 x 60 x 48 mm (4-1/2 x 2-5/16 x 1-15/

16”)

Weight (with battery):

 90 g (3oz).

Color:

 White

COMPATIBLE RECEIVERS

433MHz Band: HSM2HOST4; HS2LCDRF(P)4;HS2IC-
NRF(P)4; PG4920
868MHz Band: HSM2HOST8; HS2LCDRF(P)8; HS2IC-
NRF(P)8;PG8920
912-919MHz Band: HSM2HOST9; HS2LCDRF(P)9; HS2IC-
NRF(P)9; PG9920
Note: Only devices operating in band 912-919MHz are UL/
ULC listed.

UL/ULC Notes

Only models PG9984, PG9984P operating in the frequency 
band 912-919MHz are UL/ULC listed. The PG9984, PG9984P 
has been listed by UL for commercial and residential burglary 
applications and by ULC for residential burglary applications in 
accordance with the requirements in the Standards UL 639 and 
ULC-S306 for Intrusion Detection Units.
For UL/ULC installations use these device only in conjunction 
with compatible DSC wireless receivers: HSM2HOST9, 
HS2LCDRF(P)9, HS2ICNRF(P)9 and PG9920. After installa-
tion verify the product functionality in conjunction with the 
compatible receiver used.

Europe: The PG4984/PG4984P and PG8984/
PG8984P are compliant with the RTTE require-
ments - Directive 1999/5/EC of the European Par-
liament and of the Council of 9 March 1999. The

PG8984/PG8984P is certified to the following standards:
EN50131-2-4, EN50131-1 GRADE 2, CLASS II, EN50131-6
Type C. Certification covers only the 868 MHz variant of this
product. According to EN 50131-1:2006 and A1:2009, this
equipment can be applied in installed systems up to and includ-
ing Security Grade 2, Environmental Class II. UK: The PG8984
is suitable for use in systems installed to conform to
PD6662:2010 at Grade 2 and environmental class 2 BS8243
The Power G peripheral devices have two- way communication
functionality, providing additional benefits as described in the
technical brochure. This functionality has not been tested to
comply with the respective technical requirements and should
therefore be considered outside the scope of the product’s certi-
fication.

PG9984(P)/PG8984(P)/PG4984(P)

Instructions d'installation du détecteur de 

mouvement IPR, miroir, double 

technologie sans fil PowerG

Vue d'ensemble

Les PG9984(P)/PG8984(P)/PG4984(P) sont des détecteurs de
mouvement IPR/insensibles aux animaux, bidirectionnels, sans
fil, qui arrivent à faire la distinction entre des êtres humains et
des animaux d'un poids de 18 kg (40lb) max. grâce à la technol-
ogie Target Specific Imaging™ tout en réduisant les fausses
alarmes grâce à la technologie True Motion Recognition™. Les
indicateurs de qualité de liaison intégrés réduisent les temps
d'installation en supprimant la nécessité de l'installateur d'être
physiquement à proximité de la centrale. Les détecteurs sont
munis également d'optiques combinées cylindriques et de Fres-
nel qui atteignent une portée de 15 mètres (49 pieds) max. et
possèdent une détection au ras du mur.

Remarque : 

La fonction d'insensibilité aux animaux n'a pas été

évaluée pour les normes UL 639 ou ULC-S306-03 parce qu'elle
n'est pas abordée par les deux normes.

Réglage du dispositif 

C

B

A

D
E
F

1

2

3

4

LED response

Signal Strength 

Green LED blinks

STRONG 

Orange LED blinks

GOOD 

Red LED blinks

POOR 

No blinks

No communication

G

H

I

Height

Mounting Holes

10ft 3.0m

9

2.7

y

y

y

y

8

2.4

y

y

y

x

7

2.1

y

y

x

x

6

1.8

y

x

x

x

6

9

12 15m

Range

15

30

45

60ft

[001][01]

Alarm LED - Default [Y]

Enables the devices LED to activate when an alarm
event occurs.

[001][04]

Supervision - Default [Y]

Enables supervision of the device.

