Section 4: Programming Options
Default:
000.000.000.000
Valid range:
000.000.000.000 to 255.255.255.255
Panel's Preferred DNS Server
This section is used to program the name of the preferred
Domain Name System server.
Note:
To use the panel’s preferred DNS server, the option
LAN/WLAN Obtain IP Address must be set to Static IP
address.
Default:
000.000.000.000
Valid range:
000.000.000.000 to 255.255.255.255
Panel's Alternate DNS Server
This section is used to program the name of an alternate
Domain Name System server to be used if the preferred
DNS server is unavailable.
Note:
To use the panel’s alternate DNS server, the option
LAN/WLAN Obtain IP Address must be set to Static IP
address.
Default:
000.000.000.000
Valid range:
000.000.000.000 to 255.255.255.255
WLAN SSID
This section is used to program a network name (unique
identifier) for the panel.
Default:
None
Valid range:
Alphanumeric
WLAN Client Control
This option is used to control WiFi client mode.
Default:
Enabled
Valid range:
Enabled/Disabled
WLAN Security Type
This option is used to select which encryption protocol the
system uses to secure the wireless network.
Default:
WPA2 PSK AES
Valid range:
WPA PSK TKIP
WPA PSK AES
WPA PSK TKIP AES
WPA2 PSK TKIP
WPA2 PSK AES
WPA2 PSK TKIP AES
WLAN Security Key
This section is used to program a password for the Wi-Fi net-
work.
Default:
None
Valid range:
32 character ACCII
Time Zone
This option defines the time zone that the alarm system will
operate in.
Default: US Eastern
Valid
range:
US-Alaska, US-Aleutian, US-Arizona, US-Central, US-Eastern, US-
Hawaii, US-Indiana-East, US-Indiana-Starke, US-Michigan, US-Moun-
tain, US-Pacific, US-Samoa, CA-Atlantic, CA-Central, CA-Eastern,
CA-Mountain, CA-Newfoundland, CA-Pacific, CA-Saskatchewan, CA-
Saskatchewan-East, CA-Yukon
Time zone is set automatically by ADC based on the install-
ation address provided in the customer setup.
4.4 Central Monitoring Station
Programming Options
The following section provides descriptions of all pro-
gramming options for communications between the iotega
and the central monitoring station.
Communication Path
Use this option to select the method by which the panel com-
municates to the central monitoring station. Choose one of
the following:
Cellular: The system communicates to the central monitoring
station via cellular connection only.
Ethernet and Cellular: The system communicates to the cent-
ral monitoring station via Ethernet as the primary path and
cellular as the secondary path.
Default:
None
Valid range:
Cellular, Ethernet and Cellular
4.4.1 Other Communicator Related
Options
Cellular Test Transmission Time
Enter a 4-digit number (0000-2359) using the 24-hour clock
format (HHMM) to set the time of day a cellular test trans-
mission is sent. Programming a value of 9999 disables the
test transmission time.
Note:
The internal date and time will automatically be pro-
grammed when the unit communicates with the primary
receiver.
Default:
9999
Valid range:
0000 to 2359, 9999 to disable
Cellular Test Transmission Cycle
This option is used to program how often, in minutes, cel-
lular test transmissions are sent. Once the initial test trans-
mission is sent, all future test transmissions are offset by the
programmed number of minutes.
Default:
0 minutes.
Valid range:
000000 to 999999 minutes
- 17 -