Section 4: Programming Options
Auto Alarm Scroll Option
When this option is enabled, the keypad scrolls auto-
matically and displays all alarms when the bell is active or
when an alarm is in memory while armed.
Default:
Enabled
Valid range:
Read-only
Local Clock Display Option
When this option is enabled, the keypad displays the time
and date when not in use.
Default:
Enabled
Valid range:
Read-only
4.7.2 User Configuration Options
This section describes programming options for configuring
system users.
User Partition Assignment
This section is used to assign system user 2-100 to an avail-
able partition. Users may be assigned to multiple partitions.
Basic/Standard users may only assign new users to par-
titions they themselves have permission to access.
Default:
1
Valid range:
1, 2, 3, 4, All
User Access Code (Pin)
This section is used to program a 4-digit code used to
access the panel. Each user requires a code. Duplicate
codes are not permitted.
Default:
Blank
Valid range:
0000 to 9999
User Access Level
Each system user is assigned an access level that determ-
ines the features they can use. All codes are 4-digit decimal
entries. Duplicate codes are not permitted.
The following access levels may be available on your panel:
Master User
Has access to all system functionality. These functions
include:
l
Bypass/unbypass zones
l
Chime enable/disable
l
View troubles
l
View alarms in memory
l
Create new users (via user app)
l
Initiate a system test
l
Update Panel WiFi (client mode) SSID & password
l
Adjust keypad settings sucha as buzzer tone and
volume, display contrast and brightness
l
Assign wireless keys to users
Level 0: Professional Installer
Has permission to enable WPS mode (to enable local pro-
gramming access to the panel via the installer app) and also
initiate phone test.
Level 1: Supervisor/Administrator
Users assigned to this level have similar privileges to the
Master Code user but are limited based on the partition
assignment. This user can perform the following actions on
the partitions they are assigned to:
l
Arm/Disarm
l
Bypass/Unbypass
l
Enable/disable chime
l
Access home automation menu
l
View troubles, initiate a system test
l
Select a display language
l
View the event buffer
l
Program zone labels
l
Update WiFi SSID and password
l
Create new users
l
Program a duress code
l
Program user labels
Supervisor users can only add, edit or delete users
assigned to the same partitions as they are.
Level 2: Basic/Standard User
Has permission to access basic security functions, including:
l
Arm/disarm
l
Bypass/unbypass zones
l
Enable/disable chime
l
View system troubles
l
View alarm in memory
Level 3: Maintenance/Guest
Users assigned to this level are limited to an assigned par-
tition and have reduced system access. These functions
include:
l
Arm/disarm
l
Enable/disable chime
l
View system troubles
Duress code:
Has access to all features of Basic/Standard user, including:
l
Arm/disarm
l
Bypass/unbypass zones
When this code is used for any function, a duress code
event will be generated.
User Name (label)
This option is used to program a system user name.
Default:
Blank
Valid range:
32 character ACSII
4.7.3 Wireless Siren Configuration
Options
The following section provides descriptions of all wireless
siren programming options.