[003]

Hightraffic Shutdown - Default [01]

x

y

x

y

Activating this feature helps conserve battery power 

when the system is disarmed by configuring a reporting 

timer. When motion is detected, the device transmits an 

alarm to the receiver and will not report any further 

events until the timer expires. Any motion detected 

during the configured period will be reported once the 

timer expires. No Delay causes the device to report an 

alarm each time the detector is tripped.
[01] Detector Dis-

abled (while dis-

armed)

[02] No Delay

[03] 5 second 
delay

[04] 15 second 
delay

[05] 30 second 
delay

[06] 1m delay

[07] 5m delay

[08] 10m delay

[09] 20m delay

[10] 60m delay

[016]

Event counter - Default [002]

Alarm activates after a configured number of events 
have been detected.
Key in activities 
001-002

LED Indications

Event

Red LED blinks

Stabilization (warm-up 60 
sec)

Red LED on 0.2 sec.

Tamper open / close

Red LED blinks twice

One quad PIR detection in 
diagnostic mode

Red LED on 2 sec.

Intruder alarm

Yellow LED on 

AM detection – Testing 
mode

Yellow LED blinks slowly (0.2 
sec. ON, 30 sec. OFF)

AM detection – Normal 
mode

D-304673

Summary of Contents for PG9984(P)

Page 1: ...on enter 804 Zone Number Device Toggles Selections LED Operation Specifications GENERAL Detector Type Dual element low noise pyroelectric sensor Lens Data No of Beam Elements 18x3 54 far parabolic mirror seg ments No of Curtain Elements 18 MW Coverage Maximum 15 m 49 ft 90 Medium 10 m 33 ft 90 Minimum 5 m 16 ft 90 Note For UL ULC listed installations the following settings are required MW coverage...

Page 2: ...aux animaux PGx984P 18 kg 40 lb max DONNÉES ÉLECTRIQUES Type de capteur Module Doppler Bande K 24 GHz Batterie interne Pile au lithium de 3 V de type CR 123A grand public homologuée UL ou équivalent conforme RoHS Jetez au rebut les piles usagées selon la réglementation locale Remarque Pour les installations UL utilisez uniquement les piles Panasonic Sanyo Gp ou Varta Capacité nominale de la batter...

Page 3: ...orme a RoHS Deseche las baterías usadas de acuerdo con la reglamen tación local Nota Para instalaciones UL use solamente Panasonic Sanyo GP o Varta Capacidad nominal de la batería 1450 mA h Vida de la batería para uso típico mínima de un año por lo general 5 a 8 años no verificado por UL ULC Umbral de batería baja 2 5 V FUNCIONALES Verificación de evento de movimiento verdadero 2 selec ciones a di...

Page 4: ...icação de evento Movimento Real 2 seleções remotas 1 OFF ou 2 ON eventos de movimento Período do alarme de verificação 2 segundos SEM FIO Faixa de Frequência MHz PG4984 com classificação CE 433MHz PG8984 com classificação CE EN 868MHz PG9984 com classificação FCC IC UL ULC 912 919MHz Protocolo de Comunicação PowerG Verificação Assinalando em intervalos de 4 min Alerta de Bloqueio Reportado sempre ...

Page 5: ...cation qui n ont pas été expressément approuvés par Digital Security Controls peuvent annuler le droit de l utilisateur à se servir de cet équipement IMPORTANT À LIRE ATTENTIVEMENT Le logiciel DSC acheté avec ou sans Produits et Composants est protégé par le droit d auteur et il est acheté conformément aux modalités du contrat de licence Ce Contrat de licence d utilisation CLU est une entente léga...

Page 6: ...ores de movimento podem detectar movimento somente dentro das áreas designadas como mostrado nas suas respectivas instruções de instalação Eles não podem discriminar entre intrusos e ocupantes internos Os detectores de movimento não oferecem proteção da área volumétrica Eles têm múltiplos feixes de detecção e o movimento pode somente ser detectado em áreas não obstruídas cobertas por estes feixes ...

Reviews: