![DSC PC5400 Installation Manual Download Page 20](http://html1.mh-extra.com/html/dsc/pc5400/pc5400_installation-manual_2534354020.webp)
20
PC5010 Event Description --------------------- ADT Transmission ------- Comments
Aux. Power Supply Trb. Alarm ------------------ UTxx --------------------------- Default xx = 36
Aux. Power Supply Trb. Restore ---------------- URxx ---------------------------
DLS Lead In ------------------------------------------ RB1 ----------------------------
DLS Lead Out ---------------------------------------- RS1 -----------------------------
Installer Lead In ------------------------------------- id39SI ------------------------- Only 1 Installer, always 39
Installer Lead Out ----------------------------------- id39SO ------------------------
ADT On Premise (by maintenance) ------------ id38SI -------------------------
ADT Off Premise (by maintenance) ------------ id38SO ------------------------
Keypad x Supervisory ----------------------------- ITx
✱
8ST ----------------------- x = 1 - 8
Keypad x Supervisory Restoral ----------------- IRx ------------------------------
Keypad x Tamper ----------------------------------- IAx
✱
4ST ----------------------
Keypad x Tamper Restoral ----------------------- IRx ------------------------------ Same as Supervisory Restore
Zone Expander x Supervisory ------------------- ETx
✱
8ST ---------------------- x = 1 - 6
Zone Expander x Supervisory Restoral ------- ERx -----------------------------
Zone Expander x Tamper ------------------------- EAx
✱
4ST ---------------------
Zone Expander x Tamper Restoral ------------ ERx ----------------------------- Same as Supervisory Restore
PC5132 Supervisory ------------------------------- ETx
✱
8ST ---------------------- Default x = 7
PC5132 Supervisory Restore -------------------- ERx -----------------------------
PC5132 Tamper ------------------------------------- EAx
✱
4ST ---------------------
PC5132 Tamper Restore -------------------------- ERx ----------------------------- Same as Supervisory Restore
PC59XX Supervisory ------------------------------- UTx
✱
8ST --------------------- Default x = 38
PC59XX Supervisory Restore -------------------- URx ----------------------------
ESCORT5580 Supervisory ------------------------ UTx
✱
8ST --------------------- Default x = 39
ESCORT5580 Supervisory Restore ------------ URx ----------------------------
PC5208 Supervisory ------------------------------- UTxx
✱
8ST -------------------- Same as Untyped Zones
Trouble
PC5208 Supervisory Restore -------------------- URxx --------------------------- Default xx = 34, After last
zone #
PC5208 Tamper ------------------------------------- UTxx
✱
4ST --------------------
PC5208 Tamper Restore -------------------------- URxx --------------------------- Same as Supervisory Restore
PC5204 Supervisory ------------------------------- UTxx
✱
8ST -------------------- Default xx = 35
PC5204 Supervisory Restore -------------------- URxx ---------------------------
PC5204 Tamper ------------------------------------- UTxx
✱
4ST --------------------
PC5204 Tamper Restore -------------------------- URxx ---------------------------
PC5204 AC Fail -------------------------------------- UTxx ---------------------------
PC5204 AC Restore -------------------------------- URxx ---------------------------
PC5204 Batt Trouble ------------------------------- UTxx
✱
16ST ------------------
PC5204 Batt Restore ------------------------------- URxx ---------------------------
PC5204 Output 1 Fail ------------------------------ UTxx ---------------------------
PC5204 Output 1 Restore ------------------------ URxx ---------------------------
PC5204 Circuit Trouble --------------------------- UTxx
✱
2ST --------------------
PC5204 Circuit Restore --------------------------- URxx ---------------------------
PC5400DV Tamper --------------------------------- UTx
✱
4ST --------------------- Default x = 37
PC5400DV Tamper Restore ---------------------- URx ----------------------------
PC5400DV Supervisory Alarm ------------------- UTx
✱
8ST ---------------------
PC5400DV Supervisory Restore ---------------- URx ----------------------------
Alternate Communicator Tamper --------------- UTxx
✱
4ST -------------------- Default xx=41
Alternate Comm.Tamper Restore --------------- URxx ---------------------------
Alternate Comm. Supervisory Alarm ----------- UTxx
✱
8ST --------------------
Alternate Comm. Supervisory Restore -------- URxx ---------------------------