Programming Section Descriptions

If you will be connecting the PC5400 to a PC5010, PC5015, PC1555 or PC580 control panel, access the
PC5400 programming sections at a system keypad by entering [*][8][Installer's Code][803]. Then enter
the 2-digit number of the section you want to program.

If you will be connecting the PC5400 to a PC1575, access the PC5400 programming sections at a
system keypad by entering [*][8][Installer's Code][87]. Then enter the 2-digit number of the section you
want to program.

Section [06], Option [2]: AC Communications

To change from standard DVACS (150 baud) to AC communications protocol (300 baud) program this
option as ON.

Section [07]: Subsystem Number

Program the DVACS Subsystem number in this section.

Section [08]: Group Number

Program the DVACS Group number in this section.

Section [09]: Panel DVACS Identifier Code

Program the DVACS ID code in this section.

Sections [10-17], and [50-52]: DVACS Reporting Codes

Program the DVACS reporting codes in these sections (see Appendix A: ADT DVACS Transmission
Table):

• To have the PC5400 transmit a pre-programmed code from the internal table, leave the

programming at the default value FF.

• To prevent the PC5400 from reporting an event, program the code as 00.

• To have the PC5400 transmit a different code, program a value from 01-FE.

Sections [18-27]: Transmission Options

To prevent the PC5400 from transmitting a group of reporting codes (e.g. zone troubles or zone trouble
restorals) program the appropriate option as OFF. All options are ON by default.

Sections [28-35]: Zone Assignments

The programming in these sections tells the PC5400 which partitions each zone is assigned to (on
control panels which are capable of partitioning) and/or which zones in active use.
If the PC5400 is connected to a control panel using partitions, make sure that the zone/partition
assignments match those programmed in the control panel.

If the PC5400 is connected to a control panel without partitions, you must still program these sections:
for each used zone on the control panel, turn ON the option that assigns the zone to partition 1.

Sections [36-39]: Zone Definitions

Make sure that the zone definitions match those programmed in the control panel.

NOTE: If you change any of the above options from the default settings, test the PC5400 to make sure
it is operating as desired.

Summary of Contents for PC5400

Page 1: ...ming Worksheets 6 PC5010 PC5015 PC5008 PC1555 PC580 Programming Sections 7 PC1575 Programming Sections 15 Appendix A ADT DVACS Transmission Table 18 Appendix B Special Events for PC5010 v1 03 ADTU 22...

Page 2: ...2 Notes...

Page 3: ...Diagram included in this manual RED BLK YEL and GRN Terminals Connect the RED BLK YEL and GRN terminals to the RED BLK YEL and GRN terminals on the control panel Refer to the control panel Installati...

Page 4: ...4 PC5400 Hookup Diagram...

Page 5: ...grammed code from the internal table leave the programming at the default value FF To prevent the PC5400 from reporting an event program the code as 00 To have the PC5400 transmit a different code pro...

Page 6: ...ystem keypad by entering 8 Installer s Code 87 Then enter the 2 digit number of the section you want to program See page 15 for PC1575 programming sections Program the following sections for all contr...

Page 7: ...I Zone 18 FF I____I____I Zone 22 FF I____I____I Zone 19 FF I____I____I Zone 23 FF I____I____I Zone 20 FF I____I____I Zone 24 13 Zone 25 32 Reporting Codes Default Default FF I____I____I Zone 25 FF I__...

Page 8: ...I____I Option 1 Zone Alarms Disabled ON I____I Option 2 Zone Alarm Restorals Disabled ON I____I Option 3 Zone Troubles Disabled ON I____I Option 4 Zone Trouble Restorals Disabled ON I____I Option 5 Z...

Page 9: ...ore Disabled ON I____I Option 7 PC5204 Output 1 Fail Disabled ON I____I Option 8 PC5204 Output 1 Restore Disabled 22 Fifth Transmission Options Default Option On Option Off ON I____I Option 1 PC5204 S...

Page 10: ...ed ON I____I Option 7 Late to Close Disabled ON I____I Option 8 Downlook Module Remote Trigger Disabled 26 Ninth Transmission Options Default Option On Option Off ON I____I Option 1 Battery Trouble Di...

