[011] Keypad Input/Output Programming
Zone / PGM Number Default 000 |_____|_____|_____|
[012] Local PGM Output Pulse Activation Time
|_______|_______| Minutes (00-99)
|_______|_______| Seconds (00-99)
[021] First Keypad Options
Default
Opt. ON
OFF
ON
|____| 1
Fire Key Enabled
Fire Key Disabled
ON
|____| 2
Medical Key Enabled
Medical Key Disabled
ON
|____| 3
Panic Key Enabled
Panic Key Disabled
ON
|____| 4
Display Access Code When Pro-
gramming
Display Xs When Programming
Access Codes
NOTE: For EN50131-1/EN50131-3 compliant systems, section [021], options 1 and 2 shall be OFF.
[022] Second Keypad Options
Default
Opt. ON
OFF
ON
|____| 1
Local Clock Display ON
Local Clock Display OFF
OFF
|____| 2
Local Clock Displays 24-hr
Clock Displays AM/PM
ON
|____| 3
Auto Alarm Mem Scroll ON
Auto Alarm Mem Scroll OFF
ON
|____| 4
For Future Use
For Future Use
OFF
|____| 5
Power LED Enabled
Power LED Disabled
ON
|____| 6
Power LED AC Present ON
Power LED AC Present OFF
ON
|____| 7
Alarms Displayed While Armed
Alarms Not Displayed While Armed
OFF
|____| 8
Auto-Scroll Open Zones ON
Auto-Scroll Open Zones OFF
[023] Third Keypad Options
Default
Opt. ON
OFF
OFF
|____| 1
Armed LED Power Save
Armed LED Off in Sleep Mode
ON
|____| 2
Keypad Status Shows Stay Arm
Keypad Status Shows Stay/Away Arm
OFF
|____| 3
5th Terminal is PGM Output
5th Terminal is Zone Input
OFF
|____| 7
Local Display of Temperature
No Local Display of Temperature
OFF
|____| 8
Low Temperature Warning Enabled
Low Temperature Warning
Disabled
[030] Downloaded LCD Message
|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|
|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|_____|
NOTE: Clock display (Section [022], Option 1) must be enabled.
[031] Downloaded LCD Message Duration
Default: 000 |_____|_____|_____|
(Valid entries are 000-255, 000=Unlimited Msg Display)
This number represents the number of times the downloaded message must be cleared before it is per-
manently removed. This message can be cleared by pressing any key.
[041] Indoor Temperature Zone Assignment
Default: 000 |_____|_____|_____| (Valid entries are 000-128)
[042] Outdoor Temperature Zone Assignment
Default: 000 |_____|_____|_____| (Valid entries are 000-128)
[101]-[228] Door Chime for Zones
Default: 01 |_____|_____|
The keypad can be programmed to make up to four different chime sounds for individual zones.
(e.g., for Zone 1, enter section [101], for Zone 2 enter section [102]).
01 6 beeps
04 Alarm Tone (4s duration)
02 Bing bing tone
05 Zone Name
03 Ding dong tone
[991] Reset Keypad Programming to Factory Defaults
1. Press [*][8][Installer Code].
2. Enter [991].
3. Use the [<][>] keys to scroll to the applicable keypad.
4. Press [*] to select the keypad.
5. Re-enter [Installer Code].
6. Press [*] to reset the selected keypad to factory defaults
Keypad Symbols
Table 4: Keypad Display Symbols
1
2
7
8
9
12
10
3
11
13
4
5
6
14
15
16
17
1
Memory – Indicates that alarms are in memory.
10
Chime – Turns on when Door
Chime is enabled and off when
Door Chime is disabled.
2
Fire – Indicates that fire alarms are in memory.
11
Away – Indicates that the panel
is armed in away mode.
3,4,5
Clock Digits – These digits indicate the hour and
minutes when the local clock is active, and also
identify the zone when the OPEN or ALARM
icons are active. These digits scroll one zone per
second from the lowest zone number to the
highest when scrolling through zones.
12
Stay – Indicates that the panel is
armed in stay mode.
13
Night – Indicates that the panel is
armed in night mode.
6
1 to 8 – These numbers display toggles or digits
in binary while they are needed.
14
Ready Light (green) – If the
Ready light is on, the system is
ready for arming.
7
Bypass – Indicates that there are zones auto-
matically or manually bypassed.
15
Armed Light (red) – If the Armed
light is on, the system has been
armed successfully.
8
Open – When zones are opened, this icon will
turn on and the open zones are displayed.
16
System Trouble – Indicates that a
system trouble is active.
9
Program – If the system is in Installer’s or
User’s Programming, or the keypad is busy, this
icon flashes. If an access code is required while
accessing star menus, this LED is on steadily to
indicate that the code is required.
17
AC – Indicates that AC is
present at the main panel.