DUAL-EOL / ZONE DOUBLER
DEVICE ACTIVATED
OPEN LOOP
SHORT ON LOOP
(OPENS CONTACTS)
INPUT POINT ASSIGNMENT
ARMED
DISARMED
ARMED
DISARMED
ARMED
DISARMED
00 NULL
-
-
-
-
-
-
01 DELAY 1
BA
✱
2ST
1
BA
✱
2ST
BT
✱
2ST
BA
✱
1ST
BT
✱
1ST
02 DELAY 2
BA
✱
2ST
1
BA
✱
2ST
BT
✱
2ST
BA
✱
1ST
BT
✱
1ST
03 INSTANT
BA
✱
2ST
1
BA
✱
2ST
BT
✱
2ST
BA
✱
1ST
BT
✱
1ST
04 INTERIOR
BA
✱
2ST
1
BA
✱
2ST
BT
✱
2ST
BA
✱
1ST
BT
✱
1ST
05 INTERIOR HOME/AWAY
BA
✱
2ST
1
BA
✱
2ST
BT
✱
2ST
BA
✱
1ST
BT
✱
1ST
06 DELAY HOME/AWAY
BA
✱
2ST
1
BA
✱
2ST
BT
✱
2ST
BA
✱
1ST
BT
✱
1ST
07 DELAY 24HR FIRE
FT
FT
FT
FT
FA
✱
1ST
FA
✱
1ST
08 STANDARD 24 HR FIRE
FT
FT
FT
FT
FA
✱
1ST
FA
✱
1ST
09 24HR SUPV BUZZER
ST
✱
1ST
ST
✱
1ST
ST
✱
1ST
ST
✱
1ST
SS
✱
2ST
SS
✱
2ST
10 24HR SUPERVISORY
SS
✱
2ST
SS
✱
2ST
ST
✱
2ST
ST
✱
2ST
ST
✱
1ST
ST
✱
1S
11 24HR BA
BA
✱
2ST
BA
✱
2ST
BA
✱
2ST
BT
✱
2ST
BA
✱
1ST
BT
✱
1ST
12 24HR HOLDUP
HA
✱
2ST
HA
✱
2ST
HT
✱
2ST
HT
✱
2ST
HT
✱
1ST
HT
✱
1ST
13 24HR GAS
UA
✱
2ST
UA
✱
2ST
UT
✱
2ST
UT
✱
2ST
UT
✱
1ST
UT
✱
1ST
14 24HR HEAT
UA
✱
2ST
UA
✱
2ST
UT
✱
2ST
UT
✱
2ST
UT
✱
1ST
UT
✱
1ST
15 24HR MEDICAL
MA
✱
2ST
MA
✱
2ST
MT
✱
2ST
MT
✱
2ST
MT
✱
1ST
MT
✱
1ST
16 24HR PANIC
BA
✱
2ST
BA
✱
2ST
BT
✱
2ST
BT
✱
2ST
BT
✱
1ST
BT
✱
1ST
17 24HR EMERGENCY
MA
✱
2ST
MA
✱
2ST
MT
✱
2ST
MT
✱
2ST
MT
✱
1ST
MT
✱
1ST
18 24HR SPRINKLER
FA
✱
2ST
FA
✱
2ST
FT
✱
2ST
FT
✱
2ST
FT
✱
1ST
FT
✱
1ST
19 24HR WATER
SS
✱
2ST
SS
✱
2ST
ST
✱
2ST
ST
✱
2ST
ST
✱
1ST
ST
✱
1ST
20 24HR FREEZE
UA
✱
2ST
UA
✱
2ST
UT
✱
2ST
UT
✱
2ST
UT
✱
1ST
UT
✱
1ST
21 24HR LATCHING TAMPER
BA
✱
2ST
BA
✱
2ST
BT
✱
2ST
BT
✱
2ST
BT
✱
1ST
BT
✱
1ST
22 MOMENTARY KEYSWITCH
-
-
BT
✱
2ST
BT
✱
2ST
BT
✱
1ST
BT
✱
1ST
23 MAINTAINED KEYSWITCH
-
-
BT
✱
2ST
BT
✱
2ST
BT
✱
1ST
BT
✱
1ST
24 LINKS ANSWER
-
-
-
-
-
-
25 INTERIOR DELAY
BA
✱
2ST
1
BA
✱
2ST
BT
✱
2ST
BA
✱
1ST
BT
✱
1ST
26 24HR NON-ALARM
UA
✱
2ST
UA
✱
2ST
UT
✱
2ST
UT
✱
2ST
UT
✱
1ST
UT
✱
1ST
87 DELAY 24HR FA (Wireless)
FT
FT
FT
FT
FA
✱
1ST
FA
✱
1ST
88 STAND 24HR FA (Wireless)
FT
FT
FT
FT
FA
✱
1ST
FA
✱
1ST
1 - Ignored by Control
NORMALLY CLOSED
SINGLE EOLR
CROSS
OPEN
INPUT POINT ASSIGNMENT
ARMED
DISARMED
ARMED
DISARMED
ARMED
DISARMED
00 NULL
-
-
-
-
-
-
01 DELAY 1
BA
✱
2ST
1
BA
✱
2ST
1
BA
✱
2ST
1
02 DELAY 2
BA
✱
2ST
1
BA
✱
2ST
1
BA
✱
2ST
1
03 INSTANT
BA
✱
2ST
1
BA
✱
2ST
1
BA
✱
2ST
1
04 INTERIOR
BA
✱
2ST
1
BA
✱
2ST
1
BA
✱
2ST
1
05 INTERIOR HOME/AWAY
BA
✱
2ST
1
BA
✱
2ST
1
BA
✱
2ST
1
06 DELAY HOME/AWAY
BA
✱
2ST
1
BA
✱
2ST
1
BA
✱
2ST
1
07 DELAY 24HR FIRE
-
-
FA
✱
1ST
FA
✱
1ST
FT
FT
08 STANDARD 24 HR FIRE
-
-
FA
✱
1ST
FA
✱
1ST
FT
FT
09 24HR SUPV BUZZER
-
-
SS
✱
2ST
SS
✱
2ST
ST
✱
1ST
ST
✱
1ST
10 24HR SUPERVISORY
SS
✱
2ST
SS
✱
2ST
SS
✱
2ST
SS
✱
2ST
SS
✱
2ST
SS
✱
2ST
11 24HR BA
BA
✱
2ST
BA
✱
2ST
BA
✱
2ST
BA
✱
2ST
BA
✱
2ST
BA
✱
2ST
12 24HR HOLDUP
HA
✱
2ST
HA
✱
2ST
HA
✱
2ST
HA
✱
2ST
HA
✱
2ST
HA
✱
2ST
13 24HR GAS
UA
✱
2ST
UA
✱
2ST
UA
✱
2ST
UA
✱
2ST
UA
✱
2ST
UA
✱
2ST
14 24HR HEAT
UA
✱
2ST
UA
✱
2ST
UA
✱
2ST
UA
✱
2ST
UA
✱
2ST
UA
✱
2ST
15 24HR MEDICAL
MA
✱
2ST
MA
✱
2ST
MA
✱
2ST
MA
✱
2ST
MA
✱
2ST
MA
✱
2ST
16 24HR PANIC
BA
✱
2ST
BA
✱
2ST
BA
✱
2ST
BA
✱
2ST
BA
✱
2ST
BA
✱
2ST
17 24HR EMERGENCY
MA
✱
2ST
MA
✱
2ST
MA
✱
2ST
MA
✱
2ST
MA
✱
2ST
MA
✱
2ST
18 24HR SPRINKLER
FA
✱
2ST
FA
✱
2ST
FA
✱
2ST
FA
✱
2ST
FA
✱
2ST
FA
✱
2ST
19 24HR WATER
SS
✱
2ST
SS
✱
2ST
SS
✱
2ST
SS
✱
2ST
SS
✱
2ST
SS
✱
2ST
20 24HR FREEZE
UA
✱
2ST
UA
✱
2ST
UA
✱
2ST
UA
✱
2ST
UA
✱
2ST
UA
✱
2ST
21 24HR LATCHING TAMPER
BA
✱
2ST
BA
✱
2ST
BA
✱
2ST
BA
✱
2ST
BA
✱
2ST
BA
✱
2ST
22 MOMENTARY KEYSWITCH
-
-
-
-
-
-
23 MAINTAINED KEYSWITCH
-
-
-
-
-
-
24 LINKS ANSWER
-
-
-
-
-
-
25 INTERIOR DELAY
BA
✱
2ST
1
BA
✱
2ST
1
BA
✱
2ST
1
26 24HR NON-ALARM
UA
✱
2ST
UA
✱
2ST
UA
✱
2ST
UA
✱
2ST
UA
✱
2ST
UA
✱
2ST
87 DELAY 24HR FA (Wireless)
-
-
FA
✱
1ST
FA
✱
1ST
FT
FT
88 STAND 24HR FA (Wireless)
-
-
FA
✱
1ST
FA
✱
1ST
FT
FT
1 - Ignored by Control
Appendix D: ADT DVACS Zone Reporting Types