5.8

Listen To All

When the PC5928 enters the Talk/Listen-In mode, it can be programmed to initiate in one of
two ways. If the Listen “To All stations While On Line” option is enabled, all stations will turn
on. If the option is disabled, only the stations that are in alarm will turn on. This option only
affects how the PC5928 initiates the Talk/Listen-In session. All stations remain accessible
through use of the telephone command keys.

All zones follow this functionality regardless of their definition.

Listen To All Stations When On Line...................Section [30], Option [2]

5.9

Page Listens To All

Enabling this feature will allow all stations which hear pages to respond without answering. If
the page is answered by pressing the Page/Answer button, normal page activity will take
place. If the page is not answered, it will time out after 30 seconds.

Page Listens To All...................Section [30], Option [3]

5.10

Doorbell Listens To All

Enabling this feature will allow all stations which hear doorbell pages to respond without
answering. As well, visitors initiating the doorbell page will be heard on all other stations which
hear pages. If the doorbell page is answered by pressing the Page/Answer button, normal page
activity will take place. If the doorbell page is not answered, it will time out after 30 seconds.

Doorbell Listens To All...................Section [30], Option [4]

5.11

Telephone Ring Mask

Any station type can be enabled to sound a ringing tone when an incoming call is detected.
If the Telephone Ring Mask is disabled for a station, the ringing tone will not sound, but the
telephone call can still be answered.

The telephone ring mask overrides the general broadcast mask.

Telephone Ring Mask...................Section [60]

5.12

Doorstrike Activation Mask

There may be situations when a station should not activate the doorstrike feature. If the
Doorstrike Activation Mask option is disabled for a station, it will not be able to activate the
doorstrike feature.

The Doorstrike Activation Mask should not be enabled for stations programmed
as Doorbox 1 or Doorbox 2.

Doorstrike Activation Mask...................Section [70]

5.13

Doorstrike Option PGM Programming

This section is used to program which PGM type will be activated on the PC5010 when the
doorstrike feature is used.

Doorstrike PGM Option Programming...................Section [72]

P R O G R A M  D E S C R I P T I O N S

firealarmresources.com

Summary of Contents for PC5928

Page 1: ... Call to the In House Phones 7 3 11 Call Waiting 7 3 12 User Help Keypad Function keys 7 3 13 Music Input 8 3 14 Voice Verification 8 Section 4 Programming 8 Section 5 Program Descriptions 5 1 Station Definitions 9 5 2 Zone Port Assignment 9 5 3 Keypad Port Assignment 9 5 4 Broadcast Mask 9 5 5 Alarm Follower 9 5 6 Talk Listen In 10 5 7 Talk Listen In Operation 11 5 8 Listen To All 12 5 9 Page Lis...

Page 2: ...dule Each station has a separate microphone and speaker Each station must be home run to the interface module using shielded 22 gauge 4 conductor wire Each station can be used to initiate or receive pages answer incoming calls answer the doorbell monitor rooms or sound an alarm follower PC5921EXT Exterior Audio Station The PC5921EXT Exterior Audio Station is housed in a gray fade resistant case de...

Page 3: ...be done from any Power832 keypad Refer to the Audio Interface Programming Worksheets for program items and options Helpful Installation Tips Feedback If an intercom station appears to be exhibiting feedback noise check the following for potential causes Microphone Remove the backplate The microphone and holder are located in the bottom left corner Ensure that the microphone is pushed fully into th...

Page 4: ...he drain wire of the shield to the COM terminal on the PC5928 module or the black terminal of the station make sure the drain wire of the shield does not short anything on the back of the board but not both Refer to the diagram below Avoiding Audio Station Interference Noise The Keybus wiring and several different electrical devices fluorescent lighting etc may induce noise onto the intercom wires...

Page 5: ... panel the following steps must be taken Step 1 At a keypad enter 8 Installer Code to enter Installer Programming Step 2 Press 902 to enable supervision The panel will automatically search for all modules on the system Press to exit Installer Programming The search takes approximately 1 minute From this point on if any modules are removed from the system a Supervisory trouble will be generated Ste...

Page 6: ...iated by accident pressing the Page Answer button a second time will cancel the Page 3 4 Do Not Disturb To avoid receiving pages doorbox calls or incoming phone calls a station can be put on Do Not Disturb To do this press the Do Not Disturb button on the station The red light on the station will come on solid to indicate the unit is in Do Not Disturb mode To take a station off Do Not Disturb pres...