Page 11: ...artition 1 OFF I____I Option 8 Zone 16 is on Partition 1 Zone 16 is not on Partition 1 30 Partition 1 Zone Assignments 17 24 Default Option On Option Off OFF I____I Option 1 Zone 17 is on Partition 1...

Page 12: ...on Partition 2 OFF I____I Option 8 Zone 16 is on Partition 2 Zone 16 is not on Partition 2 34 Partition 2 Zone Assignments 17 24 Default Option On Option Off OFF I____I Option 1 Zone 17 is on Partitio...

Page 13: ...ntrol panels only 36 Zone 1 8 Definitions Default Default 01 I____I____I Zone 1 04 I____I____I Zone 5 03 I____I____I Zone 2 04 I____I____I Zone 6 03 I____I____I Zone 3 04 I____I____I Zone 7 03 I____I_...

Page 14: ...efault Default FF I____I____I Wireless Key 1 FF I____I____I Wireless Key 5 FF I____I____I Wireless Key 2 FF I____I____I Wireless Key 6 FF I____I____I Wireless Key 3 FF I____I____I Wireless Key 7 FF I_...

Page 15: ...porting Codes Default Default FF I____I____I Keypad 1 FF I____I____I Keypad 5 FF I____I____I Keypad 2 FF I____I____I Keypad 6 FF I____I____I Keypad 3 FF I____I____I Keypad 7 FF I____I____I Keypad 4 FF...

Page 16: ...f ON I____I Option 1 Keypad Supervisory Disabled ON I____I Option 2 Keypad Supervisory Restore Disabled ON I____I Option 2 Keypad Tamper Disabled ON I____I Option 4 Keypad Tamper Restore Disabled ON I...

Page 17: ...r Heat 21 24 Hour Latching Tamper 04 Interior 13 24 Hour Gas 05 Interior Home Away 14 24 Hour Hold Up 06 Delay Home Away 15 24 Hour Medical 07 Delayed 24 Hour Fire Hardwired 16 24 Hour Panic 08 Standa...

Page 18: ...See ADT DVACS ZONE REPORTING TYPES Zone xx Tamper Holdup See ADT DVACS ZONE REPORTING TYPES Zone xx Tamper Supervisory See ADT DVACS ZONE REPORTING TYPES Zone xx Tamper Other See ADT DVACS ZONE REPORT...

Page 19: ...38 Maintenance Number Closing By Keyswitch Zone id44CLp 44 Keyswitch Number Closing By Downloading id45CLp 45 Download Number Opening By User Code id OPp Auto Arm Cancellation CEp Opening By Maintenan...

Page 20: ...re PC59XX Supervisory UTx 8ST Default x 38 PC59XX Supervisory Restore URx ESCORT5580 Supervisory UTx 8ST Default x 39 ESCORT5580 Supervisory Restore URx PC5208 Supervisory UTxx 8ST Same as Untyped Zon...

Page 21: ...sory Restore ERxx PC5100 Tamper EAxx 4ST xx 42 PC5100 Tamper Restore ERxx The following events are not supported by ADT and will not be transmitted to the central station Expansion Mod Supervisory Alm...

Page 22: ...vents NOT Transmitted when using the PC5400 with the PC5010 v1 03 ADTU 2 Wire Smoke Alarm FAxx 1ST 2 Wire Smoke Alarm Restoral FRxx Default xx 33 Phone Number 1 FTC LT1 Phone Number 2 FTC LT2 Phone Nu...

Page 23: ...24HR NON ALARM UA 2ST UA 2ST UT 2ST UT 2ST UT 1ST UT 1ST 87 DELAY 24HR FA Wireless FT FT FT FT FA 1ST FA 1ST 88 STAND 24HR FA Wireless FT FT FT FT FA 1ST FA 1ST 1 Ignored by Control NORMALLY CLOSED SI...

Page 24: ...d is and shall be in lieu of any and all other warranties whether expressed or implied and of all other obligations or liabilities on the part of Digital Security Controls Ltd This warranty contains t...

Page 25: ...o n H o w e v e r t h e r e i s n o g u a r a n t e e t h a t i n t e r f e r e n c e w i l l n o t o c c u r i n a p a r t i c u l a r i n s t a l l a t i o n I f t h i s equipment does cause interfe...

Page 26: ...to the System Installation Manual for information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer 1998 Digital Security Control...

Reviews: