6
The keypad sounds 4 quick beeps and the
Armed light turns off.
The Ready light turns on to indicate that the
PC5502Z2 is waiting for the information to
be entered.
If the section number entered is invalid the keypad will sound a two second error
tone.
3. Enter the information required to complete the section programming:
If you are programming a data entry section (for example section [25] Master code),
enter the required number of decimal digits. When you have entered the maximum
number of digits in the programming section the keypad sounds 4 quick beeps, the
Ready light turns off, and the Armed light turns on.
If you are programming a toggle option section (an option you can turn on or off),
press [1] to turn the option on or off. The “1” light will be on if the option is on, and
off if the option is off. When the option is set correctly, press [#]. The keypad sounds
4 quick beeps, the Ready light turns off, and the Armed light turns on.
4. After you are finished programming a section, you can enter another 2-digit section
number to program the next section.
5. When you are finished programming, press [#]. The keypad will exit Installer’s pro-
gramming.
NOTE:
After you exit from Installer’s programming, all bypassed zones will be
cleared (unbypassed).
4.2 Setting up PC5502Z2 Zones and Zone Options
Each PC5502Z2 keypad can supervise two zones. By default, zone 1 is programmed as
(01) Delay 1, and zone 2 is programmed as (02) Instant. If you need to change how the
zones operate, you can select from these zone definitions:
(00) Null Zone:
The zone is vacant. Program unused zones as null zones.
(01) Delay 1:
This zone type is normally used for entry/exit doors. It can be violated dur-
ing the exit delay time without causing an alarm. Once the exit delay has expired, open-
ing the zone will start the entry delay timer. During the entry delay time, the keypad
buzzer will sound steadily to advise the user that the system should be disarmed. If the
panel is disarmed before the entry time expires, no alarm will be generated.
(02) Instant:
This zone type will cause an instant alarm if it is violated when the panel is
armed. Typically, this zone is used for windows, patio doors or other perimeter zones,
and glass break detectors.
(03) Interior:
This zone will not cause an alarm if violated during the entry delay. If the
zone is violated before the entry delay has begun, it will cause an instant alarm. Typically,
this zone is used for interior protection devices, such as motion detectors.