background image

IS9212iLW

Features:

•  Flush Mount, Single Gang
•  Illuminated Backlit Keys
•  Keypad Programmable
•  Keypress Feedback via Built-In Sounder
•  Bi-Color Red/Green LED Indicates Relay Status
•  Yellow LED Indicates Program Mode
•  120 Users
•  Single Use Codes
•  Lockout Users
•  Passage/Toggle Codes
•  10 to 30 Volt DC Operation
•  12 to 24 Volt AC Operation
•  2 Amp Main Relay
•  Remote Trigger Input (REX)
•  2 Year Warranty

Product Description:

The 212iLW keypad features a single-relay output to control any
device requiring an on/off switch. The output is timed or latched and
operated by a user’s PIN code. Additionally, the 212iLW keypad
provides basic keyless entry by controlling a door locking device
where security is not an issue.

The 212iLW style keypads are designed for both indoor and outdoor flush 
mount applications. The electronics are conformal coated in the  
manufacturing process in order to provide this level of application  
flexibility. In addition, each keypad uses hardened keys to assure long-term, 
high-quality performance.

Each keypad contains illuminated clear keys that make operation in low 
light situations easy and accurate. iLW style keypads mount to any standard 
single-gang electrical box or directly to any wall.

Specifications:

Parameter

Range/Description

Voltage

10–30 VDC, 12-24VAC (Auto-Adjusting)

Current

93mA @ 10VDC; 158mA @ 30VDC, 148mA @ 12VAC; 198mA @ 24VAC

Environment

For Indoor and Outdoor Use

Temperature Tolerance

-20° F to 130° F (-28° C to 54° C)

Dimensions

5 1/8” H x 3 3/8” W x 5/8” D

Main Relay (Form C)

Contact Rating: 2A @ 30VAC/DC

REX Input

Normally Open Dry Contact

Door Position Input

Normally Closed Dry Contact

LEDs

Bi-Color Red/Green; Yellow

Default Keypad Settings

Parameter

Default Setting

Master Code

1234

Lock Output

Relay 1 ( Main relay )

Audio Alerts

Not assigned

REX

Triggers Lock Output

REX Operation

Always Triggers (regardless of Door Loop)

Error Lockout / Threshold

Enabled / 3 Attempts

Error Lockout Duration

10 seconds

Lock Output Time

5 seconds

Visual / Audio Keypress Feedback

Enabled

Auto-Entry

Disabled

User Lockout

Enabled

PCN13023 

R11/13CA

I N S T A L L A T I O N

9212iLW

Interior/Exterior Use Stand-Alone Keypad

©2013 RutheRfoRd contRols • www.RutheRfoRdcontRols.com

usA: 2517 sQuAdRon couRt, suIte 104, VIRGInIA BeAch, VA 23453 • cAnAdA: 210 sheARson cRescent, cAmBRIdGe, on  n1t 1j6 

 Phone • 1.800.265.6630 • 519.621.7651 • fAX: 1.800.482.9795 • 519.621.7939 • e-mAIl: [email protected]

Summary of Contents for 9212ilw

Page 1: ...tions easy and accurate iLW style keypads mount to any standard single gang electrical box or directly to any wall Specifications Parameter Range Description Voltage 10 30 VDC 12 24VAC Auto Adjusting Current 93mA 10VDC 158mA 30VDC 148mA 12VAC 198mA 24VAC Environment For Indoor and Outdoor Use Temperature Tolerance 20 F to 130 F 28 C to 54 C Dimensions 5 1 8 H x 3 3 8 W x 5 8 D Main Relay Form C Co...

Page 2: ...Wire Color Signal name 1 Red V Keypad Power 2 Black V Keypad Power 3 White Black Not Used 4 White Yellow Not Used 5 Brown Remote Trigger REX 6 White Orange Loop Common REX and Door Loop 7 White Door Loop Monitor 8 Green Main Relay Normally Open 9 Blue Main Relay Common 10 Gray Main Relay Normally Closed Wiring the Keypad to a Maglock Fail Safe Use the following steps to connect the keypad to a Mag...

Page 3: ...vents the REX from re triggering when the door is open Figure 6 Wiring a REX Button and Door Contacts Testing the Keypad After installing the keypad RCI recommends that you perform the keypad self test once a year to ensure that the keypad works properly 1 To perform the self test with the unit powered up press the following keys on the keypad 7890 123456 If all 12 keypresses are accepted the keyp...

Page 4: ...nd their codes no longer work to gain access A lockout is removed by entering the same lockout code If another lockout code in another user location is entered the lockout user location level is set to the new lockout user location The master code and emergency users can t be locked out The current lockout is cleared when program mode is entered Lock out activated is indicated by two double beeps ...

Page 5: ...r Lockout Duration Value 1 255 default 5 1 255 default 5 1 50 default 3 1 255 default 10 Error Lockout When enabled the keypad keeps track of the number of consecutive invalid codes entered including attempts to access program mode When the threshold is reached the yellow LED turns on solid and the keypad no longer responds to key presses for the programmed time duration The count is reset by ente...

Page 6: ...e verify voltage is correct at power supply The master code does not work Perform the programming mode loopback and reset the master code using the programming command No LEDs are lit on the keypad Power is not reaching the keypad Using a voltmeter confirm that there is voltage at the keypad on the red and black wires If there is no voltage at the keypad verify that there is voltage at the power s...