Page 7: ...b button The red light on the station will go out 3 9 Answering Incoming Calls When an incoming call is detected the PC5928 will sound a ringing tone on all stations which are enabled to sound the tone unless on Do Not Disturb To answer the call the user must press the Page Answer button for 1 second Once the call is answered the audio channel will operate the same as it does for a Page The call w...

Page 8: ...connecting the audio source to a microphone input one side of the source to the mic input and the other side to ground The music input must be programmed in the port definitions enter installer s programming section 802 sub section 01 Enter the digits 05 in the appropriate port definition To turn on the music input enter user programming 6 Master Code then press 7 key To turn off the music input f...

Page 9: ...e alarm Zone Port Assignments must be programmed even if zone alarms are not used Tampers Openings and Closings and all other events will not function if there are NO ports assigned here Zone Port Assignment Section 10 to 13 5 3 Keypad Port Assignment This section is used to program which keypad is closest to which station This is used with the Identified Voice Prompted Help feature described in S...

Page 10: ...zones programmed as silent will not initiate a Talk Listen In session Only a Listen In session can occur Keypad Panic alarms will activate the Listen In feature if the Panic Keys Alarm option is enabled Keypad Auxiliary alarms will activate the feature if the Auxiliary Keys Alarm option is enabled Listen in will be initiated if a Duress code is entered at a keypad and the Duress Alarm option is en...

Page 11: ... Once the central station has established the audio link there are several commands available to them for audio control Commands are the touch tone digits 0 through 9 and Additional commands may be programmed as Mode Keys which are two button entries The central station may already be using other Talk Listen In equipment Because of this the PC5928 offers flexible programming for the various comman...

Page 12: ... will be heard on all other stations which hear pages If the doorbell page is answered by pressing the Page Answer button normal page activity will take place If the doorbell page is not answered it will time out after 30 seconds Doorbell Listens To All Section 30 Option 4 5 11 Telephone Ring Mask Any station type can be enabled to sound a ringing tone when an incoming call is detected If the Tele...

Page 13: ... 11 l_____l_____l Zone 13 l_____l_____l Zone 15 l_____l_____l Zone 10 l_____l_____l Zone 12 l_____l_____l Zone 14 l_____l_____l Zone 16 12 Zone Port Assignments Zones 17 24 Enter the nearest Intercom Station Number 01 07 00 Not Used Default 00 l_____l_____l Zone 17 l_____l_____l Zone 19 l_____l_____l Zone 21 l_____l_____l Zone 23 l_____l_____l Zone 18 l_____l_____l Zone 20 l_____l_____l Zone 22 l_...

Page 14: ..._l Option 08 For Future Use Audio Control Telephone Key Functions 00 Key Not Used 09 Terminate Session 01 Talk To All Speakers 10 For Future Use 02 For Future Use 11 Cancel First Keypress 03 High Gain Listen To All 12 For Future Use 04 For Future Use 13 Zone Select 0 3 only 05 For Future Use 14 Increment Selected Microphone Input 06 Low Gain Listen To All 15 Decrement Selected Microphone Input 07 ...

Page 15: ... Disabled OFF l________l Option 08 Zone 16 Alarm Enabled Disabled 52 Third Audio Control Options Default Option ON Option OFF OFF l________l Option 01 Zone 17 Alarm Enabled Disabled OFF l________l Option 02 Zone 18 Alarm Enabled Disabled OFF l________l Option 03 Zone 19 Alarm Enabled Disabled OFF l________l Option 04 Zone 20 Alarm Enabled Disabled OFF l________l Option 05 Zone 21 Alarm Enabled Dis...

Page 16: ... Telephone Ring Enabled Disabled OFF l________l Option 06 Port 5 Telephone Ring Enabled Disabled OFF l________l Option 07 Port 6 Telephone Ring Enabled Disabled OFF l________l Option 08 Port 7 Telephone Ring Enabled Disabled 70 Doorstrike Activation Mask Default Option ON Option OFF OFF l________l Option 01 For Future Use OFF l________l Option 02 Port 1 Enabled to Activate Doorstrike Disabled OFF ...

Reviews: